IOM BiRotor 3” to 6” R03
8 Specifi cations
The following specifi cations apply to the meter unless otherwise noted.
WARNING
Do NOT operate this instrument in excess of the specifi cations listed. Failure to heed this warning could
result in serious injury and/or damage to the equipment.
9 Receipt of Shipment
When you receive your meter, inspect the outside
of the packing case for damage which may have
incurred during shipping.
Damage incurred during
shipment is the responsibility of the carrier and is
not part of the factory warranty.
If the package is in
good condition remove the envelope containing the
packing list and carefully remove the meter and
all components included in the shipment from the
packing case. Inspect for damaged or missing parts,
referring to the packing list, and prior to discarding
the packing material. If Items are missing from your
shipment, contact your sales representative. Your
sales order number will be required.
If the packing case is damaged, notify the local
carrier immediately.
If the meter must be returned to
the factory for repair or replacement, a Returned Ma-
terials Report (RMR) must be included with the meter
or components. RMR forms may be obtained from
your sales representative or from the Product Service
Department. In addition to the RMR, a Material Safety
Data Sheet and a Decontamination Statement must
be included with Items being returned to the factory.
A Decontamination Statement is included in the
back of this manual (see page 30).
If the meter is removed from service it must be thor-
oughly drained and neutralized before it is packed for
shipment. Care must be taken to ensure that product
removed from the meter is disposed of in accordance
with all applicable local, state and federal regulations.
NOTE:
Place the meter on the inlet fl ange to completely
drain the the meter of fl uid.
The fl anges should be sealed to keep residual fl uid
from leaking out of the meter during transport. The
type of fl ange seal required will vary with the form of
transportation used. Contact the carrier for specifi c
instructions.
Materials of Construction
Housing
Welded steel construction combining steel castings and draw
steel plate.
Measuring Unit
Rotors
Three lobe, cast iron or four
fl uted, heat treated aluminum.
Rotor Shafts
Ground and polished nitralloy
Rotor Bearings
Stainless Steel
Body and End Covers
Nickel cast iron
Counter Base Plate
Body
Steel
O-Ring
Viton standard
Counter Base Drive Gears
Stainless Steel
Drive Shafts
Stainless Steel
Drive Shaft Ball Bearing
Stainless Steel
Connections
3”, 4”, or 6” ANSI Flange