background image

Page 3

 

 

VENTILATION FAN 

MODEL  QTXE150

1b.  Mount housing anywhere between 

trusses, joists, or 

I

-joists using hanger 

bars.

Sliding hanger bars are provided to allow for accurate positioning 

of housing anywhere between framing. They can be used on all 

types of framing (

I

-joist, standard joist, and truss construction) 

and span up to 24”.
Attach the MOUNTING CHANNELS to the housing using the 

SCREWS supplied. 

Extend HANGER 

BARS to the width of 

the framing.
Hold housing in place 

so that bottom edge of 

housing will be flush 

with finished surface 

of ceiling.  For 1/2” 

thick ceiling material, 

position bottom of 

each mounting flange 

flush with bottom of 

joist.

OR

INSTALL HOUSING & DUCT

1a. Mount 

housing to 

joist.

 

Hold housing 
in place so that 
bottom edge 
of housing will 
be flush with 
finished surface 
of ceiling. For 
1/2” thick ceiling 
material, position bottom of each mounting flange flush 
with the bottom of joist. The housing mounts with four (4) 
screws or nails. Screw or nail housing to joist through low-
est holes in each mounting flange,  then through highest 
holes. NOTE: Mounting to 

I-JOIST

 (shown) requires use 

of 

SPACERS

 (included) between the highest hole of each 

mounting flange and the I-joist.

2. Attach 

damper/duct 

connector.

3. Install 

6-inch round 

ductwork.

 

Connect 6-inch 

round ductwork 

to damper / duct 

connector. Run 

ductwork to a roof 

cap or wall cap. 

Tape all ductwork 

connections 

to make them 

secure and air tight.

SPACER

(use for 

mounting 

to I-Joist)

TOP AND BOTTOM FLANGES 

REMAIN OUTSIDE OF HOUSING

I-JOIST

SCREW 

FROM 

PARTS BAG

INSERT

TAB INTO 

SLOT IN 

HOUSING

To ensure a noise-free 

mount: Secure hang-

ing bars together with 

SCREWS and use a 

pliers to crimp mount-

ing channels tightly 

around hanger bars.

Summary of Contents for ULTRA SILENT QTXE150

Page 1: ...all prior warranties and is not transferable from the original consumer purchaser No Other Warranties This Limited Warranty contains the Company s sole obligation and your sole remedy for defective products The foregoing warranties are exclusive and in lieu of any other war ranties express or implied THE COMPANY DISCLAIMS AND EXCLUDES ALL OTHER EXPRESS WARRANTIES ANDDISCLAIMSANDEXCLUDESALLWARRANTI...

Page 2: ...OKING AREA ROOF CAP with built in damper WALL CAP with built in damper 6 IN ROUND ELBOWS 6 IN ROUND DUCT FAN HOUSING Seal gaps around housing Seal duct joints with tape Keep duct runs short INSULATION Place around and over fan housing POWER CABLE Purchase separately OR The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use t...

Page 3: ...ng will be flush with finished surface of ceiling For 1 2 thick ceiling material position bottom of each mounting flange flush with the bottom of joist The housing mounts with four 4 screws or nails Screw or nail housing to joist through low est holes in each mounting flange then through highest holes NOTE Mounting to I JOIST shown requires use of SPACERS included between the highest hole of each ...

Page 4: ...14 Spacer 2 supplied 9 97020013 Hanger Bar Kit 5 Insert mask and finish ceiling Tape mask into housing Mask protects unit dur ing construction Remove before installing grille Install ceiling material Cut out around housing INSTALL MASK FINISH CEILING 4 Connect electrical wiring Run 120 VAC house wiring to installation location Use proper UL approved connector to secure house wiring to wiring plate...

Page 5: ...atural del acabado i Productos en uso comercial o no residencial o j daños ocasionados por incendio inundación u otro caso fortuito Esta garantía cubre solamente Productos vendidos a clientes originales en los Estados Unidos por la Compañía o a distribuidores de EE UU autorizados por la Compañía Esta garantía sustituye todas las garantías anteriores y no es transferible del comprador consumidor or...

Page 6: ...ador integral TAPA DE PARED con amortiguador integral CODO REDONDO DE 6 PULG CONDUCTO REDONDO DE 6 PULG CUBIERTA DE VENTILADOR Selle los huecos alrededor de la cubierta Sellar las juntas con cinta Mantenga corre conducto corto AISLAMIENTO Puede ser colocado alrededor y sobre de la cubierta del ventilador Se compran por separado O CABLE DE ALIMENTACIÓN Los conductos desde este ventilador hacia el e...

Page 7: ...abada del techo Para techos de material de 1 2 de grueso posicione la parte inferior de cada soporte al ras con la parte inferior de cada viga INSTALE LA CUBIERTA Y EL CONDUCTO 2 Acople el conector del regulador de tiro conducto 3 Instale el conducto redondo de 6 pulgadas Conecte el conducto redondo de 6 pulgadas al conector del regulador conducto Extienda el conducto hacia una tapa de techo o tap...

Page 8: ...5 97020011 Conjunto del ventilador 6 97018530 Conjunto de la rejilla incluye la pieza con clave n o 7 7 99140208 Resorte de la rejilla se requieren 2 8 97018014 Separador se suministran 2 9 97020013 Juego de barra de suspensión 4 Conecte los cables eléctricos Extienda el cableado de la casa de 120 V CA al lugar de la in stalación Utilice una conexión aprobada por UL para afianzar el cableado de la...