![Brocade Communications Systems FWS624 Hardware Installation Manual Download Page 36](http://html1.mh-extra.com/html/brocade-communications-systems/fws624/fws624_hardware-installation-manual_2817379036.webp)
26
Brocade FastIron WS Hardware Installation Guide
53-1002188-01
Activating power to the device
2
DRAFT: BROCADE CONFIDENTIAL
FIGURE 24
Pin-out diagram for the RPS12 power supply.
Activating power to the device
After you complete the physical installation, you can activate power to the device.
2
1
10
3
4
5
6
7
8
9
11
12
13
14
15
16
17
18
-54 V
-54 V RTN
N. C.
RPS Present
Power Good
-54 V
-54 V
N. C.
N. C.
N. C.
12 V
12 V RTN
12 V
-54 V RTN
-54 V RTN
12 V RTN
RPS Type
RPS Power Good
TABLE 10
Port pin-out diagram for the RPS12 power supply
Pin
Name
Description
1, 2, 3
-54 V
-54 volts connection
4, 5, 6, 13
N.C.
No connection
7, 8
12 V
12 volts connection
9, 18
12 V RTN
12 volts return connection
10, 11, 12
-54 V RTN
-54 volts return connection
14
RPS Present
Indicates that a redundant power supply is attached and
functioning
15
RPS Type
Indicates either load-sharing or redundant mode
16
RPS Power Good
Indicates that power is being supplied to the redundant
power supply
17
Power Good
Connected device internal power supply status