Broan Elite EW4824SS Installation Use And Care Manual Download Page 3

3

1. P

REPARE

 

INSTALLATION

. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

2. S

ELECT

 

INSTALLATION

 

TYPE

. . . . . . . . . . . . . . . . . . . . . . . . . 3 

3. B

UILD

 

FRAMEWORK

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

4. I

NSTALL

 

UPPER

 

FLUE

 

MOUNTING

 

BRACKET

 (

DUCTED

 

INSTALLATION

 

ONLY

)   4

5. I

NSTALL

 

PLENUM

 (

NON

-

DUCTED

 

INSTALLATION

 

ONLY

) . . . . . . . . . 4

6. R

EMOVE

 

GREASE

 

FILTER

(

S

) . . . . . . . . . . . . . . . . . . . . . . . . . 5

7. I

NSTALL

 

THE

 

HOOD

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5

8. C

ONNECT

 

WIRING

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

9. D

UCT

 

CONNECTION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7

10. P

REPARE

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . . . 8

11. I

NSTALL

 

THE

 

DECORATIVE

 

FLUE

. . . . . . . . . . . . . . . . . . . . .  8-9

12. R

EINSTALL

 

GREASE

 

FILTER

(

S

)  . . . . . . . . . . . . . . . . . . . . . . . 9

13. O

PERATION

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

14. C

ARE

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

15. R

EPLACEMENT

 

PARTS

. . . . . . . . . . . . . . . . . . . . . . . . . . . .  11

16. W

ARRANTY

  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

TABLE OF CONTENTS

1. PREPARE INSTALLATION

NOTE: Before proceeding to the installation, check the contents of the box. If items are missing or damaged, contact the retailer.
Make sure that the following items are included:

- Hood
-  Decorative flue assembly (lower and upper flues)
-  Upper flue mounting bracket
- Aluminum grease filter(s) (1 for 24-in. width hood, 2 for 30-in. and 
 

36-in. width hoods)

- Installation 

instructions

-  Parts bag:  6 M4 x 38 Phillips 9 mm round head mounting screws,

2

 

M4 x 12 Phillips 9 mm

 

round head screws, 

2 washers and 3

 

wire connectors

Parts sold separately:

-  Ducts, elbows, wall and roof caps.
-  Optional flue extension for

 

ceilings of 9 ft. or more: models AEEW48SS 

(stainless steel), AEEW48BLS (black stainless steel) or AEEW48WH (white).

-  Non-duct kit model ARKEW48, mandatory for non-ducted installation.
NOTE: During installation, protect countertop and/or cooktop.

2.  SELECT INSTALLATION TYPE

2.1 N

ON

-D

UCTED

 I

NSTALLATION

 

The ARKEW48 non-duct kit is required for a non-ducted installation.

2.2 D

UCTED

 I

NSTALLATION

 

Plan where and how the ductwork will be installed.
A straight, short duct run will allow the hood to perform most efficiently. Long duct 
runs, elbows and transitions will reduce the performance of the hood. Use as few 
of them as possible. Larger ducting may be required for longer duct runs.
Install wall or roof cap. Connect 6” round metal ductwork to cap and work back 
towards the hood location. Use 2” metal foil duct tape to seal the joints.

2.3 A

LL

 I

NSTALLATIONS

 

The minimum hood distance above cooktop is 24”. A maximum of 30” above 

 

cooktop is recommended for best capture of cooking impurities.

 

Distances over 30” are at the installer and users discretion providing that ceiling 

 

height and decorative flue length allow it.

 

NOTE:  Ceilings of 9 ft. or more require flue extension model AEEW48SS (stainless

 

 

steel), AEEW48BLS (black stainless steel) or AEEW48WH (white).

6” R

OUND

DUCT

R

OOF

 

CAP

6” R

OUND

ELBOW

W

ALL

 

CAP

H

OOD

D

ECORATIVE

FLUE

HH0281A

24” 

MINIMUM

 

ABOVE

COOKING

 

SURFACE

    WARNING

!

When performing installation, servicing or cleaning the unit, it is recommended to wear safety glasses and gloves.

