The example depicts the recess kit fixed on the
length sides only. The installer is responsible for
ensuring product is installed in a structurally
sound configuration.
238mm (9.4")
Minimum - 180mm (7
.1")
(Fr
om glas
s surf
ac
e)
995mm (39.2") - [2300W]
1430 (56.3") - [3400W]
TERMINAL BOX END
CLEARANCE
CLEARANCE
ZONE
CEILING CUTOUT LENGTH
CUTOUT WIDTH
WARNING
The appliance shall, under no circumstances, be
covered with insulating material or similiar material.
Minimum vertical ceiling space clearance between
the ceiling recess box and ceiling surface must be
180mm (7.1").
Minimum clearance measured from the terminal box
end to the nearest surface must be 200mm (7.9").
Minimum clearance from the ceiling cutout and the
nearest wall must be 500mm (19.7").
Minimum distance between heaters measured from
edge of ceiling cut out must be 500mm (19.7”)
with exception for Australia/New Zealand minimum
2000mm (78.7”)*.
Minimum distance between the heater surface and
finished floor is 2400mm (94”).
*
Note:
Under AS/NZ 60335.2.30:2015 clause 7.12.1 specifies the distance
between the sides of the heater and the sides and any adjacent
ceiling recessed heater shall not be less than four times the
minimum distance specified for the distance between the sides of
the heater and any building element adjacent to it.
!
Standard Versions
Ensure that the heating unit is not directly exposed to
rain or water contact. For the longest product life and to
maintain product appearance, mount the heater under
cover and protect from rain and weather.
CEILING CUTOUT & CLEARANCE ZONES
Marine Versions
In a salt-air environment, such as near an ocean,
corrosion occurs more quickly than normal. Stainless
316 has been used in the Marine configuration. Salt
spray should be cleaned from the heater and recess kit
immediately - while the heater and recess kit should
undergo cleaning fortnightly to ensure maximum
longevity. Use a qualified technician to check yearly for
corroded areas and remove from service when heater
safety is compromised.
MINIMUM 240mm (9.4”)
GAP BETWEEN JOISTS
CEILING
JOIST
500mm
(19.7")
MINIMUM WALL
CLEARANCE FROM TRIM
2400mm (94")
2400mm (94")
SIDE VIEW
FRONT VIEW
CEILING
FLOOR
261mm (10.3")
FLOOR
ROOM CLEARANCE AND OVERALL DIMENSIONS
ABO
VE FINISH FL
OOR (AFF)
MINIMUM CLEARANCE
ABO
VE FINISH FL
OOR (AFF)
MINIMUM CLEARANCE
ISOMETRIC VIEW DEPICTING LOW CLEARANCE RECESS KIT
INSTALLATION SETUP OPTIONS
500mm
(19.7")
MINIMUM WALL
CLEARANCE FROM
TRIM
TRIM LENGTH
1039mm (40.9”) - [2300W]
1475 (58.1”) - [3400W]
TRIM WIDTH
175mm (6.9")
MAX
PRODUCT
HEIGHT
200mm (7.9")