18 

 

 

17.0 Glossary 

 
Zone 

One  room  or  a  group  of  rooms;  normally  selected  on  the  basis  of 
usage or that have similar heating or cooling needs.  

 
Controlled Zone 

A zone that is separately controlled by its own zone sensor and zone 
damper. There are as many zone sensors in the home comfort system 
as there are Controlled Zones. 
 

Common Zone

 

A  zone  that  is  not  separately  controlled  by  its  own  sensor  and  zone 
damper.   It  operates  whenever  heating  or  air  conditioning  is  on, 
regardless of the status of any controlled zones. 
 

Constant Zone 

A  predetermined  zone,  typically  the  largest  and  containing  the  return 
air  grille,  is  designated  as  the  Constant  Zone.    The  Constant  Zone 
functions as a Common Zone only during refrigerated cooling mode to 
ensure the minimum cooling airflow requirements are met.  
 

Single Temperature Set Point (STSP) System 

The  zone  temperature  set  point  is  the same  across  all  Touchscreens 
and/or Temperature Sensors.   
 
Your  system  can  control  up  to  four  zones  to  a  single  temperature 
setting.    You  may  operate  the  system  in  MANUAL  or  SCHEDULE 
operation.  In  MANUAL,  you  may  activate  each  zone  as  required.  In 
SCHEDULE operation, select each zone you wish to operate for each 
time and temperature setting in the program schedule. 

 
 
Multi Temperature Set Point (MTSP) System 

The  zone  temperature  set  point  can  be  set  independently  across  all 
Touchscreens and/or Temperature Sensors. 
 
Your  system  can  control  up  to  four  zones  so  that  each  zone  has  its 
own temperature set point.   You may operate the system in MANUAL 
or  SCHEDULE  operation.  In  MANUAL,  you  may  activate  each  zone 
and select the temperature level as required. In SCHEDULE operation, 
select  each  zone  you  wish  to  operate  for  each  time  and  its  own 
temperature setting in the program schedule. 

 

Brivis Touch Controller 

Primary  user  interface  with  Touchscreen  display.  Where  multiple 
Touchscreens  are  installed,  the  “

Master

”  Controller  can  be  identified 

by the letter “

M

” in the bottom right hand corner of the screen.    

 

Brivis Remote Temperature Sensor  

Zone  temperature  sensor  with  an  LED  that  blinks  during 
communication  with  Master  Controller.    Additional  Touchscreens  can 
be used in place of up to 3 x Remote Temperature Sensors.   

 
Sensor 

Both  the  Brivis  Touchscreen  and  Remote  Temperature  Sensors 
function  as  zone  (room)  temperature  sensors  –  in  this  context,  the 
word “

sensor

” in this manual can apply to both.  

 
A  Remote  Temperature  Sensor  can  also  be  used  as  an  Outdoor 
Temperature Sensor. 
 
 
 
 
 

Summary of Contents for Touch

Page 1: ...Brivis Touch Owner s Manual ...

Page 2: ...ms a single Touch Controller with single or multiple room temperature sensors multiple Touch Controllers The Brivis Touch Controller also facilitates either Single Temperature Set Point STSP or Multi Temperature Set Point MTSP control of zoned systems Your Brivis designer installer will advise you on the appropriate configuration and operation of your system Please also refer to any Owner s Manual...

Page 3: ...on 7 6 4 Evaporative Cooling Timer Operation 7 6 5 Evap Timer ON Manual Auto 8 6 6 Evap Timer OFF Manual Auto 9 6 7 Evap Timer Cancel or Change 10 7 0 Zoning where installed 10 7 1 Single Temperature Set Point Zoning STSP 10 7 2 Multi Temperature Set Point Zoning MTSP 10 8 0 Menu 11 9 0 User Preferences 11 9 1 System Lockout Control 12 9 2 General Settings 12 9 3 System Settings 13 9 4 Set Zone Na...

Page 4: ...om temperature sensor active System Mode Run indicator Zones Where Fitted Mode Selector ON OFF Digital Clock Manual or Schedule M Master Controller Day Fan Only mode Display Options or Settings Fan Status Indicator Current System Mode Room Zone Temperature Zone ID where fitted ...

Page 5: ...2 Diagram 3 Refrigerated Cooling Screen Diagram 2 Evaporative Cooling Screen Pump On Fan On Timer On Timer Manual Auto ...

Page 6: ...re comfort level by using the UP DOWN buttons 5 System will run at desired comfort level until turned OFF by pressing the ON OFF button You may access User Preferences and other advanced options by pressing the MENU button 3 0 Fan Operation FAN ONLY With the system OFF standby push the FAN button in the top right hand corner to turn the fan ON If in HEAT or COOL mode the heater fan will turn on If...

Page 7: ...utton turn system on using the ON OFF button and press the Schedule button The system will operate automatically to maintain the desired temperatures as programmed in the program Schedule Advance to next Period If you leave or arrive home early you may skip to the next schedule period by pressing the current period displayed e g The program schedule will automatically resume once one of the follow...

Page 8: ...perature level until turned OFF 5 1 Cooling Program Schedule Operation The Brivis Touch Controller uses default energy saver COOL settings that helps reduce your refrigerated cooling expenses To operate your Refrigerated Cooling system with the program schedule activate the Controller by touching the LCD screen select COOL using the MODE button turn system on using the ON OFF button and press the ...

Page 9: ...on is pressed The Temporary period is pressed Temporary Temperature Override To temporarily adjust the temperature simply adjust the temperature level with the UP DOWN arrows The program Schedule will automatically resume once one of the following occurs The next time period begins The Cancel button is pressed The word Temporary will flash on the screen Diagram 7 Cooling ON Schedule home screen Di...

Page 10: ...able the pump The FAN icon will remain illuminated the PUMP icon will not Only the fan will be running in this mode 6 3 Evaporative Cooling Auto Operation To operate your Evaporative Cooling system so that it automatically maintains your desired comfort level activate the Controller by touching the LCD screen select EVAP using the MODE button turn system ON using the ON OFF button press the AUTO b...

Page 11: ...s become available to change Fan Speed Low to High Pump ON or OFF Press the PUMP button to change Set On Time within next 24 hours To save settings and return to the home OFF screen press Done To cancel Timer setting press BACK For ON Timer in AUTO mode the below configuration options become available to change Comfort Level Dark blue is cooler Set On Time within next 24 hours Diagram 12 EVAP mode...

Page 12: ... Diagram 15 6 6 Evap Timer OFF Manual Auto With the system ON in either MANUAL or AUTO mode press the Timer button refer Diagrams 10 11 For OFF Timer the below configuration option becomes available to change Set Off Time within next 24 hours To save settings and return to the ON screen press Done To cancel Timer setting press BACK Diagram 15 EVAP OFF with ON Timer Set Diagram 16 Set OFF Timer Dia...

Page 13: ...re Sensors may be fitted The following information applies to HEATING or REFRIGERATED COOLING systems only i e not Evaporative Systems Please ensure your dealer has provided you with details on zone identification the capabilities of your heating and cooling system and the maximum or minimum number of zones that can be operated simultaneously for heating or cooling design conditions 7 1 Single Tem...

Page 14: ... the homeowner these are 1 User Preferences 2 Clean Screen 3 Schedule 4 Set Day Time Refer Diagram 19 Note Once you access the MENU Screen and select a configuration option if no button is pressed for 60 seconds the Touch will exit the configuration mode and return to normal operation this applies to all options other than SCHEDULE 9 0 User Preferences When the User Preferences button is pressed o...

Page 15: ... to enter the PIN code to unlock the system To modify the User PIN press either PIN Number 1 or PIN Number 2 Pressing either one of these will allow the PIN to be modified and a key pad will appear as shown in Diagram 22 Once the new PIN has been entered press OK to accept 9 2 General Settings When the General Settings button is pressed on any Brivis Touch controller the general settings can be vi...

Page 16: ...e AUTO schedule For Schedule Day Grouping Heat Cool the options are Weekdays Weekends Same for all days Set days individually The Schedule Pre Sleep Option allows this period to be ON or OFF when programming the AUTO schedule The Temperature Display Scale allows the temperature scale displayed on the home screen to be either Celsius or Fahrenheit Diagram 26 System Settings Diagram 24 Active backli...

Page 17: ...me change refer Diagram 28 Press the Done button once complete and the zone name will be changed refer Diagram 29 10 0 Clean Screen The screen displayed after pressing the Clean Screen button allows no user input reverting back to the configuration menu screen after 30 seconds This allows the Brivis Touch Controller screen to be cleaned without affecting any operation refer Diagram 30 Diagram 27 N...

Page 18: ... set a period to OFF reduce the temperature for that period DOWN to the minimum setting Repeat this for all day grouping options Weekdays Weekends shown in Diagrams 29 30 if installed Once complete press BACK to save and exit back to the MENU screen Only the zones installed for the heating cooling system are displayed and can be enabled or disabled for each period by pressing the relevant zone but...

Page 19: ... the BACK button does not save the changes and returns to the configuration menu screen 13 0 Service Notification Message When the operating hours logged for an appliance exceeds the predetermined period the Brivis Touch Controller displays the following Diagram 33 Set Day Time The Spanner icon appears flashing at one second intervals The Alert icon is displayed with the Alert text flashing at one...

Page 20: ...e On board diagnostics help determine the source of any faults If a lockout fault is detected the yellow Alert will flash refer Diagram 36 Press the Alert icon to display details of the fault refer Diagram 37 If the system turns off completely you may reset the system by pressing the Reset button refer Diagram 37 If normal operation does not resume please call Brivis Service for assistance Inform ...

Page 21: ...HEDULE operation select each zone you wish to operate for each time and temperature setting in the program schedule Multi Temperature Set Point MTSP System The zone temperature set point can be set independently across all Touchscreens and or Temperature Sensors Your system can control up to four zones so that each zone has its own temperature set point You may operate the system in MANUAL or SCHE...

Page 22: ...19 Notes ...

Page 23: ...20 Notes ...

Page 24: ... brivis com au email sales brivis com au Brivis New Zealand Distributor Warm Air Ltd 69 Marsden Street Lower Hutt 5010 New Zealand PO Box 38523 Wellington Mail Centre Wellington 5043 New Zealand 0800 WARMAIR 0800 9276 247 Ph 64 04 920 1670 Fax 64 04 920 1681 www warmair co nz Brivis South Africa Distributor Lorenz and Associates Northlands Deco Park Cnr Witkoppen and Newmarket Roads North Riding J...

Reviews: