MAINTENANCE 

  Make sure the area below the installation place is free from unwanted persons during servicing. 

  Switch off the unit, unplug the mains cable and wait until the unit has been cooled down. 

During inspection the following points should be checked: 

  All  screws  used  for  installing  the  device  and  any  of  its  parts  should  be  tightly  fastened  and  may  not  be 

corroded. 

  Housings,  fixations  and  installations  spots  (ceiling,  truss,  suspensions)  should  be  totally  free  from  any 

deformation. 

  When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced. 

  The  mains  cables  must  be  in  impeccable  condition  and  should  be  replaced  immediately  when  even  a 

small problem is detected. 

  In order  to  protect  the  device  from  overheat the  cooling  fans  (if  any)  and  ventilation  openings  should  be 

cleaned monthly. 

  The interior of the device should be cleaned annually using a vacuum cleaner or air-jet. 

  The  cleaning  of  internal  and  external  optical  lenses  and/or  mirrors  must  be  carried  out  periodically  to 

optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp, 
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. 

  Clean with a soft cloth using normal glass cleaning products. 

  Always dry the parts carefully. 

Attention: We strongly recommend internal cleaning to be carried out by qualified personnel! 
 

SPECIFICATIONS 

This unit is radio-interference suppressed. This product meets the requirements of the current European and 
national guidelines. Conformity has been established and the relevant statements and documents have been 
deposited by the manufacturer. 

Mains Input: 

AC 100V - 240V, 50/60Hz  

Power consumption:

 

190 Watt max. 

Fuse: 

250V T6,3A (20mm glass) 

Sound Control: 

Internal microphone 

DMX connections: 

3pin XLR male / female

 

 

DMX channels used:

 

5 modes (4, 7, 13, 43, 48CH) 

Lamp:

 

36x  3W WW  (2700 

– 3000K) CREE  leds  –  144x 0,5W SMD 

 

RGB leds 

Size:

 

50x50x8,4cm 

Weight:

 

8,5 kg 

 

The information might be modified without prior notice 

You can download the latest version of this user manual on our website: www.briteq-lighting.com 

 

Summary of Contents for BT-GLOWPANEL

Page 1: ......

Page 2: ......

Page 3: ...erful ever changing light shows Silent operation thanks to natural convection The internal shows work in standalone master slave or can be selected by DMX static colors fading colors different static...

Page 4: ...must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard Never let the power cord come into contact with other cables This fixture must be earth...

Page 5: ...cator yellow LED lits when no DMX signal is present and the fixture is in stand alone mode or when one or more fixtures are connected as slave s 3 MENU used to browse the different options of the setu...

Page 6: ...tup 19 CARRYING HANDLE on the top of the panel there is a folding carrying handle to easily transport the fixture or insert remove it from its flight case 20 Inner thread M8 for use with eye bolts or...

Page 7: ...ENGLISH OPERATION MANUAL BRITEQ 5 23 BT GLOWPANEL...

Page 8: ...ENGLISH OPERATION MANUAL BRITEQ 6 23 BT GLOWPANEL...

Page 9: ...trobe programs letters numbers RGB panel dimming 13CH pixel dimming strobe programs letters numbers speed RGB panel dimming 43CH individual pixel dimming programs letters numbers individual panel RGB...

Page 10: ...to select the desired mode Yes white pixels will work if no DMX signal is present No white pixels will not work if no DMX signal is present Press the ENTER button to select the desired value The sele...

Page 11: ...of this unit can be upgraded using the Briteq Firmware Updater order code 4319 with Windows software More information about this can be found in the user manual of the Firmware Updater and or our webs...

Page 12: ...to control the projectors by any DMX controller Connect the projectors as shown in the drawing below First put the projectors in the desired DMX mode see the different DMX charts and choose the one th...

Page 13: ...due to interferences you must use a 90 to 120 terminator at the end of the chain Never use Y splitter cables this simply won t work Make sure that all units are connected to the mains Each light effec...

Page 14: ...16 136 143 Program 17 144 151 Program 18 152 159 Program 19 160 167 Program 20 168 175 Program 21 176 183 Program 22 184 191 Program 23 192 199 Program 24 200 207 Program 25 208 215 Program 26 216 223...

Page 15: ...129 Letter L 130 138 Letter M 139 147 Letter N 148 156 Letter O 157 165 Letter P 166 174 Letter Q 175 183 Letter R 184 192 Letter S 193 201 Letter T 202 210 Letter U 211 219 Letter V 220 228 Letter W...

Page 16: ...000 044 Blackout 045 067 White Pixels full on 068 247 Blackout 248 255 Sound activated show Channel 7 068 to 127 8 000 007 Blackout 008 015 Program 1 016 023 Program 2 024 031 Program 3 032 039 Progra...

Page 17: ...umber 4 116 135 Number 5 136 155 Number 6 156 175 Number 7 176 195 Number 8 196 215 Number 9 216 235 Count from 0 to 9 slow fast 236 255 Count from 9 to 0 slow fast Channel 7 188 to 247 8 000 021 Blac...

Page 18: ...00 255 Green color dimmer 0 100 13 000 255 Blue color dimmer 0 100 43CH Mode DMX Channel DMX value function remarks 1 000 255 Pixel 1 dimmer 0 100 2 000 255 Pixel 2 dimmer 0 100 3 000 255 Pixel 3 dimm...

Page 19: ...55 Pixel 30 dimmer 0 100 31 000 255 Pixel 31 dimmer 0 100 32 000 255 Pixel 32 dimmer 0 100 33 000 255 Pixel 33 dimmer 0 100 34 000 255 Pixel 34 dimmer 0 100 35 000 255 Pixel 35 dimmer 0 100 36 000 255...

Page 20: ...255 Program 1 30 Random Channel 37 128 to 187 38 000 015 Blackout 016 035 Number 0 036 055 Number 1 056 075 Number 2 076 095 Number 3 096 115 Number 4 116 135 Number 5 136 155 Number 6 156 175 Number...

Page 21: ...trobe Slow Fast 132 139 Full on 140 181 Ramp up effect slow fast 182 231 Ramp down effect slow fast 232 239 Full on 240 247 Strobe Sound triggered 248 255 Full on 41 000 255 Red color dimmer 0 100 42...

Page 22: ...6 dimmer 0 100 27 000 255 Pixel 27 dimmer 0 100 28 000 255 Pixel 28 dimmer 0 100 29 000 255 Pixel 29 dimmer 0 100 30 000 255 Pixel 30 dimmer 0 100 31 000 255 Pixel 31 dimmer 0 100 32 000 255 Pixel 32...

Page 23: ...ernal and external optical lenses and or mirrors must be carried out periodically to optimize light output Cleaning frequency depends on the environment in which the fixture operates damp smoky or par...

Page 24: ...ENGLISH OPERATION MANUAL BRITEQ 22 23 BT GLOWPANEL DIMENSIONS...

Page 25: ......

Page 26: ......

Page 27: ......

Page 28: ......

Reviews: