background image

Page 4

MODELS   QTR080L • QTR110L

SERVICE PARTS

99044601B

Key No.  Part No. 

Description

 

97016466 

Housing

 

97016449 

Duct Connector-4”

 

98010102 

Wiring Plate

 

99170245 

Screw, #8-18 X .375

 

97018011 

Wire Panel/Harness Assembly

 

97017850 

Blower Assembly (QTR080L)

 

 

97018218 

Blower Assembly (QTR110L)

 

97016546 

Grille Assembly

 

 

 

  (includes key nos. 8 & 9)

 

99140199 

Grille Spring (2 req’d)

 

99111281 

Lens

 

10 

97018014 

Spacer (2 supplied)

 

11 

99420665 

Thumbscrew, #8-18 x .375

SERVICE NOTE

To remove Blower 
Assembly:
Unplug motor.
Remove thumbscrew 
(11)  from motor plate 
flange.
Find the single 

TAB

 

on the motor plate 
(located next to the 
receptacle).
Push up near motor 
plate tab while pushing 
out on side of housing. 
Or insert a straight-
blade screwdriver 
into slot in housing 
(next to tab) and twist 
screwdriver.

Order service parts by “Part No.” - not by “Key No.”

9.  Remove 

light lens.

 

Carefully insert a 
small flat-blade 
screwdriver be-
tween grille and 
lens. Pry lens 
out.

8.  Push grille 

against 
ceiling.

10. Install light bulbs.

Purchase an incandes-

cent bulb - 100W Max.

 

Purchase a 4W incan-

descent night light bulb.

 

Insert bulbs into their 

sockets. Replace lens.

Replacement parts 

can be ordered on our 

website. Please visit us 

at www.broan.com

Summary of Contents for QTR080L

Page 1: ...the motor bearings are making excessive or unusual noises replace the blower assembly includes motor and impeller OPERATION The fan light and night light can be operated separately Use a 3 function w...

Page 2: ...45o NOT FOR USE IN A COOKING AREA The unit will operate most quietly and efficiently when located where the shortest possible duct run and minimum number of elbows will be needed Use a roof cap or wal...

Page 3: ...ions to make them secure and air tight INSTALL HOUSING DUCT 1 Bend housing tabs Use a pliers to bend housing TABS out to 900 2 Mount housing to joist Hold housing in place so that the housing tabs con...

Page 4: ...otor Remove thumbscrew 11 from motor plate flange Find the single TAB on the motor plate located next to the receptacle Push up near motor plate tab while pushing out on side of housing Or insert a st...

Page 5: ...i n Conexi n el ctrica Para registrar este producto visite www broan com LIMPIEZA Y MANTENIMIENTO Para lograr un funcionamiento silencioso y eficiente como tambi n larga vida y una apariencia atractiv...

Page 6: ...COCINA El ventilador funcionar con m s eficiencia y menos ruido si se ubica en un sitio donde requiera el tramo de conducto m s corto posible y un m nimo n mero de codos Instale una tapa de techo o d...

Page 7: ...xiones de los conductos para fijarlas y hacerlas herm ticas al aire 3 Acople el conectador del regulador de tiro conducto Conecte a presi n el conectador del regu lador de tiro conduc to en la cubiert...

Page 8: ...servicio se debe especificar el n mero de la pieza no el n mero de la clave 8 Empuje la rejilla contra el cielo raso 10 Instale las bombillas Compre una bombilla incan descente m x 100 W Compre una bo...