HOW TO USE POWER BRUSH/WAND

WAND RELEASE

The power brush is not 
recommended for use on
bare floors. Wand release
pedal (

A

) on power brush

allows you to quickly 
disconnect wand and switch
to combination floor/rug tool
for use on bare floors.

POWER BRUSH NECK RELEASE

Push down power brush neck release pedal (

B

) to unlock

brush neck. Return the neck to the upright position for storage.

POWER BRUSH HEIGHT ADJUSTMENT

The icons (

D

) refer to the carpet pile

height. Select height by depressing
height adjustment pedal (

C

) to desired

position:

(Extra-Low),      (Low),

(Medium) or        (High).

H

EIGHT ADJUSTMENT LED INDICATORS

The LEDs show the carpet pile covered
by the selected height, e.g.: when

(High) is selected, all LEDs will be lit, since this height

covers all pile heights. So if      (Extra-Low) is selected, only the
lowest LED will be lit.

WAND LENGTH ADJUSTMENT

Extend (

E

) or shorten (

F

)

the wand to comfortable
work position by holding
the wand grip (

G

) in one

hand and sliding the upper
section (the one with the
prongs) with the other
hand.

FLOOR 

HEIGHT

B

C

D

F

E

A

G

CAUTION

Always pick up hard or sharp objects by hand
before using your power brush. Items such as pins,
hairpins, tacks, crayons, etc., may damage the
brush roll or may break the belt.

CAUTION

Always unlock brush neck before use.

AO0020

AD0022

AD0023

AD0024

EDGE CLEANER

Brush extends full width for effective edge cleaning along both
sides of nozzle. To operate, simply run cleaner along edge
board. Rubber bumper protects furniture and baseboards.

ELECTRONIC CIRCUIT BREAKER

The power brush is equipped
with an electronic circuit breaker
that protects the motor and the
belt if a too large object is
picked up accidentally.

If the power brush stops while
vacuuming, turn the power unit
off using handle. Release the
power brush from the wand
and turn it over to see if there is an obstruction. When brush
roll jam has been cleared, press the reset button (

H

) and 

connect the power brush back to the wand. Finally, turn the
power unit/power brush back on. If it fails to restart or continues
to trip without any apparent reason, the power brush must be
serviced by an authorized service center.

CLEANING AND STORAGE

CLEANING BRUSH ROLL

In order to keep high cleaning efficiency and to prevent 
damage to your vacuum cleaner, the brush roll must be
cleaned every time the belt is changed.

The brush roll must also be cleaned according to the following
schedule:

V

ACUUM CLEANER USE

C

LEAN BRUSH ROLL

Heavy (used daily)

Every week

Moderate (2-3 times per week)

Every month

Light (1 time per week)

Every 2 months

Check and remove hair, string and lint build-up frequently in
the brush roll and end cap areas. Remove any dirt or debris in
the belt path and in the brush roll areas.

CLEANING HOUSING

To keep the power brush housing clean, it can be wiped with
a damp cloth and a mild soap solution, then thoroughly dried.
Never use any type of chemical as they can damage the housing.

STORAGE

1.

Ensure that hose and power cord are disconnected from
wall inlet before unplugging power brush.

2.

Disconnect hose handle from wand.

3.

Always keep hose neatly coiled when not in use.

4.

When not in use, the power brush should be stored in a
clean, dry place.

WARNING

Disconnect electrical supply before servicing or
cleaning the unit. Failure to do so can result in 
electrical shock or personal injury from cleaner
suddenly starting.

!

AD0030

H

Summary of Contents for VX12000C

Page 1: ...R GUIDE BROAN NUTONE CANADA INC MISSISSAUGA ONTARIO WWW BROAN CA 1 888 882 7626 30042323 rev K CENTRAL VACUUM POWER UNIT REGISTER YOUR PRODUCT ONLINE AT WWW BROAN CA FOR RESIDENTIAL USE ONLY VISIT WWW BROAN CA FOR THE CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS ...

Page 2: ... unit by pulling on cord To unplug grasp the plug not the cord 11 Store your cleaner indoors in a clean dry area 12 Any servicing other than that recommended in this manu al should be performed by an authorized service facility 13 We recommend that your unit be inspected by a specialized technician once a year OPERATION The power unit is located away from the everyday living areas of your home usu...

Page 3: ...PARTS 15 WARRANTY 16 TABLE OF CONTENTS CENTRAL VACUUM SYSTEM INSTALLATION INSTRUCTIONS Please visit www broan ca for the Central Vacuum System Installation Instructions including System Planning and Layout General Installation Installation in New Construction Installation in Existing Construction Tubing System Assembly Final System Check Also including the practical and easy to use Vacusweep Inlet...

Page 4: ... or mounting plate tubing ring Twist both pieces while joining them to evenly spread the glue Allow 5 minutes for the cement to set in flexible tubing SECURE WIRE TO TUBING The low voltage power wiring is run along with the tubing Use electrical tape to secure the wire to the tubing Tape the wire approximately every 12 to 18 MAKING THE WALL INLET CUTOUT The wall inlet should be located 18 on cente...

