background image

4

WIRING DIAGRAMS

1101653A

Tape mask into housing. 

Mask protects unit during 

construction. Remove 

before attaching grille.
Install ceiling material. Cut 

out around housing.

Install housing mask.

1

7

Attach grille.

1

8

If grille spring becomes 

dislodged from grille - snap it 

back into place as shown.

Connect wiring.

1

6

Screw from 

Parts Bag

Attach cable clamp to 

Knockout Plate. Knockout 

Plate mounts to outside of 

Housing and may be oriented 

as desired.

Connect wires

3

4

1

2

Connect power cable to wiring 

plate (from parts bag) using UL 

approved connector. Connect 

house wiring to fan wiring. Refer 

to wiring diagrams for connection 

details. Use screw (from parts 

bag) to secure wiring plate to fan 

housing. Re-install wiring panel 

and secure with screw from parts bag.

3

4

1

2

1

3

2

1

3

2

ON / OFF SWITCH

(PURCHASE SEPARATELY)

ON / OFF

SWITCH

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

BLK

WHT

UNIT

ORG

BLK

WHT

GRD

WHT

BLK

WHT

BRN

HUMIDITY
CONTROL

FAN

RED

RED

120

VAC

LINE

IN

SWITCH BOX

WHT

GRD

WHT

UNIT

BLK

WHT

GRD

WHT

BLK

WHT

HUMIDITY
CONTROL

FAN

RED

BLK

ORG

BRN

2-FUNCTION CONTROL

(PURCHASE SEPARATELY)

COM

(1)

HUMIDITY
CONTROL

(AUTO/OFF)

(2)

FAN

(ON/OFF)

WIRING OPTION #1

•  When switch is ON, fan will operate automatically, 

based on room humidity conditions.

•  Turn fan ON immediately for the set timer period (to 

control odors), by cycling switch.

WIRING OPTION #2

•  When first switch (1) is ON, fan will operate automatically based on 

room humidity conditions.

•  Turn fan ON 

immediately 

(to control 

odors) by 

using sec-

ond switch 

(2).

Plug in sensor

Summary of Contents for QT DC 110 CFM

Page 1: ...sensor is mounted in the control housing The sensor will operate most reliably when cleaned occasionally as follows 1 Disconnect power at service entrance 2 Remove the grille Use a dry dustcloth clean...

Page 2: ...ot install above or inside this area 45o 45o NOT FOR USE IN A COOKING AREA Housing mounted to I joists Use I joist spacer block provided Housing mounted anywhere between I joists using hanger bars Hou...

Page 3: ...secure blower to housing Screws from parts bag 1 3a Mount housing to joist SPACER use for mounting to I Joist I JOIST Hold housing in place so that bottom edge of housing will be flush with finished s...

Page 4: ...rts bag to secure wiring plate to fan housing Re install wiring panel and secure with screw from parts bag 3 4 1 2 1 3 2 1 3 2 ON OFF SWITCH PURCHASE SEPARATELY ON OFF SWITCH 120 VAC LINE IN SWITCH BO...

Page 5: ...e suit de temps autre 1 Coupez le courant au panneau lectrique 2 Enlevez la grille l aide d un chiffon pousseter d une brosse dents propre ou d un aspirateur nettoyez d licatement le d tecteur et la g...

Page 6: ...H0033F GRILLE BO TIER MAT RIAU DE PLAFOND C BLE LECTRIQUE BRIDES DE MONTAGE FERME IMPORTANT Les conduits allant de ce ventilateur jusqu l ext rieur de l habitation ont une grande influence sur le d bi...

Page 7: ...EXT RIEUR DU BO TIER INS RER LA PATTE DANS LA FENTE DU BO TIER VIS PROVENANT DU SAC DE PI CES Certains mod les uniquement S lectionnez 110 130 ou 150 CFM en fonction des dimensions de la pi ce et du...

Page 8: ...t rieur du bo tier d un c t comme de l autre 3 4 1 2 1 3 2 1 3 2 RGE INTERRUPTEUR MARCHE ARR T VENDU S PAR MENT INTERRUPTEUR MARCHE ARR T ENTR E 120 Vca BLANC FIL DE TERRE NOIR BLANC APPAREIL ORG NOIR...

Page 9: ...ehumedadest montadoenlacubiertadecontrol Elfuncionamiento del sensor ser m s confiable si se limpia ocasionalmente Para ello haga lo siguiente 1 Desconecte la energ a en la entrada de servicio 2 Quite...

Page 10: ...onductosm scortoyrectoposibleparaobtener undesempe o ptimoyeviteinstalarelventiladorconconductosmenoresque losrecomendados Elaislamientoalrededordelosconductospuedereducirla p rdida de energ a e inhib...

Page 11: ...de tiro conducto Instale el conducto redondo de 6 pulgadas 1 4 1 5 Conecte el conducto redondo de 6 pulgadas al conector del regulador conducto Extienda el conducto hacia una tapa de techo o tapa de p...

Page 12: ...e ubicar en la direcci n deseada Conecte los cables 3 4 1 2 1 3 2 1 3 2 ROJ L NEA DE ENTRADA DE 120 VCA CAJA DEL INTERRUPTOR BLANCO TIERRA BLANCO UNIDAD NEGRO BLANCO TIERRA BLANCO NEGRO BLANCO CONTROL...