REMOTE CONTROL
The AES-200 is fully remote controllable via a rear panel 9 pin DE connector. In addition to
remote control of the channel switching function, channel status is available. The control pins (3
and 4) are ground start and require only a momentary connection to ground for actuation. The
status pins (7 and 8) are dry isolated contacts that provide a closure to status common pin
number (6) that can be user configurable for either voltage or ground status. The status contacts
are rated at 24 VDC/2 amperes. Do not attempt to use 110 VAC for status indications without the
use of an external relay. Refer to table 1 below for complete pin out information for the rear
panel D connector.
TABLE 1 : Remote Control Pinout
PIN # FUNCTION
1 +15 VDC (200 mA MAX.)
2 NC
3 Control #1 Input
4 Control #2 Input
5 NC
6 Status Common
7 Status Channel #1 “ON”
8 Status Channel #2 “ON”
9 Ground