INST
ALLA
TION MANUAL
INST
ALLA
TION
15
Install the Hood (EZ1 Bracket) (TEN2 Series only)
1 ]
Run house power cable between service panel and hood location.
2 ]
There are 2 pairs of recessed holes on each side of the top of the hood (on rear:
A
and
B
,
on front
C
and
D
on illustration below); these holes allow the range hood to hang on the
brackets (previously installed).
3 ]
Temporarily hang the hood on the brackets using its 2 recessed REAR HOLES (
A
and
B
).
While holding the hood
, run the house power cable into the hood through the strain relief
previously installed in step
6
on page 10.
4 ]
Unhook the rear holes from the brackets and hang the hood using its 2 recessed FRONT
HOLES (
C
and
D
).
While holding the hood
, attach the power cable to the hood using the
strain relief.
5 ]
Hang the hood on the brackets using the 2 recessed FRONT HOLES (
C
and
D
).
While
holding the hood
, run the house power cable into the hood through the strain relief
previously installed in step
6
on page 10. Attach power cable to the hood.
NOTE: See final installation steps on next page.
HORIZONTAL EXHAUST INSTALLATION ONLY
OTE:
N
The following procedure applies to both framed or frameless cabinet installations.
DUCTED INSTALLATION ONLY
6 ]
Connect the ductwork to the hood and use metal foil duct tape to make joints secure and
air-tight. Make sure the damper assembly (or round duct plate) enters the ductwork and
that the damper opens and closes freely.
A
B
A
B
D
C
VERTICAL EXHAUST INSTALLATION AND NON-DUCTED INSTALLATION ONLY