Please take note that this manual uses the following symbols to emphasize particular information:

WARNING

Identifies an instruction which, if not followed, might cause serious personal injuries 

including possibility of death.

CAUTION

Denotes an instruction which, if not followed, may severely damage the unit and/or its 

components.

💡

 

Indicates a supplementary information that may relate to optional parts or simply aim to 

facilitate a task.

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSON(S) OBSERVE THE 
FOLLOWING:

1.  Use this unit only in the manner intended by the manufacturer. If you have questions, contact the 

manufacturer.

2.  Before servicing or cleaning this unit, disconnect the power cord from the electrical outlet. 

3.  This unit is not designed to provide combustion and/or dilution air for fuel-burning appliances.

4.  Do not use this unit with any solid-state speed control device.

5.  Do not operate any fan with a damaged cord or plug. Discard fan or contact your HVAC contractor, or 

the manufacturer.

6.  Do not run cord under carpeting. Do not cover cord with throw rugs, runners or similar coverings. Do 

not route cord under furniture or appliances. Arrange cord away from traffic area and where it will not 

be tripped over.

7.  Installation work must be done by qualified person(s) in accordance with all applicable codes and 

standards, including fire-rated construction.

8.  When cutting or drilling into a wall or ceiling, do not damage electrical wiring and other hidden utilities.

9.  This unit must be grounded. The power supply cord has a 3-prong grounding plug for your personal 

safety. It must be plugged into a mating 3-prong grounding receptacle, grounded in accordance with 

the national electrical code and local codes and ordinances. Do not remove the ground prong. Do not 

use an extension cord.

10. When servicing, cleaning or performing installation of this unit, it is recommended to wear safety 

glasses and gloves.

11. When applicable local regulation comprises more restrictive installation and/or certification requirements, 

the aforementioned requirements prevail on those of this document and the installer agrees to conform 

to these at his own expenses.

12. The unit must be mounted at least 3.3 feet (1.0 meter) away from any accessible opening of the duct.

CAUTION

1.  Please read specification label on product for further information and requirements.

2.  Do not intake air into spaces within walls or ceiling or into attics, crawl spaces, or garage. Do not 

attempt to recover the exhaust air from a dryer or a range hood.

3.  Intended for residential installation only in accordance with the requirements of NFPA 90B.

4.  When leaving the house for a long period of time (more than two weeks), a responsible person should 

regularly check if the unit operates adequately.

5.  At least once a year, the unit mechanical and electronic parts should be inspected by qualified service 

personnel.

6.  Since the electronic control system of the unit uses a microprocessor, it may not operate correctly 

because of external noise or very short power failure. If this happens, unplug the unit and wait 

approximately 10 seconds. Then, plug the unit in again.

7.  Outdoor intake hood must be weather tight and comprise a bird screen.

8.  Should you decide to dispose of this unit or of parts of it, do so in accordance with local laws and 

regulation.

9.  Some areas are prone to a higher frequency of lightning-induced power surges. Using a surge protector 

device to protect units located in these areas is recommended.

Summary of Contents for FRESH IN FIN-180B

Page 1: ...VB0258 FRESH INTM BASIC FIN 180B INSTALLATION INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS RESIDENTIAL USE ONLY REGISTER YOUR PRODUCT ONLINE AT www broan com register...

Page 2: ...nding receptacle grounded in accordance with the national electrical code and local codes and ordinances Do not remove the ground prong Do not use an extension cord 10 When servicing cleaning or perfo...

Page 3: ...especially if you live near a highway or in an area where there is a lot of construction work generating lots of dust Your filter s may need more frequent cleaning or replacement in these types of en...

Page 4: ...y fan is 12 inches The temperature distributed in the dwelling should not be below 55 F 2 2 2 INSTALLATION WITH AN AHU The installer shall ensure that if necessary an in line heater sized according to...

Page 5: ...ow Range to High range and to adjust the CFM value An optional MERV filter may be installed now The main filter should remain as a prefilter and the MERV filter should be installed as indicated above...