Page 5: ...imensions 4 Using the provided mounting screws secure the mounting bracket on the wall through two upper and two lower mounting holes 5 Hang power unit onto wall mounting bracket Ensure both upper and lower mounting openings on the back of the power unit are engaged with corresponding wall bracket fingers Pull the power unit down to secure 6 Open the door located on the front of the power unit Ens...

Page 6: ... into a wall ceiling or concealed space in the house It is recommended to vent the vacuum exhaust air to the outside of the house Exterior vented exhaust lines should be terminated using Model V142 wall caps DIMENSIONAL CHART EXHAUST B CENTER OF EXHAUST TO MOUNTING BRACKET HOLES A OVERALL HEIGHT C INTAKE AD0004A Models VX3000C VX6000C VX12000C A 369 16 399 16 399 16 B 11 11 11 C 107 8 107 8 107 8 ...

Page 7: ... 5 depending on the model No adapter should be used with this appliance TO OTHER INLETS NOTE INLET LEADS TO BE CONNECTED TO POWER UNIT TERMINALS USING CRIMP CONNECTORS AND LOW VOLTAGE WIRE HARNESS INLET LEADS MODEL V133 18 2 WIRE POWER UNIT POWER CORD NORTH AMERICA AC ELECTRIC OUTLET GROUND PIN NEMA 6 20R 240 VOLT GROUNDED OUTLET BOX AE0010A CRIMP CONNECTORS LOW VOLTAGE WIRE LOW VOLTAGE WIRE HARNE...

Page 8: ... 3 AO0022 OPERATING HANDLE SWITCH LOW VOLTAGE HOSE The switch will turn power unit ON OFF DUAL VOLTAGE HOSE Switch on the right position Central vacuum mode with power brush Switch on the left position Central vacuum mode without power brush Switch in the center Power unit is turned OFF AD0025 A A AD0026 AD0033 AD0032 CONNECTING HOSE CONT D DUAL VOLTAGE HOSE In addition to connecting into wall inl...

Page 9: ...K BUTTON HOSE HANDLE PRONGS WAND WAND RECEPTACLE RECEPTACLE WAND GRIP WAND RELEASE PEDAL POWER BRUSH NECK RELEASE PEDAL HOSE HANDLE RELEASE BUTTON QUICK CONNECTOR AO0019 AO0020 AO0021 WAND AND HOSE COMPATIBILITY WAND PART NO 08949 VACUUM HOSE PART NOS 32DVB 32DVN AND BN32DV HOSE HANDLE CAUTION Always check underside of product for any obstructions prior to use WARNING Never leave electric power br...

Page 10: ...er that protects the motor and the belt if a too large object is picked up accidentally If the power brush stops while vacuuming turn the power unit off using handle Release the power brush from the wand and turn it over to see if there is an obstruction When brush roll jam has been cleared press the reset button H and connect the power brush back to the wand Finally turn the power unit power brus...

Page 11: ... HOW TO CHANGE BRUSH ROLL Replace brush roll when brush roll brissles are worn to the base support bars level 1 Turn power brush over and using a Phillips no 2 screwdriver remove the 3 brush roll cover retaining screws Fig 6 and set aside 2 Remove brush roll cover Fig 7 3 To free brush roll from base start by sliding the belt side end and pull brush roll sideways 1 Once disengaged from housing lif...

Page 12: ...t turns red it is time to empty the pail see CONTROL PANEL DIAGRAM A below EMPTYING THE DEBRIS PAIL Your power unit has a permanent filter that is self cleaning under normal conditions The filter protects the motor and stops small dirt particles from escaping to the outside of the power unit The filter cleans itself by moving up when the power unit starts and dropping down when the unit is turned ...

Page 13: ...ptying the debris pail Simply brush filter clean If the filter is excessively soiled wash in a mild detergent and let it dry completely before reinstalling A FILTER REMOVAL Open the door located on the front of the power unit Reach inside the unit and remove both locking sleeves from the retaining hooks Carefully pull filter down to remove NOTE Broan model VX12000C has two secondary filters Ensure...

Page 14: ...ck all wall inlet covers to be sure they are closed and sealed tightly Inspect and remove any blockages 2 Power unit does not start or shuts off during normal operation with no LED showing red or illuminated Defective inlet Check other wall inlets Thermoprotector has been activated OR there is a tripped circuit breaker on the unit Blown fuse or tripped circuit breaker on house electrical panel Def...

Page 15: ...filter TS X X 8 10941217 Motor Chamber VS with foam and logo X 10941218 Motor Chamber TS with foam and logo X X 9 10941211 Top cap VS with logo X 10941213 Top cap TS with logo X X NOTE Order service parts by Part No not by Key No This part MUST be removed and installed by a qualified technician SERVICE PARTS REPLACEMENT PARTS AND REPAIRS In order to ensure your ventilation unit remains in good wor...

Page 16: ... REPAIR OR REPLACE AT BROAN NUTONE CANADA S OPTION SHALL BE THE PURCHASER S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY BROAN NUTONE CANADA SHALL NOT BE LIABLE FOR INCIDENTAL CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE Please do not return your unit to place of purchase Please visit www broan ca for your closest service center You may also cal...

Reviews: