MODELS  QP130BL • QP130BLC • QP130SS • QP130SSC

QP130WW • QP130WWC • QP136BL • QP136SS • QP136WW

Page 3

3¼” X 10” 

HORIZONTAL DUCTING

CABINET

BOTTOM

CABINET FRONT

HORIZONTAL DUCT

ACCESS HOLE

5¼"

5¼"

HOOD

MOUNTING

SCREWS (5)

ELECTRICAL

ACCESS HOLE

(in wall)

4"

CENTER

LINE

WOOD SHIMS

(recessed-bottom

cabinets only)

14

5

/

8

(36" hood)

11

5

/

8

(30" hood)

14

5

/

8

(36" hood)

11

5

/

8

(30" hood)

8½"

1½"

3

/

8

"

4

7/8

*

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

14

5

/

8

(36" hood)

2

3

/

8

"

14

5

/

8

(36" hood)

11

5

/

8

(30" hood)

11

5

/

8

(30" hood)

8½"

10

7

/

8

"

2

5

/

8

"

HOOD MOUNTING SCREWS (5)

4

5

/

8

"

7-IN. ROUND

DUCT

ACCESS

HOLE

7-IN. ROUND

DUCT

ACCESS

HOLE

8" DIA.

HOLE

4

7/8

*

7-IN. ROUND 

DUCTING

PREPARE THE HOOD

ALUMINUM

FILTERS

Remove the 

Aluminum Filters

 from the hood.

(2)

LIFT

OUT

(1)

PULL

DOWN

Remove all protective polyfilm from the hood (stainless 

steel hoods only).

Remove parts bag from inside the foam packaging end 

cap.

è

è

VERTICAL DUCT

ACCESS HOLE

¾"

10

7/8

"

5¼"

5¼"

CENTER

LINE

HOOD MOUNTING SCREWS (5)

ELECTRICAL

ACCESS HOLE

(in cabinet bottom)

WOOD SHIMS

(recessed-bottom

cabinets only)

CABINET FRONT

CABINET
BOTTOM

14

5/8

(36" hood)

4½"

2

3/8

"

14

5/8

(36" hood)

11

5/8

(30" hood)

11

5/8

(30" hood)

2

5/8

"

4

7/8

*

8

1/2

"

3¼” X 10” 

VERTICAL DUCTING

Use the proper diagram below, for placement of 

ductwork and electrical cutout in cabinet or wall. For a 

non-ducted installation, DO NOT cut a duct access hole.

*

  Note the extra wood shim and mounting screw near    

  the cabinet front, 4-7/8” to the right of the cabinet 

  center line.

Remove 2 screws holding 

Damper / Duct Connector

 to 

hood. Remove damper/duct connector from inside the 

hood.

FOR DUCTED INSTALLATIONS - Skip to Step 9.

DAMPER /

DUCT CONNECTOR

Summary of Contents for EVOLUTION 1 QP130BL

Page 1: ...Peppercorn Beef Flamb 3 Clean ventilating fans frequently Grease should not be al lowed to accumulate on fan or filter 4 Use proper pan size Always use cookware appropriate for the size of the surfac...

Page 2: ...dishwasher using a non phosphate detergent Discoloration of the filter may occur if using phosphate detergents or as a result of local water conditions but this will not affect filter performance Thi...

Page 3: ...OUT 1 PULL DOWN 4 Remove all protective polyfilm from the hood stainless steel hoods only 3 Remove parts bag from inside the foam packaging end cap VERTICAL DUCT ACCESS HOLE 107 8 5 5 CENTER LINE HOO...

Page 4: ...x 10 Damper Duct Connector with the Damper Flap Pivot nearest the Top Back Edge of Hood TOP BACK EDGE OF HOOD 7 NON DUCTED INSTALLATION ONLY Remove Center Retaining Screw and loosen Outer Retaining Sc...

Page 5: ...INSTALL LIGHT BULBS 16 Install 4 Halogen Bulbs Use 120 V 35 W shielded halogen bulbs MR16 with GU10 base Purchase bulbs separately NOTE Suction Cup Tool included with hood can be used to install and r...

Page 6: ...m defects in materials or workmanship for a period of one 1 year from the date of original purchase THERE ARE NO OTHER WARRANTIES EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF...

Page 7: ...cr pes Suzette cerises jubil steak au poivre flamb 3 Nettoyez souvent la hotte Ne laissez pas la graisse s accumuler sur le ven tilateur ou le filtre 4 Utilisez des casseroles de dimension appropri e...

Page 8: ...3 x 25 4 cm 3 1 4 x 10 po ou conduit rond de 17 8 cm 7 po ou l horizontale 8 3 x 25 4 cm 3 1 4 x 10 po seulement Pour une vacuation verticale ou horizontale installez les conduits entre un capuchon d...

Page 9: ...lapet raccord de con duit sur la hotte Retirez le clapet raccord de conduit de l int rieur de la hotte INSTALLATIONS AVEC CONDUITS Passez l tape 9 CLAPET RACCORD DE CONDUIT FILTRES D ALUMINIUM 5 Retir...

Page 10: ...t vertical de 8 3 x 25 4 cm 3 x 10 po OUVERTURE PR AMORC E POUR CONDUIT VERTICAL DE 8 3 x 25 4 cm 3 x 10 po OUVERTURE PR AMORC E POUR CONDUIT HORIZONTAL DE 8 3 x 25 4 cm 3 x 10 po CLAPET RACCORD DE CO...

Page 11: ...ez 4 ampoules halog nes Utilisez des ampoules halog nes avec cran de 120 V 35 W MR16 culot GU10 Veuillez vous procurer les ampoules s par ment REMARQUE Vous pouvez utiliser la ventouse incluse avec la...

Page 12: ...un an Broan NuTone garantit au consommateur et acheteur initial de ses produits que ceux ci sont exempts de tout vice de mat riau ou de fabrication pour une p riode d un 1 an compter de la date d ach...

Page 13: ...s por ejemplo crepas Suzette cerezas Jubilee bistec con pimienta flameado 3 Limpie frecuentemente los ventiladores No permita la acumulaci n de grasa en el ventilador ni en el filtro 4 Use una cacerol...

Page 14: ...MA DE LA SUPERFICIE DE COCINADO GABINETE CONDUCTO DE 3 x 10 pulg 8 3 x 25 4 cm para descarga horizontal TAPA DE PARED TAPA DE TECHO CONDUCTO DE 3 x 10 pulg 8 3 x 25 4 cm o CONDUCTO REDONDO de 7 pulg 1...

Page 15: ...ujetan el conector del regulador de tiro conducto a la campana Saque el conector del regulador de tiro conducto del interior de la campana PARA INSTALACIONES CON CONDUCTOS pasar directamente al paso 9...

Page 16: ...campana hacia cualquier lado Recorte la brida del conector de conductos o la placa de conductos si se cruza con la abrazadera del cable el ctrico INSTALE LA CAMPANA ADVERTENCIA Para reducir el riesgo...

Page 17: ...e bombillas de hal geno con escudo protector de 120 V 35 W MR16 con base GU10 Las bombillas se compran por separado NOTA La herramienta de ventosa incluida con la campana sirve para instalar y quitar...

Page 18: ...A Garant a limitada por un a o Broan NuTone garantiza al consumidor comprador original de sus productos que tales productos estar n libres de defectos en materiales o mano de obra durante un per odo d...

Page 19: ......

Page 20: ...99526629K...

Reviews: