background image

®

Page 2

MODEL 744C

Two of the most common ways to

connect ductwork to the unit.

ROOF CAP 

**

4-IN. ROUND

ELBOW 

**

4-IN. ROUND

DUCT **

WALL

CAP 

**

Installer: Leave this manual with

the homeowner.

HOUSING

MOUNTING

BRACKET

CEILING

JOIST

POWER

CABLE

TRIM RING / BAFFLE

FINISHED CEILING

4" ROUND

DAMPER/DUCT

CONNECTOR

PLAN THE INSTALLATION

The unit can be installed anywhere between ceiling joists using
mounting brackets provided.

*

 Install in a flat ceiling only.

Typical Installation

The unit will operate most quietly and efficiently when located
where the shortest possible duct run and minimum number of
elbows will be needed.

Plan to supply the unit with proper line voltage and appropriate
power cable.

**

 Purchase separately

INSTALLATION

2. Mark mounting location.

Position unit between joists and extend mounting brackets.
IMPORTANT: Position brackets so there will be an 1/8” gap
between bottom of housing and ceiling material.
  Mark the top
of keyhole slot on all four mounting brackets.

COOKING AREA

Do not install above

or inside this area

Cooking

Equipment

Floor

45

45

The unit must not be installed above or inside the cooking area
shown.

Do not install in a cooking area.

*

1/8" GAP

1. Install mounting brackets.

Slide the adjustable mounting brackets into the bracket channels
on the housing.

Bend the tabs on the cardboard protector and insert protector
into opening in housing.

NOTE: The cardboard protector shields the inside of the housing
from drywall spray and construction dust. Do not remove it until
after construction is completed.

CARDBOARD PROTECTOR

Summary of Contents for 744C

Page 1: ...erated using various combinations of on off switches and timer controls Fan and light controlled with single on off switch Fan and light controlled with separate on off switches Fan controlled with on...

Page 2: ...iate power cable Purchase separately INSTALLATION 2 Mark mounting location Position unit between joists and extend mounting brackets IMPORTANT Position brackets so there will be an 1 8 gap between bot...

Page 3: ...apping screw can be used to join extended brackets together and create a rigid mount To ensure a noise free mount crimp the bracket channels tightly around mounting brackets 5 Attach damper duct conne...

Page 4: ...replacement parts by PART NO not by KEY NO Lamp Bracket Assembly must be removed to service these parts 9 Attach trim ring baffle to housing Remove the cardboard protector from inside the housing coll...

Page 5: ...le r installer Pour nettoyer l int rieur du bo tier Enlevez la garniture circulaire d flecteur et nettoyez l int rieur avec un aspirateur muni d une brosse souple FONCTIONNEMENT Le ventilateur et l cl...

Page 6: ...et allongez les brides de montage IMPORTANT Placez les brides de mani re avoir un cart de 3 mm 1 8 po entre le bas du bo tier et le mat riau du plafond Marquez la partie sup rieure du trou de serrure...

Page 7: ...llong es et solidifier le montage Pour viter les bruits de vibration pincez les brides de montage dans les rainures o elles sont ins r es 5 Fixez le registre raccord de conduit Enclenchez le registre...

Page 8: ...ev pour acc der ces pi ces 9 Fixez la garniture circulaire d flecteur au bo tier Enlevez le protecteur en carton l int rieur du collet du bo tier Ins rez une extr mit de chaque ressort dans les trous...