LEAK TESTING
3
All factory-made connections have been thoroughly tested
for gas leaks and the burner has been flame tested.
However, shipping and handling may have loosened a gas
fitting.
AS A SAFETY PRECAUTION:
•
TEST ALL FITTINGS FOR LEAKS BEFORE USING
YOUR INFRARED SIDE BURNER.
•
TEST THE CYLINDER VALVE FOR LEAKS EACH
TIME THE CYLINDER IS FILLED.
•
TEST FOR LEAKS EVERY TIME YOU DISCONNECT
AND RECONNECT A GAS FITTING.
•
DO NOT SMOKE!
•
NEVER TEST FOR LEAKS WITH A LIGHTED
MATCH OR OPEN FLAME.
•
TEST FOR LEAKS OUTDOORS.
TO TEST FOR LEAKS
1.
Assemble the infrared side burner per the
assembly instructions
. See page 8.
2. Check that all control knobs are turned to "OFF".
3. Prepare a soap solution of one-part water, one-part
liquid detergent.
4. Open gas source.
5. Light the infrared side burner. See lighting on page 4.
6. Brush the soap solution on each connection.
7. A leak is identified by a flow of bubbles from the area of
the leak.
8. If a leak is detected, close the gas source, turn side
burner control to “OFF”. Tighten the connection and
retest (Step 5).
9. If the leak persists, contact your barbecue dealer for
assistance. Do not attempt to operate appliance if a
leak is present.