Page 6: ...all or ceiling into the studs joists or other solid material When wall mounted the unit can be positioned in any orientation to suit your need 3 1 2 CEILING HUNG The brackets have been designed to all...

Page 7: ...e installed before installing the brackets 1 Using 4 screws no 8 18 x 0 375 in install the brackets on the unit following the diagram below to adapt to the thickness of the ceiling 2 Using 4 screws no...

Page 8: ...ce garbage bin and any other source of contamination Make sure that the outdoor intake hood is easily accessible for annual maintenance If located above the first floor place it close to a window or b...

Page 9: ...accidentally LOGIC DIAGRAM WIRING COLOR CODE BLK BLACK BLU BLUE GRN GREEN ORG ORANGE RED RED WHT WHITE Line voltage factory wiring Low voltage factory wiring Low voltage eld wiring BLK Supply fan moto...

Page 10: ...your ventilation unit remains in good working condition you must use Broan NuTone LLC genuine replacement parts only The Broan NuTone LLC genuine replacement parts are specially designed for each uni...

Page 11: ...the measuring tool accurate Try using a different tool Calibratetool Damper does not close Iftheductwork of the supply fan is connected to the ductwork of an AHU turn OFF the AHU temporarily Is the d...

Page 12: ...oval reinstallation and shipping insurance or other freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by...

Page 13: ...VB0258 FRESH INTM BASIC FIN 180B INSTRUCCIONES DE INSTALACI N LEA Y GUARDE ESTAS INSTRUCCIONES PARA USO RESIDENCIAL NICAMENTE REGISTRE SU PRODUCTO EN L NEA EN www broan com register...

Page 14: ...s conectada a tierra de acuerdo con el c digo el ctrico nacional y los c digos y ordenanzas locales No retire la patilla de la toma de tierra No utilice el aparato con un cable prolongador 10 Durante...

Page 15: ...ta o en una zona donde hay muchas obras de construcci n que generan mucho polvo En tales condiciones puede que sea necesario limpiar o cambiar los filtros con mayor frecuencia Sustituya los filtros op...

Page 16: ...los conductos no debe ser inferior a 55 F 2 2 2 INSTALACI N CON UNA AHU El instalador deber asegurarse de que de ser necesario se instale un calentador en l nea de un tama o acorde con la corriente de...

Page 17: ...pi3 min Utilice un destornillador peque o de punta plana para pasar de la gama baja a la gama alta y para ajustar el valor pi3 min Ahora se puede instalar un filtro MERV opcional El filtro principal d...

Page 18: ...x 0 625 pulg u otros tornillos m s largos si es necesario Cuando se instale en una pared el aparato puede orientarse como se desee en funci n de sus necesidades 3 1 2 COLGADO DEL TECHO Los soportes ha...

Page 19: ...larse antes que los soportes 1 Instale los soportes en el aparato siguiendo el diagrama de abajo para adaptarse al grosor del techo utilice para ello 4 tornillos no 8 18 x 0 375 pulg 2 Instale el apar...

Page 20: ...ente de contaminaci n Aseg rese de que se pueda acceder f cilmente a la boca de admisi n de aire exterior para el mantenimiento anual Si se encuentra por encima de la primera planta col quela cerca de...

Page 21: ...A L GICO C D DE COLORES CABLEADO NE NEGRO AZ AZUL VE VERDE NA NARANJA RO ROJO BL BLANCO Cableado de f brica de tensi n de l nea Cableado de f brica de baja tensi n Cableado in situ de baja tensi n NE...

Page 22: ...l aparato de ventilaci n est en buenas condiciones s lo debe utilizar repuestos Broan NuTone LLC genuinos Los repuestos Broan NuTone LLC genuinos han sido dise ados especialmente para cada aparato han...

Page 23: ...enta de medici n Intente utilizar una herramienta diferente Calibre la herramienta La compuerta no cierra Si los conductos delventilador de alimentaci n est n conectados a los conductos de una unidad...

Page 24: ...s responsable de todos los costos de extracci n reinstalaci n transporte seguros u otros cargos de flete por el env o del Producto o de la pieza a la Empresa Si debe enviar el Producto o la pieza a la...

Reviews: