Thank  you  for  buying  this  BRITEQ

®

  product.  To  take  full  advantage  of  all  possibilities  and  for  your  own 

safety, please read these operating instructions very carefully before you start using this unit.  
 

FEATURES 

  A  reliable  100Watt  "COB"  LED-based  black  light  with  more  output  than  the  traditional  UV400  Black  light 

and with many advantages! 

  DMX control via 1 or 2channels: d strobe channel 

  Can be dimmed from 0% to 100% 

  Sound activated mode with internal mic.  

  Variable Strobe  

  Master/slave mode for bigger venues 

  Extruded black aluminium housing with strong bracket 

  No fragile, easy breakable lamps: perfect for hiring companies! 

  Optional IR-remote control for easy operation! 

 

BEFORE USE 

  Before you start using this unit

, please check if there’s no transportation damage. Should there be any, do 

not use the device and consult your dealer first.  

 

Important: 

This  device  left  our  factory  in  perfect  condition  and  well  packaged.  It  is  absolutely  necessary 

for the user to strictly follow the safety instructions and warnings in this user manual. Any damage caused 
by mishandling is not subject to warranty. The dealer will not accept responsibility for any resulting defects 
or problems caused by disregarding this user manual. 

  Keep  this  booklet  in  a  safe  place  for  future  consultation.  If  you  sell  the  fixture,  be  sure  to  add  this  user 

manual. 

 
Check the contents: 

Check that the packing contains the following items: 

  Operating instructions 

  LED UV-GUN 100W 

 

SAFETY INSTRUCTIONS: 

 

CAUTION:

  To  reduce  the  risk  of  electric  shock,  do  not  remove 

the  top  cover.  No  user-serviceable  parts  inside.  Refer  servicing 
to qualified service personnel only. 

 

The lightning flash  with arrowhead symbol  within the  equilateral triangle  is intended to alert  the 
use or the presence of un-

insulated “dangerous voltage” within the product’s enclosure that may 

be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of  important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This symbol means: Safety Class I appliance. 

 

This  symbol  determines:  the  minimum  distance  from  lighted  objects.  The  minimum  distance 
between light-output and the illuminated surface must be more than 0.1 meter 

Summary of Contents for LED UV-GUN 100W

Page 1: ......

Page 2: ......

Page 3: ... by mishandling is not subject to warranty The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual Keep this booklet in a safe place for future consultation If you sell the fixture be sure to add this user manual Check the contents Check that the packing contains the following items Operating instructions LED UV GUN 100W SAFETY INSTRU...

Page 4: ...The electrical installation should be carried out by qualified personal only according to the regulations for electrical and mechanical safety in your country Check that the available voltage is not higher than the one stated on the unit The power cord should always be in perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the manufac...

Page 5: ...must be carried out by qualified service personal only Improper installation can result in serious injuries and or damage to property Overhead rigging requires extensive experience Working load limits should be respected certified installation materials should be used the installed device should be inspected regularly for safety Make sure the area below the installation place is free from unwanted...

Page 6: ... slaves to SLAU Make sure that all units are connected to the mains Refer to chapter HOW TO SETUP for more information Done Electrical installation for two or more units in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units with a good quality balanced DMX cable To prevent stran...

Page 7: ...d FrEE output based on the last valid DMX signal is kept on the projector nuLL BLACKOUT mode output turns black while no DMX is detected Press ENTER to confirm dinn STANDALONE use without DMX control dimmer mode Used to adjust the output manually Press the buttons until dinn is shown on the display Press ENTER to confirm Use the buttons to change the output between 00 no output and 99 full output ...

Page 8: ... DMX mode to learn how to do this don t forget to address all units properly Connect all units to the mains and turn on the DMX controller Since each unit has its own DMX address you can control them individually Remember that each unit uses 1 or 2 DMX channels depending on the DMX mode you have selected in the menu See the different DMX charts below 1CH MODE Channel 1 Dimmer 000 255 0 100 2CH MOD...

Page 9: ...r air jet The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts ...

Page 10: ......

Reviews: