Before proceeding to the installation, check the contents of the box. If items are missing or
damaged, contact the manufacturer.
Make sure that the following items are included:
TEN2 Series
TEN1 Series
(2) G
REASE
F
ILTERS
(1) 3¼”
X
10”
D
AMPER ASSEMBLY
*
(1) 7” R
OUND
D
UCT
C
ONNECTOR
(1) P
ARTS
B
AG
*** C
ONTAINING
:
(6) N
O
. 8
X
5/8”
RD. HD.
W
OOD
S
CREWS
* F
IND INSIDE
OF HOOD
(2) I
NSTALLATION
B
RACKETS
**
FOR FRAMED CABINET
(2) I
NSTALLATION
B
RACKETS
**
FOR FRAMELESS CABINET
(1) T
EMPLATE FOR DUCTING
(
PRINTED BOTH SIDES
)
(4) N
O
. 8-18
X
1/2”
M
ETAL
S
CREWS
(6) N
O
. 8
X
1/2”
C
OUNTERSUNK
W
OOD
S
CREWS
EZ1 C
OMPONENTS
C
L
A
B
Apoyar este borde contra la pared de atrás
Place this edge against back wall
VERTICAL EXHAUST
S
A
A
V
RTICAL EX
= 3¼” x 10”
= 3¼” x 14”
RECTANGULAR DUCTING
7” ROUND DUCTING
OR
Use this template for marking; do not attempt to cut out the ducting hole through it.
NOTE: These cutouts are clearance holes; they do not need to be the exact size of ducting.
= 3¼ po x 10 po
= 3¼ po x 14 po
CONDUIT RECTANGULAIRE
CONDUIT ROND DE 7 PO
OU
= 3¼ pulg. x 10 pulg.
= 3¼ pulg. x 14 pulg.
CONDUCTO RECTANGULAR
CONDUCTO REDONDO
DE
7 PULG.
O
Appuyer ce bord au mur arrière
Utiliser ce gabarit pour marquer vos repères; ne pas tenter de découper
le trou pour le conduit à travers le gabarit.
NOTE : Les découpes incluent le jeu nécessaire à l’installation; elles ne doivent pas
être du format exact des conduits.
Use esta plantilla para crear marcados; no trate de cortar el
agujero del conducto a través de la plantilla.
NOTA: To be translated in Spanish.
MARK WHERE INDICATED
FOR THE APPROPRIATE SIZE DUCT OPENING
MARQUER LES REPÈRES AUX ENDROITS INDIQUÉS SELON
LE FORMAT DE CONDUIT UTILISÉ
TITLE TO BE TRANSLATED IN SPANISH
Electrical access hole center
A
= single blower hood
B
= double blower hood
Centre du trou pour fil
d’alimentation électrique
A
= hotte ventilateur simple
B
= hotte ventilateur double
To be translated in Spanish
Electrical access hole center
A
= single blower hood
B
= double blower hood
4¼”
10½”
14½”
8”
7½”
C
C
C
Bend template along graduated
scale when installing to framed
cabinet.
Pour une installation sous une
armoire à fond en retrait, utiliser les
lignes pour mesurer l’épaisseur du
décalage causé par le mur de
l’armoire et plier le gabarit en
conséquence.
To be translated in Spanish.
** F
IND
EZ1 B
RACKETS ATTACHED INSIDE OF HOOD
*** F
IND PARTS BAG BEHIND THE DAMPER ASSEMBLY INSIDE OF HOOD
(1) G
REASE
F
ILTER
(1) 3¼”
X
10”
D
AMPER
ASSEMBLY
*
(1) P
ARTS
B
AG
** C
ONTAINING
:
* F
IND
INSIDE
OF
HOOD
(1) 7” R
OUND
D
UCT
C
ONNECTOR
(1) B
ULB
S
UCTION
C
UP
T
OOL
(5) N
O
. 8
X
5/8”
RD. HD.
W
OOD
S
CREWS
** F
IND
PARTS
BAG
BEHIND
THE
DAMPER
ASSEMBLY
INSIDE