background image

MC

-

S400

2

Management Center

Quick Start Guide

To deploy the appliance and connect cables:
1. Deploy the ProxySG appliance per the instructions in the 

ProxySG Quick Start Guide

.

2. Connect an Ethernet cable to the MC

-

S400’s

 

LAN 1:0

 

port and connect the other end of the cable to the LAN 

switch. The appliance auto-negotiates 10/100/1000 

Base-T speed and duplex settings.

3. Connect an Ethernet cable to the MC

-

S400’s 

MGMT 0:0

 

port and connect the other end of the cable to the man

-

agement network switch.

4. Connect the included null-modem cable to the 

MC

-

S400’s 

DB9 Serial

 port and connect the other end 

of the cable to a serial terminal or workstation with termi

-

nal emulation software. The serial connection is used to 

perform the appliance’s initial configuration.

5. Connect the included power cords to the MC

-

S400’s 

power inlets and connect the other ends of the power 

cords to a power source.

3 — Power On the Appliance and 

Verify LEDs

To verify the appliance is operational:
1. Confirm the appliance’s power cords are securely 

connected to a power source.

2. If the appliance does not automatically power on, press 

the rear soft power switch.

NOTE: 

The state of the appliance’s soft power switch (on 

or off) is retained when power is removed. This may ne

-

cessitate pressing the power switch when reapplying 

power to the appliance.

3. As the appliance boots, verify the following:

The power LED turns amber.

Near the end of the boot cycle, the Power LED alter

-

nates between amber and green, indicating an uncon

-

figured state.

After the boot cycle has completed, the LCD panel dis

-

plays information about the appliance, such as model, 

serial number, and IP address, which can be scrolled 

through with the Right and Left Arrows.

Following the initial configuration and licensing, the 

Power LED turns green.

During operation, the front-panel status LEDs indicate the 

following states:

4 — Perform the Initial Configuration

NOTE: 

To initialize the appliance, you need the following: 

appliance IP address; primary DNS server IP address; 

default gateway IP address; subnet mask; console 

password for advanced CLI commands.

To perform the initial configuration for the appliance:
1. Confirm the appliance’s 

DB9 Serial

 port is connected to 

a serial terminal or workstation with terminal emulation 

software.

2. Open a terminal emulation program, such as Microsoft 

HyperTerminal®, PuTTY, Tera Term, or ProComm™, 

and configure it to use the following settings:

3. Power on the appliance (if it is not already powered on) 

and, when prompted, press 

Enter

 three times.

4. When prompted, enter network configuration parame

-

ters. If the appliance is connected to a network, the Con

-

figuration Wizard attempts to verify the DNS server 

address and auto-detect link settings.

NOTE: 

The first time the MC

-

S400 boots, it requires approx

-

imately 5 minutes to initialize the RAID array, after which the 

appliance begins a one-time RAID synchronization that 

takes approximately 4–5 hours. You can view the status of 

LED

Color

Description

Power 

Status

Off

Powered off or no power present

Amber

Booting

Amber/green 

alternating

Not yet initialized

Green

Powered on and configured

System 

Status

Off

Powered off or no power present

Green

Normal

Amber

System fault or not yet licensed

Amber blinking

Critical fault

Baud rate:

 9600 bps

Data bits:

 8

Parity:

 none 

Stop bits:

 1

Flow control:

 none