24
Brocade VA-40FC Hardware Reference Manual
53-1001540-04
Maintaining the Brocade VA-40FC
3
2. Verify that the switch prompt displays on the terminal of a computer workstation connected to
the switch.
If there is no switch prompt when POST completes, press Enter. If the switch prompt still does
not display, try opening a Telnet session or accessing the switch through another management
tool. If this is not successful, the switch did not successfully complete POST. Contact your
switch supplier for repair.
3. Review the switch system log for errors. Any errors detected during POST are written to the
system log, accessible through the errShow command.
For information about all referenced commands, and on accessing the error log, refer to
Fabric OS
Administrator’s Guide
. For information about error messages, refer to the
Fabric OS Message
Reference Manual
.
Maintaining the Brocade VA-40FC
The Brocade VA-40FC does not require any regular physical maintenance and is designed for high
availability and to minimize the chance of failure. It includes diagnostic tests and field-replaceable
units, described in the following sections.
Installing an SFP
The Brocade VA-40FC only supports Brocade-branded SFPs. If you use an unqualified SFP, the
switchShow command output shows the port in a Mod_Inv state. Fabric OS also logs the issue in
the system error log.
Complete the following steps to install an SFP.
1. Making sure that the bail (wire handle) is in the unlocked position, place the SFP in the
correctly oriented position on the port, as shown in
.
2. Slide the SFP into the port until you feel it click into place; then close the bail.
Summary of Contents for VA-40FC
Page 1: ...53 1001540 04 31 May 2012 Brocade VA 40FC Hardware Reference Manual ...
Page 6: ...vi Brocade VA 40FC Hardware Reference Manual 53 1001540 04 ...
Page 40: ...28 Brocade VA 40FC Hardware Reference Manual 53 1001540 04 Managing the Brocade VA 40FC 3 ...
Page 60: ...46 Brocade VA 40FC Hardware Reference Manual 53 1001540 04 ...