VENTILATION FAN 

MODEL  QTXE150

TYPICAL 
INSTALLATIONS

Housing 
mounted to 

I

-joists.

Use I-joist 
spacer block 
(provided).

Housing mounted 
anywhere between 
trusses using 
hanger bars.

Housing 
mounted 
anywhere 
between 

I

-joists 

using 
hanger bars.

Housing 
mounted to 
joists.

Housing 
mounted 
anywhere 
between 
joists 
using 
hanger bars.

Housing 
mounted to 
truss.

PLAN THE INSTALLATION

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

ROOF CAP*

(with built-in

damper)

WALL CAP*

(with built-in

damper)

6-IN. ROUND

ELBOWS*

6-IN. ROUND

DUCT*

FAN

HOUSING

Seal gaps

around

housing.

Seal duct

joints with

tape.

Keep duct

runs short.

INSULATION

(Place around and

over fan housing.)

POWER

CABLE*

*Purchase

separately.

OR

The ducting from this fan to the outside of the building has a strong effect on the 
air flow, noise and energy use of the fan. Use the shortest, straightest duct routing 
possible for best performance, and avoid installing the fan with smaller ducts than 
recommended. Insulation around the ducts can reduce energy loss and inhibit 
mold growth. Fans installed with existing ducts may not achieve their rated airflow.

Summary of Contents for ULTRA SILENT QTXE150

Page 1: ...all prior warranties and is not transferable from the original consumer purchaser No Other Warranties This Limited Warranty contains the Company s sole obligation and your sole remedy for defective products The foregoing warranties are exclusive and in lieu of any other war ranties express or implied THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES ANDDISCLAIMSANDEXCLUDESALLWARRANTI...

Page 2: ...OKING AREA ROOF CAP with built in damper WALL CAP with built in damper 6 IN ROUND ELBOWS 6 IN ROUND DUCT FAN HOUSING Seal gaps around housing Seal duct joints with tape Keep duct runs short INSULATION Place around and over fan housing POWER CABLE Purchase separately OR The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use t...

Page 3: ...ng will be flush with finished surface of ceiling For 1 2 thick ceiling material position bottom of each mounting flange flush with the bottom of joist The housing mounts with four 4 screws or nails Screw or nail housing to joist through low est holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each ...

Page 4: ...14 Spacer 2 supplied 9 97020013 Hanger Bar Kit 5 Insert mask and finish ceiling Tape mask into housing Mask protects unit dur ing construction Remove before installing grille Install ceiling material Cut out around housing INSTALL MASK FINISH CEILING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate...

Page 5: ...atural del acabado i Productos en uso comercial o no residencial o j daños ocasionados por incendio inundación u otro caso fortuito Esta garantía cubre solamente Productos vendidos a clientes originales en los Estados Unidos por la Compañía o a distribuidores de EE UU autorizados por la Compañía Esta garantía sustituye todas las garantías anteriores y no es transferible del comprador consumidor or...

Page 6: ...ador integral TAPA DE PARED con amortiguador integral CODO REDONDO DE 6 PULG CONDUCTO REDONDO DE 6 PULG CUBIERTA DE VENTILADOR Selle los huecos alrededor de la cubierta Sellar las juntas con cinta Mantenga corre conducto corto AISLAMIENTO Puede ser colocado alrededor y sobre de la cubierta del ventilador Se compran por separado O CABLE DE ALIMENTACIÓN Los conductos desde este ventilador hacia el e...

Page 7: ...abada del techo Para techos de material de 1 2 de grueso posicione la parte inferior de cada soporte al ras con la parte inferior de cada viga INSTALE LA CUBIERTA Y EL CONDUCTO 2 Acople el conector del regulador de tiro conducto 3 Instale el conducto redondo de 6 pulgadas Conecte el conducto redondo de 6 pulgadas al conector del regulador conducto Extienda el conducto hacia una tapa de techo o tap...

Page 8: ...5 97020011 Conjunto del ventilador 6 97018530 Conjunto de la rejilla incluye la pieza con clave n o 7 7 99140208 Resorte de la rejilla se requieren 2 8 97018014 Separador se suministran 2 9 97020013 Juego de barra de suspensión 4 Conecte los cables eléctricos Extienda el cableado de la casa de 120 V CA al lugar de la in stalación Utilice una conexión aprobada por UL para afianzar el cableado de la...

Reviews: