![Briteq BT-COLORAY MULTI Operation Manual Download Page 13](http://html1.mh-extra.com/html/briteq/bt-coloray-multi/bt-coloray-multi_operation-manual_2814322013.webp)
ENGLISH
OPERATION MANUAL
BRITEQ
®
11/12
BT-COLORAY MULTI
06CH channel DMX-Mode: RGBW + MASTER DIM + STROBE
Channel:
Value:
Function:
Remarks
1
000-255
Red (0-100%)
2
000-255
Green (0-100%)
3
000-255
Blue (0-100%)
4
000-255
White (0-100%)
5
000-255
Master dimmer (0-100%)
6
000-004
ON (no strobe)
005-255
Strobe
Increasing speed: 005=slow ~ 255=fast
07CH RGBW+D+S+DIMSPEED The 4 colors can be set separately, with combined strobe + master
dimmer.
Channel:
Value:
Function:
Remarks
1
000-255
Red (0-100%)
2
000-255
Green (0-100%)
3
000-255
Blue (0-100%)
4
000-255
White (0-100%)
5
000-255
Master dimmer (0-100%)
6
000-004
ON (no strobe)
005-255
Strobe
Increasing speed: 005=slow ~ 255=fast
7
000-255
DIM SPEED
Increasing dimming speed : 000=fast ~
255=slow
MAINTENANCE
•
Make sure the area below the installation place is free from unwanted persons during servicing.
•
Switch off the unit, unplug the mains cable and wait until the unit has been cooled down.
During inspection the following points should be checked:
•
All screws used for installing the device and any of its parts should be tightly fastened and may not be
corroded.
•
Housings, fixations and installations spots (ceiling, truss, suspensions) should be totally free from any
deformation.
•
When an optical lens is visibly damaged due to cracks or deep scratches, it must be replaced.
•
The mains cables must be in impeccable condition and should be replaced immediately when even a
small problem is detected.
•
In order to protect the device from overheat the cooling fans (if any) and ventilation openings should be
cleaned monthly.
•
The interior of the device should be cleaned annually using a vacuum cleaner or air-jet.
•
The cleaning of internal and external optical lenses and/or mirrors must be carried out periodically to
optimize light output. Cleaning frequency depends on the environment in which the fixture operates: damp,
smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics.
•
Clean with a soft cloth using normal glass cleaning products.
•
Always dry the parts carefully.
Attention: We strongly recommend internal cleaning to be carried out by qualified personnel!