4.0  MAINTENANCE AND TROUBLESHOOTING

4.1  Maintenance

There is no operator maintenance other then keeping the units
clean.  However, observe the following light indicators to make
sure that the unit is working properly:

4.2  Troubleshooting

If the LBC-HDMI-T/R-WP units do not operate properly after
installation, check for possible cable breaks, loose connections,
and incorrect cable connections.  If problems persist that may
be fiber related, contact BCI at 1-800-214-0222 for further
assistance.

For electrical problems, perform the following troubleshooting
procedures:

1.

If the POWER indicator is OFF, check for the following:

a.

The line cord is plugged into the unit and your outlet
has power.

2.

If the POWER indicator is ON, but the Link indicator is
OFF, check for the following:

a.

Make sure the appropriate cables are being used.

b.

Cable and cable connectors are not broken.

c.

For each unit, the transmit (TX) cable is connected to
the other unit’s receiver (RX).

3.

If the POWER indicator and Link indicator are ON, but
the channels are not operating, then:

a.

Check to see that the attached user equipment is turned
on.

b.

Both ends of the link are connected to the corresponding
equipment and to the same corresponding channel port.

Summary of Contents for Link Bridge LBC-HDMI-R-WP

Page 1: ...DBASET TRANSMISSION SYSTEM BCI reserves the right to make changes to the products described herein without prior notice or consent No liability is assumed as a result of their use or application All r...

Page 2: ...D COMPLIANCE DECLARATIONS PLEASE OBSERVE THE FOLLOWING SAFETY PRECAUTIONS SURGE PROTECTION DEVICE RECOMMENDED This product contains sensitive electrical components that may be damaged by electrical sp...

Page 3: ...UNTING 8 2 2 CABLING AND CONNECTORS 8 2 3 HDMI VIDEO INTERFACE 9 2 4 CAT 5E 6 TRANSMISSION CONNECTION 10 3 0 DC POWER CONNECTION 11 3 1 IN WALL POWER CAT 5E 6 WIRING INSTRUCTION 12 4 0 MAINTENANCE AND...

Page 4: ...s a 1 gang single input Decora style wall plate transmitter and receiver When the HDMI with active signal is connected the signal will be sent to the compatible HDBaseT receiver automatically In addit...

Page 5: ...cal Support 800 214 0222 6 Front Panel Wall Plate 1 Link Soild red when power up Blinking red amber when HDBT connect without video signal Solid amber when video connection established 2 HDMI In Conne...

Page 6: ...T Transmission System Broadata Technical Support Sales Broadatacom com 7 Rear Panel Wall Plate 1 Power Connect to 24V DC adapter here to power up device 2 HDBaseT Connect RJ45 category cable from HDBa...

Page 7: ...ical installation for the LBC HDMI T R WP pair 2 1 Mounting Before installing the units into your housing make sure there is enough space to pull and connect both the electrical and category cables wi...

Page 8: ...deo connection is the HDMI plug connectors for video input port Use the following instructions to properly connect your component video as illustrated in Figure 2 2 Connect the LBC HDMI T R WP Transmi...

Page 9: ...specified for use with RJ45 connectors Follow the ensuing instructions on installing and connecting the HDBaseT links 1 Ensure the power is off before proceeding with the CAT 5e 6 cable installation 2...

Page 10: ...spikes from occurring thus protecting your LBH HDMI T R WP from sensitive voltage conditions The LBC HDMI T R WP derives power from an external 24VDC power supply or via PoH Power over HDBaseT This p...

Page 11: ...Feed both CAT 5e 6 and power cables through the opening of the wall box and secure the cables with cable clamps to provide strain relief 2 Terminated CAT 5e 6 with RJ45 connector to be directly plugge...

Page 12: ...isted ITE Power Supply marked rated as LPS or Limited Power Source Note 2 The installation shall be in accordance with the applicable provisions of the National Electrical CodeANSI NFPA70 Article 725...

Page 13: ...ct BCI at 1 800 214 0222 for further assistance For electrical problems perform the following troubleshooting procedures 1 If the POWER indicator is OFF check for the following a The line cord is plug...

Page 14: ...k BridgeTM HDMI Wall Plate HDBaseT Transmission System Broadata Technical Support Sales Broadatacom com 15 c Cable connections at both channels are securely fastened to each connector Turn the power o...

Page 15: ...4K2K and 1080p 60Hz or 1920x1200 60Hz Connector HDMI Female Plug Protocol DDC EDID HDCP Compatible Transmission Cable Type Single CAT 5e 6 Number of cables 1 Connector RJ45 Max Distance 70m 230 ft Ph...

Page 16: ...DMI T R WP System contains no user serviceable components If you have a problem with your unit please contact the Customer Service Department To facilitate our return repair processing please contact...

Page 17: ...not include malfunctions or failure resulting from misuse abuse neglect alterations electrical power problems usage not in accordance with product instructions improper installation or damage determi...

Page 18: ...LBC HDMI T R WP User s Manual Link BridgeTM HDMI Wall Plate HDBaseT Transmission System Broadata Technical Support Sales Broadatacom com 19...

Page 19: ...LBC HDMI T R WP User s Manual Link BridgeTM HDMI Wall Plate HDBaseT Transmission System Broadata Technical Support 800 214 0222 20...

Page 20: ...Communications Inc 2545 West 237th Street Suite K Torrance CA 90505 1 800 214 0222 310 530 1416 310 530 5958 Facsimile e mail CustomerService Broadatacom com Website www broadatacom com 60000 LBC HDM...

Reviews: