61
MicroSYNC Configuration Bytes
There are two bytes that carry all of the MicroSYNC Configuration information.
Configuration Byte #1
Configuration Byte #2
Bit 0
Vertical Blanking
Bit 0
Genlock Mode
0 = Narrow
0 = Auto
1 = Wide
1 = Manual
Bit 1
Synchronizer Mode
Bit 1
Manual Genlock Mode
0 = 4-Field
0 = External
1 = Frame
1 = Internal
Bit 2
Output Burst
Bit 2
Comb Filter Mode
0 = Burst ON
0 = Normal
1 = Burst Off
1 = Monochrome
Bit 3
Manual Burst
Bit 3
Input Lock Mode
0 = ON
0 = Auto Lock
1 = OFF
1 = Manual Lock
Bit 4
Process
Bit 4
Manual Input Lock
0 = Process
0 = Burst Lock
1 = Bypass
1 = Manual Lock
Bit 5
Hot Switch
Bit 5
Clamp Speed
0 = Enable
0 = Normal
1 = Disable
1 = Fast
Bit 6
Hot switch Mode
Bit 6
Forced Black Mode
0 = Frame
0 = Normal
1 = Black
1 = Black
Bit 7
Black Clip
Bit 7
Hot Frame Mode
0 = Enable
0 = Off
1 = Disable
1 = On