28
Section D – Electrical Components
Key Switch
REMOvE AND REPLACE
Part mechanical, part electrical, the key switch gives the
operator three options: ON, OFF and LOCK.
SCREWS
CONTROL
PANEL
INTERLOCK
SWITCH
KEY SWITCH
ASSEMBLY
DISPLAY
MODULE
KEY
Remove the control panel assembly (see Control
1.
Panel Assembly, Remove and Re-install) and the
display module. Remove the display module rear
cover and the key.
SCREWS
SWITCH
ASSEMBLY
NOTE: In this illustration, the control board insulator has
been removed for clarity.
Remove three Phillips head screws and lift the switch
2.
assembly away from the housing.
Noting their locations, transfer the wires to the
3.
replacement switch.
Installation is the reverse of removal.
4.
Interlock Switch Assembly
REMOvE AND RE-INSTALL
The interlock switch assembly is a safety feature. The
switch prevents the compactor from operating unless the
door is safely closed.
Remove the control panel assembly from the unit (see
1.
Control Panel Assembly, Remove and Re-install).
SCREWS
WIRES
Noting their locations, transfer the wires to the
2.
replacement switch assembly.
Remove two Phillips head screws and the interlock
3.
switch assembly from the display panel.
Installation is the reverse of removal.
4.