HR0224A

(1) D

ECORATIVE

 

FLUE

     

ASSEMBLY

(1) U

PPER

 

FLUE

MOUNTING

 

BRACKET

(1 

OR

 2) G

REASE

 

FILTER

(

S

)

(6) M4 

X

 38 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

 

(2) M4 

X

 12 P

HILLIPS

 

ROUND

 

HEAD

 

SCREWS

(2) W

ASHERS

(3) W

IRE

 

CONNECTORS

Summary of Contents for Elite EW4824SS

Page 1: ...Serial number 99046144B WWW BROAN COM WWW BROAN CA WW WW BR CHIMNEY RANGE HOOD EW48 Series INSTALLATION USE AND CARE MANUAL...

Page 2: ...ly 2 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors 3 To avoid motor bearing damage and noisy and or unbalanced impeller keep drywall spray construc...

Page 3: ...llation protect countertop and or cooktop 2 SELECT INSTALLATION TYPE 2 1 NON DUCTED INSTALLATION The ARKEW48 non duct kit is required for a non ducted installation 2 2 DUCTED INSTALLATION Plan where a...

Page 4: ...lips 9 mm round head mounting screws in wall framing do not completely tighten the screws at this time 4 INSTALL UPPER FLUE MOUNTING BRACKET DUCTED INSTALLATION ONLY Center the upper flue mounting bra...

Page 5: ...2 M4 x 38 Phillips 9 mm round head mounting screws and 2 washers in the lower back of the hood see back view at right Tighten both screws completely WARNING BE CAREFUL when installing the decorative...

Page 6: ...ockout from the junction box cover top HR0226 Install a UL approved strain relief not included on the house power cable at 4 from the cable end Run the power cable in the junction box cover opening th...

Page 7: ...d metal ductwork to wall cap and 90 elbow over duct collar then install the 90 elbow over the adapter damper on the hood Use metal foil duct tape to seal the joints NON DUCTED INSTALLATION Remove the...

Page 8: ...on installation heights NOTE Both lower and upper flues are included with the hood but for ceilings of 9 ft or more discard the provided lower and upper flues and use the optional flue extension part...

Page 9: ...plenum Secure the upper flue to the plenum using 2 M4 x 12 Phillips 9 mm round head screws Remove protective plastic film covering the upper flue and the hood 11 INSTALL THE DECORATIVE FLUE CONTINUED...

Page 10: ...hwasher using a non phosphate detergent Discoloration of the filters may occur if using phosphate detergents or as a result of local water conditions but this will not affect filter performance This d...

Page 11: ...H BRACKET 1 1 1 S97021439 DECORATIVE UPPER AND LOWER FLUES WHITE 1 S97021440 DECORATIVE UPPER AND LOWER FLUES BLACK STAINLESS STEEL 1 1 2 S97021442 DAMPER ASSEMBLY 1 1 1 3 S99010479 LED MODULE 1 1 1 4...

Page 12: ...freight charges incurred in the shipment of the Product or part to the Company If you must send the Product or part to the Company as instructed by the Company you must properly pack the Product or p...

Page 13: ...Num ro de s rie 99046144B WWW BROAN COM WWW BROAN CA WW WW BR B HOTTE CHEMIN E S rie EW48 MANUEL D INSTALLATION D UTILISATION ET D ENTRETIEN...

Page 14: ...es Suzette cerises jubil steaks au poivre flamb s c Nettoyezr guli rementlaroueduventilateur Nelaissezpaslagraisse s accumuler sur le ventilateur les filtres ou les conduits d vacuation d Utilisezlebo...

Page 15: ...R LE TYPE D INSTALLATION 2 1 INSTALLATION EN RECIRCULATION L ensemble de recirculation ARKEW48 est requis pour ce type d installation 2 2 INSTALLATION AVEC CONDUITS D terminer quel endroit et de quell...

Page 16: ...2 vis de montage M4 x 38 Phillips t te ronde 9 mm dans le cadre du mur ne pas serrer compl tement les vis 3 CONSTRUIRE LA CHARPENTE 34 PO BAS DE LA HOTTE 24 PO AU DESSUS DU PLAN DE CUISSON 40 PO BAS...

Page 17: ...entre de l installation Abaisser doucement la hotte jusqu ce qu elle s accroche aux vis dans le mur 2 Mettre la hotte de niveau et serrer compl tement les vis dans le mur 3 Fixer au mur la hotte en in...

Page 18: ...non fourni sur le c ble d alimentation r sidentiel 4 po du bout du c ble Passer le c ble d alimentation dans l ouverture du couvercle de la bo te de jonction et utiliser le serre c ble pour fixer le c...

Page 19: ...u capuchon mural et un coude de 90 sur l adaptateur volet de la hotte Sceller herm tiquement les joints l aide de ruban adh sif de m tal INSTALLATION EN RECIRCULATION Enlever les volets de l adaptateu...

Page 20: ...ions selon les hauteurs d installation Retirer le conduit d coratif sup rieur de l int rieur du conduit d coratif inf rieur Retirer la pellicule de plastique protectrice recouvrant le conduit d corati...

Page 21: ...ntr dans l illustration afin de faciliter la compr hension Enlever le plastique protecteur couvrant le conduit d coratif sup rieur et la hotte HO0292 VUE AVANT DU SUPPORT DE MONTAGE DU CONDUIT D CORAT...

Page 22: ...cer avec de l eau claire 2 3 fois et essuyer compl tement Un nettoyant domestique con u sp cialement pour l acier inoxydable peut aussi tre utilis ne pas faire Ne pas utiliser de laine d acier ou d ac...

Page 23: ...INOXYDABLE AVEC SUPPORT 1 1 1 S97021439 CONDUIT D CORATIF SUP RIEUR ET INF RIEUR BLANC 1 S97021440 CONDUIT D CORATIF SUP RIEUR ET INF RIEUR ACIER INOXYDABLE NOIR 1 1 2 S97021442 ENSEMBLE DU VOLET 1 1...

Page 24: ...a pi ce la Soci t tel que la Soci t vous l indiquera vous devrez l emballer correctement La Soci t n est pas responsable des dommages subis lors du transport La Soci t se r serve le droit d utiliser d...

Page 25: ...1 N mero de serie 99046144B WWW BROAN COM WWW BROAN CA WW WW BR CAMPANA DE ESTUFA DE CHIMENEA Serie EW48 MANUAL DE INSTALACI N UTILIZACI N Y CUIDADO...

Page 26: ...pimienta flambeada c Limpieelventiladorconfrecuencia Nodejequelagrasaseacumule en el ventilador ni en los filtros o en los conductos de evacuaci n d Utilice cacerolas de tama o apropiado Emplee siempr...

Page 27: ...I N 2 1 INSTALACI N SIN CONDUCTO El conjunto para instalaci n sin conducto modelo ARKEW48 es necesario para este tipo de instalaci n 2 2 INSTALACI N CON CONDUCTOS Planifique d nde y c mo instalar los...

Page 28: ...sor y 3 pulg de altura Sujete la estructura mural de madera a los montantes para lograr una instalaci n s lida Aseg rese de que la altura de la estructura permitir sujetar los tornillos conforme a las...

Page 29: ...aci n previamente trazada en la pared Baje lentamente la campana hasta que encaje en los tornillos de la pared 2 Ponga a nivel la campana y apriete totalmente los tornillos 3 Sujete la campana a la pa...

Page 30: ...obada por UL no provista sobre el cable de alimentaci n de la casa a 4 pulg del extremo del cable Pase el cable de alimentaci n a trav s de la abertura de la tapa de la caja de conexiones y utilice la...

Page 31: ...a tapa para pared y el codo de 90 sobre el adaptador compuerta en la campana Utilice cinta adhesiva met lica para sellar las juntas INSTALACI N SIN CONDUCTO Retirar las compuertas del adaptador Mida l...

Page 32: ...cultar las rejillas en algunas aplicaciones dependiendo de las alturas de instalaci n Retire la parte superior del interior de la parte inferior de la chimenea decorativa Retire la pel cula protectora...

Page 33: ...ci n para facilitar la comprensi n Retire la pel cula protectora de pl stico que cubre la parte superior de la chimenea y la campana HO0292 VISTA FRONTAL DEL SOPORTE DE MONTAJE DE LA PARTE SUPERIOR DE...

Page 34: ...s en el lavaplatos con un detergente sin fosfato Los filtros de pueden descolorar si se lavan con detergentes con fosfato o debido a las caracter sticas del agua local pero esto no afecta su desempe o...

Page 35: ...SUPERIOR Y INFERIOR ACERO INOXIDABLE NEGRO 1 1 2 S97021442 CONJUNTO DE LA COMPUERTA 1 1 1 3 S99010479 M DULO LED 1 1 1 4 S97021444 CONJUNTO DE MOTOR Y VENTILADOR 1 1 1 5 S97021443 TARJETA ELECTR NICA...

Page 36: ...iar el Producto o la pieza a la Compa a tal como lo indique la Compa a debe empaquetar adecuadamente el Producto o la pieza la Compa a no se hace responsable por los da os en tr nsito La Compa a se re...

Reviews: