MAINTENANCE

 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 

Mains Input: 

110-240Vac, 50/60Hz 

Power consumption:

 

95 Watt 

Fuse: 

250V 2A slow blow (20mm glass) 

Sound Control: 

Internal microphone 

DMX connections: 

XLR 3pin  

LEDs:

 

100W COB UV LED (

λ = 395 ~ 405nm) 

Beam angle: 

60° 

Size:

 

see drawing  

Weight:

 

4,1 kg 

        

 

 

Every information is subject to change without prior notice 

You can download the latest version of this user manual on our website: www.briteq-lighting.com 

 

Summary of Contents for LED UV-GUN 100W

Page 1: ......

Page 2: ......

Page 3: ... by mishandling is not subject to warranty The dealer will not accept responsibility for any resulting defects or problems caused by disregarding this user manual Keep this booklet in a safe place for future consultation If you sell the fixture be sure to add this user manual Check the contents Check that the packing contains the following items Operating instructions LED UV GUN 100W SAFETY INSTRU...

Page 4: ...The electrical installation should be carried out by qualified personal only according to the regulations for electrical and mechanical safety in your country Check that the available voltage is not higher than the one stated on the unit The power cord should always be in perfect condition Switch the unit immediately off when the power cord is squashed or damaged It must be replaced by the manufac...

Page 5: ...must be carried out by qualified service personal only Improper installation can result in serious injuries and or damage to property Overhead rigging requires extensive experience Working load limits should be respected certified installation materials should be used the installed device should be inspected regularly for safety Make sure the area below the installation place is free from unwanted...

Page 6: ... slaves to SLAU Make sure that all units are connected to the mains Refer to chapter HOW TO SETUP for more information Done Electrical installation for two or more units in DMX mode The DMX protocol is a widely used high speed signal to control intelligent light equipment You need to daisy chain your DMX controller and all the connected units with a good quality balanced DMX cable To prevent stran...

Page 7: ...d FrEE output based on the last valid DMX signal is kept on the projector nuLL BLACKOUT mode output turns black while no DMX is detected Press ENTER to confirm dinn STANDALONE use without DMX control dimmer mode Used to adjust the output manually Press the buttons until dinn is shown on the display Press ENTER to confirm Use the buttons to change the output between 00 no output and 99 full output ...

Page 8: ... DMX mode to learn how to do this don t forget to address all units properly Connect all units to the mains and turn on the DMX controller Since each unit has its own DMX address you can control them individually Remember that each unit uses 1 or 2 DMX channels depending on the DMX mode you have selected in the menu See the different DMX charts below 1CH MODE Channel 1 Dimmer 000 255 0 100 2CH MOD...

Page 9: ...r air jet The cleaning of internal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit s optics Clean with a soft cloth using normal glass cleaning products Always dry the parts ...

Page 10: ......

Reviews: