EXPO CANNON 

OVERHEAD RIGGING 

 

Important:

 

The  installation  must  be  carried  out  by  qualified  service  personal  only.  Improper 

installation  can  result  in  serious  injuries  and/or  damage  to  property.    Overhead  rigging  requires 
extensive  experience!  Working  load  limits  should  be  respected,  certified  installation  materials 
should be used, the installed device should be inspected regularly for safety.

 

  Make sure the area below  the installation place  is free from unwanted persons  during rigging, de-rigging 

and servicing. 

  Locate  the  fixture  in  a  well  ventilated  spot,  far  away  from  any  flammable  materials  and/or  liquids.  The 

fixture must be fixed 

at least 50cm

 from surrounding walls. 

  The device should be installed out of reach of people and outside areas where persons may walk by or be 

seated. 

 

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s 
weight. 

  Always  use  a  certified  safety  cable  that  can  hold  12times  the  weight  of  the  device 

when installing the unit. This secondary safety attachment should be installed in a way 
that no part of the installation can drop more than 20cm if the main attachment fails. 

  The device should be well fixed; a free-swinging mounting is dangerous and may not 

be considered! 

 

Don’t cover any ventilation openings as this may result in overheating.  

  The  operator  has  to  make  sure  that  the  safety-relating  and  machine-technical 

installations  are  approved  by  an  expert  before  using  them  for  the  first  time.  The  installations  should  be 
inspected every year by a skilled person to be sure that safety is still optimal. 

 
 

ELECTRICAL INSTAL ADDRESSING 

Important:  The  electrical  installation  should  be  carried  out  by  qualified  personal  only, 
according to the regulations for electrical and mechanical safety in your country. 

 
Master / Slave mode:  

Connect the projectors together as shown on the drawing. Please refer to the paragraph 

“SETUP MENU” to 

setup  the  master.  All  slaves  must  be  set  to  SLAVE-mode.  You  can  put  as  many  slaves  as  you  like  on 
condition that the overall power consumption on the power line stays under 10A (2300W). 

IMPORTANT: make sure that no DMX-controller is connected, this will result in unexpected behavior! 

 

 

 

Electrical installation for two or more units in DMX-mode: 

  The  DMX-protocol  is  a  widely  used  high  speed  signal  to  control  intelligent  light  equipment.  You  need  to 

“daisy chain” your DMX controller and all the connected units. 

  Use the supplied DMX input conversion cable (IP-cabling to XLR-male) to connect the first unit in the line 

to the controller.  

  Pin layout XLR-3pin: Pin1 = GND  ~  Pin2 = Negative signal (-)  ~  Pin3 = Positive signal (+) 

  To prevent strange behavior of the  projectors, due  to interferences,  you must use a 

90Ω  to  120Ω  terminator  at  the  end  of  the  chain.  Never  use  Y-splitter  cables,  this 
simply won’t work!  

 

 

Summary of Contents for EXPO CANNON

Page 1: ......

Page 2: ......

Page 3: ...ED refresh rate The lamp behavior can be continuously adjusted from led to halogen Four dimmer curves linear square inverse square S curve In case of DMX failure you can choose between blackout and fr...

Page 4: ...rd Never let the power cord come into contact with other cables This fixture must be earthed in order to comply with safety regulations Don t connect the unit to any dimmer pack Always use an appropri...

Page 5: ...d to browse the different menu options or to exit a menu option button used to go to the next menu option or to decrease a parameter value button used to go to the previous menu option or to increase...

Page 6: ...n openings as this may result in overheating The operator has to make sure that the safety relating and machine technical installations are approved by an expert before using them for the first time T...

Page 7: ...ay Press the ENTER button the values can be changed Use buttons to select the desired DMX512 address The last occupied DMX address is also shown makes it easier to set the address of the next unit in...

Page 8: ...e halogen lamp behavior At the same time the light output will be instantaneous while pushing a flash button on your DMX controller LOCKING Used to lock the setup menu against unwanted altering of the...

Page 9: ...are of this unit can be upgraded using a special upgrade tool with Windows software separately available from Briteq Each time the projector is switched on the display shows UPDATE Wait while this mes...

Page 10: ...ller Since each unit has its own DMX address you can control them individually Remember that each unit uses 1 or 2 DMX channels depending on the DMX mode you have selected in the menu See the differen...

Page 11: ...manufacturer Mains Input AC 110V 240V 50 60Hz Power consumption 380 Watt max Power Factor 94 Fuse 250V T4A 20mm glass DMX connections 3pin XLR male female DMX channels used 1 2 channels Lamp 37pcs CRE...

Page 12: ......

Reviews: