Broan 744C Instructions Manual Download Page 4

®

Page 4

MODEL 744C

SERVICE PARTS

KEY NO.

PART NO.

DESCRIPTION

1

97014185

Damper / Duct Connector

2

97016382

Housing Assembly

3

98003036

Mounting Bracket (4 req.)

4

98005512

Wiring Adaptor Plate

5

99524804

Blower Wheel *

6

99524805

Motor Bracket / Venturi *

7

99080557

Motor *

97016454

Motor / Motor Bracket Assembly

(includes Key Nos. 6 & 7) *

8

99271323

Receptacle

9

99271322

Thermal Protector

10

99420551

Plastic Wire Clip

11

99770033

Lamp Socket

12

97016664

Lamp Bracket

97016665

Lamp Bracket Assembly

(includes Key Nos. 8 thru 12)

13

99524802

Trim Ring / Baffle with Springs

14

99525160

Baffle Springs (2 req.)

3

2

8

1

5

9

10

12

11

4

99043574A

Order replacement parts by PART NO. - not by KEY NO.

* Lamp Bracket Assembly must be removed to service these

parts.

9. Attach trim ring / baffle to housing.

Remove the cardboard protector from inside the housing collar.

Insert one end of each spring into the holes on the lamp bracket.
Center trim ring / baffle in ceiling opening.

10. Install bulb.

CAUTION - RISK OF FIRE:
75W MAX. LAMP

Use R30, BR30, PAR30L, or PAR30LN lamps only (75W Max.).

For wet locations (tub or shower) - use PAR30L or PAR30LN
(75W Max.) lamp only. Use no other lamp types.

Do not install a lamp indentified for use only in enclosed luminaries.

6

7

13

FINISHED

CEILING

MATERIAL

HOUSING

COLLAR

CLEARANCE

HOLE

SPRINGS

TRIM RING /

BAFFLE

LAMP

BRACKET

Lamp Bracket Assembly

must be removed to

service these parts.

14

8. Finish ceiling.

Cut an opening in finished ceiling material for housing collar.

Summary of Contents for 744C

Page 1: ...erated using various combinations of on off switches and timer controls Fan and light controlled with single on off switch Fan and light controlled with separate on off switches Fan controlled with on...

Page 2: ...iate power cable Purchase separately INSTALLATION 2 Mark mounting location Position unit between joists and extend mounting brackets IMPORTANT Position brackets so there will be an 1 8 gap between bot...

Page 3: ...apping screw can be used to join extended brackets together and create a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets 5 Attach damper duct conne...

Page 4: ...replacement parts by PART NO not by KEY NO Lamp Bracket Assembly must be removed to service these parts 9 Attach trim ring baffle to housing Remove the cardboard protector from inside the housing coll...

Page 5: ...le r installer Pour nettoyer l int rieur du bo tier Enlevez la garniture circulaire d flecteur et nettoyez l int rieur avec un aspirateur muni d une brosse souple FONCTIONNEMENT Le ventilateur et l cl...

Page 6: ...et allongez les brides de montage IMPORTANT Placez les brides de mani re avoir un cart de 3 mm 1 8 po entre le bas du bo tier et le mat riau du plafond Marquez la partie sup rieure du trou de serrure...

Page 7: ...llong es et solidifier le montage Pour viter les bruits de vibration pincez les brides de montage dans les rainures o elles sont ins r es 5 Fixez le registre raccord de conduit Enclenchez le registre...

Page 8: ...ev pour acc der ces pi ces 9 Fixez la garniture circulaire d flecteur au bo tier Enlevez le protecteur en carton l int rieur du collet du bo tier Ins rez une extr mit de chaque ressort dans les trous...