background image

Page 2

MODEL  744SFL  

PLAN THE INSTALLATION

The unit can be installed anywhere between ceiling joists using 

mounting brackets provided. Install in a flat ceiling only.

Typical Installation

INSTALLATION

2. Mark mounting location.

Position unit between joists and extend mounting brackets. 
IMPORTANT: Position brackets so there will be an 1/8” gap 
between bottom of housing and ceiling material.
 Mark the top 
of keyhole slot on all four mounting brackets.

The unit must not be installed above or inside the cooking area shown.

Do not install in a cooking area.

1/8" GAP

1. Install mounting brackets.

Slide the adjustable mounting brackets into the bracket channels 
on the housing.
Bend the tabs on the cardboard protector and insert protector 
into opening in housing.
NOTE: The cardboard protector shields the inside of the housing 
from drywall spray and construction dust. Do not remove it until 
after construction is completed.

CARDBOARD PROTECTOR

3. Pound in nails.

Remove unit temporarily, and pound nails partially into joists at 
all four marked locations.

Cooking

Equipment

Floor

COOKING AREA

Do not install above or

inside this area.

45

o

45

o

NOT FOR USE IN

A COOKING AREA.

The ducting from this fan to the outside of the building has a strong 

effect on the air flow, noise and energy use of the fan. Use the 

shortest, straightest duct routing possible for best performance, 

and avoid installing the fan with smaller ducts than recommended. 

Insulation around the ducts can reduce energy loss and inhibit 

mold growth. Fans installed with existing ducts may not achieve 

their rated airflow.
Use a roof cap or wall cap that has a built-in damper to reduce 

backdrafts.
Plan to supply the unit with proper line voltage and appropriate 

power cable.

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

TRIM RING / BAFFLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR &

4” ROUND

DUCTWORK

*Purchase

separately.

INSULATION* 

(Place around and 

over Fan Housing.)

ROOF CAP*

(with built-in

damper)

FAN

HOUSING

POWER

CABLE*

4-IN. ROUND

DUCT*

4-IN.

ROUND

ELBOWS*

Seal gaps

around

Housing.

Seal duct

joints with

tape.

OR

Keep duct

runs short.

   WALL CAP* 

(with built-in

damper)

Summary of Contents for 744SFL

Page 1: ...eration by turning on shower or other humidity source until fan turns on 7 Repeat above steps if necessary TIMER ADJUSTMENT This humidity sensing fan has a timer It is user adjustable from 5 to 60 min...

Page 2: ...unit temporarily and pound nails partially into joists at all four marked locations Cooking Equipment Floor COOKING AREA Do not install above or inside this area 45o 45o NOT FOR USE IN A COOKING AREA...

Page 3: ...ows the power cable to enter unit horizontally or vertically 7 Connect wiring Unit can be wired from outside of housing as shown Use UL approved connectors to wire per local codes FINISHED CEILING MAT...

Page 4: ...ries such as speed controls that may be purchased separately and installed with the Fan The limited warranty period for replacement parts and for Fans repaired or replaced under this limited warranty...

Page 5: ...courant et v rifiez le fonctionnement de l appareil en faisant couler la douche ou une autre source d humidit jusqu ce que le ventilateur d marre 7 R p tez les tapes ci dessus au besoin R GLAGE DE LA...

Page 6: ...e doit pas tre install au dessus ou l int rieur de la zone de cuisson illustr e Ne pas installer dans une zone de cuisson Appareil de cuisson Plancher ZONE DE CUISSON Ne pas installer au dessus ou l i...

Page 7: ...c blage peut tre effectu l ext rieur du bo tier tel qu illustr Utilisez des connecteurs homologu s UL pour effectuer le c blage conform ment aux codes locaux COMMANDE 2 FONCTIONS VENDUE S PAR MENT OP...

Page 8: ...rantie limit e pour les pi ces de rechange et pour les ventilateurs r par s ou remplac s en vertu de la pr sente garantie se poursuivra pendant le reste de la p riode de garantie originale CETTE GARAN...

Page 9: ...MANUAL CON APAGADO PROGRAMADO o encendiendo una fuente de humedad hasta que el ventilador se prenda 7 Revise el ajuste del temporizador con un reloj despu s de apagar la fuente de humedad si la encend...

Page 10: ...nstale nicamente en un cielo raso plano Instalaci n t pica No se debe instalar la unidad sobre el rea donde cocine mostrada ni dentro de ella No instale el equipo en un rea donde cocine Equipo de coci...

Page 11: ...l o vertical 7 Conecte el cableado El cableado de la unidad puede hacerse desde afuera de la cubierta tal como se muestra Realice el cableado con conectores aprobados por UL y en cumplimiento de los c...

Page 12: ...mparas Esta garant a no cubre accesorios como controles de velocidad que pueden comprarse por separado e instalarse con el ventilador El periodo de garant a limitada para las piezas de repuesto y para...

Reviews: