SS 4.1 MLR/RJ Installation and Operation Manual
OPERATION
Configuration Jumpers
JP4:
Disabled = Front panel enable switch defeated. (Factory default)
Enabled = Front panel ENABLE push button active and the enable LED is
illuminated.
NOTE: The enable push button must be held in/closed to operate any of the
other front panel push buttons and isn’t associated with any of the remote con-
trol functions.
Configuration DIP-switch Setup
Follow the tables below for SW9 dip-switch configuration options.
Note: To select an input at power-up with SW9-6 ON, hold down the push-but-
ton for the desired input channel or mute until the front panel LEDs flash.
• Remote control operation mode: Pulse 1-IN to select channel 1, pulse IN-2 to
select channel 2, pulse IN-3 to select channel 3, pulse IN-4 to select input 4, pulse
the “M-IN” (mute) pin to turn off all channels.
• PIP/Trigger mode: activity on any of the PIP inputs will generate a serial status
string in the PIP format. For use with automation software.
Note: After changing any DIP-switch, please repower the unit.
Note: * Denotes factory default setting.