17
Open windows and doors
Do not light any gas appliance
Do not use any electrical appliance or switches
Do not use the telephone in your home
Leave the building; shut off the domestic gas supply valve (beside your meter)
POINTS OF SAFTEY—To the Customer /Home-Owner
WHAT DO YOU DO IF YOU SMELL GAS
*
Lighting your gas fire using electronic or remote ignition systems may vary as per manufacturer instructions
Broadys recommend annual servicing of your gas fire by an approved Broadys dealer Gas Fitter.
External surfaces should be dusted with a damp, lint-free cloth when the fire is cold.
Broadys provide 12 months warranty from the date of purchase, for domestic or commercial installations
This Warranty Covers :
Replacement Parts and Labour for Gas Control Components due to Manufacturing Defects Only.
Repair or Replacement of the Burner or Firebox Components due to Manufacturing Defects Only.
Warranty cover will be considered void if the product is subject to incorrect installation, failure to operate the appliance in accordance with the
supplied instructions and specifications or is subject to damage or misuse beyond the expected conditions of normal use.
All Installations and servicing must be carried out by and approved Broady’s dealer or Gas Fitter.
Your Broady`s Gas Decorative Fire operates on the principle of dual radiant and convected heat. Therefore it is important to observe the following precautions associated
with any heating appliance or open fire.
•
Do not cover or restrict the fireplace upper or lower vents in any way as this may result in a build-up of hazardous gases within the room.
•
The fire is not intended for the drying of clothing, bedding etc.
•
Avoid installing this appliance in high traffic areas, strong draughts or near drapes or furniture.
•
The use of an approved fireguard is recommended for the protection of young children.
•
Avoid using aerosols when the appliance is operating.
•
Avoid anyone leaning against or lying directly in front of the fire while operating.
•
Do not place anything objects into or against the gas fire at any stage.
•
The fire may release a small amount of smoke on its first start up which may take 1or 2 hours to dissipate . This is part of the curing process so ensure there is
adequate ventilation within the room.
•
Always use a registered Gas Fitter or Electrician for installing and maintenance work
•
Always use certified gas cylinders that have been tested and are safe to use.
•
Never modify your gas appliance or its settings from those specified by the manufacturer.
APPLIANCE SAFETY
Any gas fire appliance shall comply with the safety requirements of NZS 5262 or any one of the Standards listed or referred to in "related docu-
ments" of this Standard.
ELECTRONIC CONTROL SYSTEMS
Any gas fire appliance fitted with manual or programmable electronic control systems shall be tested and/or approved by a recog-
nised person or authority.
MAINTENANCE : All burner setting, Coals placement, Vermiculite is to be checked and set in accordance with
this specification by the service person/Gas fitter