Briteq EXPO CANNON Operation Manual Download Page 9

ENGLISH 

 

USER MANUAL

 

 
BRITEQ

®

 

7/9 

EXPO CANNON 

 

Factory: 

standard factory settings. 

 

USER  x:

  you  can  adapt  the  factory  settings  and  save  the  new  parameters  as  your  personal  USER-

settings. 

  Press the ENTER button:  

 

Factory was selected: 

the display shows “LOAD”

 

 Press the ENTER button and u

se ▲/▼ buttons to confirm YES / NO 

 Press the ENTER button to confirm. 

 

USER Def. was selected:

 

the display shows “LOAD” 

 Use 

▲/▼ buttons to select LOAD / SAVE 

 Press the ENTER button and u

se ▲/▼ buttons to confirm YES / NO 

 Press the ENTER button to confirm. 

 

SAVE was selected:

 the current settings of the setup menu are saved to memory. 

 

LOAD was selected:

 the previously saved settings are loaded. 

 
Set of Factory default settings: 

PARAMETER name 

FACTORY defaults 

USER defaults 

CHANNEL mode 

2CH (D+S) 

Current setting in the menu 

NO DMX mode 

Freeze 

Current setting in the menu 

DIM Curve 

Square 

Current setting in the menu 

Dimmer Speed 

100 (440ms) 

Current setting in the menu 

AUTO LOCK Menu 

OFF 

Current setting in the menu 

 

FIRMWARE 

Used to show the current version of the firmware. 

  Press the MENU button  until the FIRMWARE is showing on the display. 

 

LED TEMP  

Shows the actual temperature of the LEDs. 

 

Press the ▲/▼ buttons until the desired function is showing on the display. 

  Press the ENTER button: the LED temperature is shown. 

 
The firmware of this unit can be upgraded using a special upgrade tool with Windows

®

 software. (separately 

available from Briteq). 
Each time the projector is switched on, the display shows 

UPDATE Wait ….: while this message shows on 

the display you can start the update using our special upgrade tool. More information about this can be found 
in the user manual of the upgrade tool and / or our website: 

www.briteq-lighting.com

 

 

RDM FUNCTIONS / REMOTE SETUP 

RDM

 

means  “

R

emote 

D

evice 

M

anagement”.  This  projector  works  with  a  brief  set  of  RDM-functions  which 

means  that  it  can  setup  a  bi-directional  communication  with  an  RDM-compatible  DMX-controller.  Some  of 
these functions are briefly explained below, others will be added in the future. 

  The  DMX-

controller  sends  out  a  “discovery  command”,  all  RDM  devices  respond  and  send  their  unique 

device ID.

 

  The DMX-controller asks each RDM device for some basic data so it knows which devices are connected. 

The projector will respond: 

 

Device name:

    

EXPO CANNON 

 

Manufacturer:

    

Briteq

®

 

 

Sensors:

  

 

actual LED temperature 

 

Service hours:   

total used hours since 1

st

 use. 

 

Firmware:

 x.x.x.x 

firmware version of the projector 

 

DMX address:

 xxx 

current DMX start address of the projector 

 

DMX footprint:

 xx 

number of DMX-channels used by the projector 

 

Personality:

 xx   

current personality or DMX-working mode used by the projectors 

  The  DMX-controller  can  send  certain  commands  to  each  RDM  device  which  allow  remote  setup  of  the 

units. Thanks to this the projectors can be setup remotely.  

 

Summary of Contents for EXPO CANNON

Page 1: ......

Page 2: ......

Page 3: ...ED refresh rate The lamp behavior can be continuously adjusted from led to halogen Four dimmer curves linear square inverse square S curve In case of DMX failure you can choose between blackout and fr...

Page 4: ...rd Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropri...

Page 5: ...d to browse the different menu options or to exit a menu option button used to go to the next menu option or to decrease a parameter value button used to go to the previous menu option or to increase...

Page 6: ...n openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time T...

Page 7: ...ay Press the ENTER button the values can be changed Use buttons to select the desired DMX512 address The last occupied DMX address is also shown makes it easier to set the address of the next unit in...

Page 8: ...e halogen lamp behavior At the same time the light output will be instantaneous while pushing a flash button on your DMX controller LOCKING Used to lock the setup menu against unwanted altering of the...

Page 9: ...are of this unit can be upgraded using a special upgrade tool with Windows software separately available from Briteq Each time the projector is switched on the display shows UPDATE Wait while this mes...

Page 10: ...ller Since each unit has its own DMX address you can control them individually Remember that each unit uses 1 or 2 DMX channels depending on the DMX mode you have selected in the menu See the differen...

Page 11: ...manufacturer Mains Input AC 110V 240V 50 60Hz Power consumption 380 Watt max Power Factor 94 Fuse 250V T4A 20mm glass DMX connections 3pin XLR male female DMX channels used 1 2 channels Lamp 37pcs CRE...

Page 12: ......