2.4 In-Wall Power/Fiber Wiring Instruction
The in-wall power/fiber installation for the LBO-DVI-EAD-WP (wall plate
version) must confirm national and local electrical codes, e.g., UL junction
boxes shall be used and DC power source shall not exceed product
rated range (+12VDC @ 1.5A). Follow the following steps for power/
fiber installation:
1.
As shown in Figure 2-6, feed both fiber and power cables through
the opening of the wall box, and secure the cables with cable
clamps to provide strain relief.
2.
Terminated fiber with SC optical connector to be directly plugged
into the SC connector port of the LBO-DVI-EAD-WP units
(see Figure 2-5).
3.
Before connecting power wire to the LBO-DVI-EAD-WP unit,
make sure power supply is off
. Prepare the Positive (+12V)
and Negative (GND or +12V return), and chassis ground
(CHASSIS to earth ground) tip of the power wire as shown in
Figure 2-7 to be directly plugged into the captive screw +12VDC
connector of the LBO-DVI-EAD-WP units (see Figure 2-6). Make
sure the polarity of the connection is correct. Insulate any
exposed wire shields to prevent short circuits.