background image

Operating Manual 400-115-050-EFS

4

ENG

LISH

Quick reference to controls

On/Standby switch

1

Day button

Up/Down buttons

2

Program button

Mode selection /program exit

Preset temperature buttons

Backlight button

2

Program clear button

Hour button

Minutes button

1

Place on Standby to cut power to the heater (e.g., in the summer). This will not affect the time and temperature settings.

2

When the backlight button or either of the 

 (Up/Down) buttons is pressed, the display illuminates for 12 seconds.

TEST light /button for ground 
fault protection (see page 18)

Summary of Contents for TH115-AF-AG-10

Page 1: ...Owner s Guide Guide du propri taire Gu a para el usuario TH115 AF GB 10 Programmable thermostat Thermostat programmable Termostato programable...

Page 2: ...Read and save these instructions Veuillez lire le mode d emploi et le conserver en lieu s r Estas instrucciones deben leerse y conservarse...

Page 3: ...itches 9 Setup Clock and day 10 Daylight Saving Time 11 Floor temperature limits 12 Preset temperatures 13 Default schedule Energy Star settings 14 Modifying the schedule 15 Operation Running the sche...

Page 4: ...install the thermostat in an area where it can be exposed to water or rain To prevent severe shock or electrocution always turn the power OFF at the service panel before working with wiring Install t...

Page 5: ...Two 2 mounting screws Four 4 solderless connectors for copper wires One 1 floor sensor One 1 flat tip screwdriver About your thermostat A mode controls the ambient air temperature F mode controls the...

Page 6: ...perature buttons Backlight button2 Program clear button Hour button Minutes button 1 Place on Standby to cut power to the heater e g in the summer This will not affect the time and temperature setting...

Page 7: ...yed Temperature control mode see page 3 Ground fault indicator see page 18 Day The thermostat normally displays the actual measured temperature To view the setpoint press either of the buttons once Th...

Page 8: ...r supply and to the load see page 7 q Connect the floor sensor see page 8 r If you wish to connect a remote control device see page 8 s Install the wallplate to the electrical box using the provided s...

Page 9: ...OTE Connect the wires using the provided solderless connectors for copper wires Wiring diagram White 120 V Load Power supply Red Black Red Red Black Black Red Black 240 V Load Power supply Red Black R...

Page 10: ...g wires for best temperature control Do NOT staple the sensor head the plastic end to the floor Doing so might damage the sensor Any damages might not be noticeable during testing but can become appar...

Page 11: ...er to obtain the desired temperature by the set time The thermostat re assesses the start time daily based on the previous day s results Enable Disable 3 Temperature control mode2 2 See temperature co...

Page 12: ...115 050 EFS 10 ENGLISH To set the clock and the day n Press the Hour button to set the hour o Press the Min button to set the minutes p Press the Day button to set the day q Press the Mode Ret button...

Page 13: ...he date n Press the Day button 3 seconds until DLS appears on the screen o Press either of the buttons to toggle between On enabled and Off disabled p Press the Day button briefly The year setting is...

Page 14: ...t To modify these limits proceed as follows n Switch the thermostat to Standby o Press and hold the button p Switch the thermostat back to On q Release the button when the minimum temperature limit FL...

Page 15: ...ent setpoint and its icon will appear on the screen To modify a preset temperature n Set the desired temperature using the buttons o Press and hold the appropriate preset temperature button until its...

Page 16: ...2 periods set periods 1 and 4 or periods 2 and 3 The Early Start func tion see page 9 will not work if you set periods 1 and 2 or periods 3 and 4 You can have a different program for each day of the...

Page 17: ...our and Min to set the start time of the selected period or press Clear if you want to skip the period is displayed q Press Pgm to select another period or press Day to select another day Then repeat...

Page 18: ...e Ret until is dis played Temporary override of schedule If you modify the setpoint temperature by pressing the or button when the thermostat is in Automatic Mode the new temperature will be used unti...

Page 19: ...mode press Mode Ret to display on the screen Set the temperature using the or button In this mode the thermostat uses the vacation preset temperature see page 13 To place the thermostat in vacation m...

Page 20: ...s body to reach the ground For example a defective floor heating mat can cause a ground fault A ground fault protection thermostat does not protect against circuit overloads short circuits or electri...

Page 21: ...lation and if necessary replace the thermostat If the TEST light comes on continue the test p Switch the thermostat to Standby then back to On If the TEST light goes off the test has passed Set the th...

Page 22: ...The measured temperature is below the thermostat s display range Heating is activated The measured temperature is above the thermostat s display range Heating is deactivated Verify the thermostat conn...

Page 23: ...ing cycle length 15 minutes Data protection In the event of a power failure most settings are saved Only the time and Daylight Saving Time must be set if the power failure lasts more than 6 hours The...

Page 24: ...Operating Manual 400 115 050 EFS 22 ENGLISH Customer Assistance...

Page 25: ...TH115 AF GB 10 23 ENGLISH Warranty...

Page 26: ...Operating Manual 400 115 050 EFS 24 ENGLISH...

Page 27: ......

Page 28: ......

Reviews: