3. PREPARATION
1. Remove the unit from the box and inspect for damage. Installation hardware is located in a plastic bag
along with this guide, on top of the filler.
2. Put the unit down on a protected surface.
3. Refer to your local building code to determine the required airflow.
4. Open the unit’s door to access the settings on the electrical compartment cover.
5. Adjust the settings according to the required airflow. The first number around the Airflow Range
adjustment is the Low Range CFM value (30-100 CFM), and the second number is the High Range
CFM value (110-180 CFM). Use a small flat blade screwdriver to switch from Low Range to High
range, and to adjust the CFM value.
💡
An
optional MERV filter may be installed now. The main filter should remain as a prefilter, and the
MERV filter should be installed as indicated above.
3.1 M
OUNTING
THE
U
NIT
💡
When choosing a location for this unit, keep in mind that maintenance will have to be performed by
the end user on a regular basis. Choose an easily accessible location and plan for a 14-in. clearance
for the door to open.
VD0463
AIRFLOW ADJUSTMENT
Low
range
High
range
Refer to the manual for more details.
www.broan.com
50/130
60/140
70/150
80/160
90/170
100/180
40/120
30/110
Low /
High range
AIRFLOW DIRECTION
MERV Filter Main Filter
With optional
decorative trim
FLUSH TO CEILING
VD0467
12"
ATTIC MOUNTED
VD0466
12"
VH0152
10"
10"
WALL MOUNTED
UNDER CEILING
10¼"
VH0154
10"
CEILING HUNG
VH0153A
14¼" clearance