TB4000 Bulb and Capillary  

Temperature Controller 

Sensor Location: 

Position and attach bulb temperature sensor directly on top of the heater or 
touching the edge of the heater while also contacting the surface being heated. 
Temperature sensing bulb must be in close proximity of heater for accurate 
temperature control and to prevent over-heating. Use appropriate  
temperature- rated adhesive tape to attach bulb or for large tanks and vessels 
use a bulb bracket (available from BriskHeat

®

)

If you have questions 

concerning your application please contact your local distributor or BriskHeat

®

 

at 1-800-848-7673 (U.S. & Canada),  1-614-294-3376 (World wide), or 
[email protected]

 

Electrical Connections:

 

Holes for conduit and fittings may be made using a standard hole saw. Take 
care to avoid damaging components when making holes.   

 

Heater Connections:

 

Connect heater wires to the proper terminals. Proper over-current protection 
should be located in the supply lines. Contact your local distributor or 
BriskHeat

®

 at 1-800-848-7673 (U.S. & Canada), 1-614-294-3376 (World wide), 

or [email protected] for additional assistance. 

 

Alarm Connections (If applicable):

 

On all models with the alarm feature, the loose wire must be connected to the 
proper terminal on the terminal block for the light to function in the proper 
manner.  Refer to the electrical diagram on the next page. 
 
On some models, a transformer may be supplied or retrofitted to avoid running 
a second alarm supply.  Consult the factory for assistance with your specific 
installation/application. 

 

DO NOT BEND, KINK, OR CRIMP THE BULB 
AND CAPILLARY - This will cause loss of  
calibration and might render the controller  
inoperative.  All warranties will be void if bulb or 
capillary is damaged. 

INSTALLATION INSTRUCTIONS 

Mounting: 

The enclosure should be mounted in a suitable location.  Be sure that the bulb 
will reach the desired sensing area.  The mounting holes can be turned to aid 
in installation if necessary. 

Summary of Contents for TB4000

Page 1: ...ervicing these heating tapes Failure to understand how to safely operate these heaters could result in an accident causing serious injury or death These heaters should only be operated by qualified personnel TB4000 Temperature Controller Instruction Manual ...

Page 2: ...equiring automatic control SAVE THESE INSTRUCTIONS Additional copies of this manual are available upon request SAFETY ALERT SYMBOL The symbol above is used to call your attention to instructions concerning your personal safety It points out important safety precautions It means ATTENTION Become Alert Your Personal Safety is involved Read the message that follows and be alert to the possibility of ...

Page 3: ...ions Failure to observe these warnings may result in electric shock risk of fire and personal injury End User Must Comply to the Following Only qualified personnel are allowed to connect electrical wiring All electrical wiring must follow local electrical codes and highly recommend following NEC Article 427 Final installation wiring is to be inspected by the authority who has jurisdiction in the a...

Page 4: ... heater wires to the proper terminals Proper over current protection should be located in the supply lines Contact your local distributor or BriskHeat at 1 800 848 7673 U S Canada 1 614 294 3376 World wide or bhtsales1 briskheat com for additional assistance Alarm Connections If applicable On all models with the alarm feature the loose wire must be connected to the proper terminal on the terminal ...

Page 5: ...BriskHeat Corporation All rights reserved 5 TB4000 Bulb and Capillary Temperature Controller Alarm Connection Wiring Diagram ...

Page 6: ...peration The alarm may be used as a high or low alarm depending on the connections used In the high temperature alarm mode the alarm light illuminates and the external device if applicable operates when the sensed temperature is above the alarm point NOTE To verify alarm operation turn the alarm point dial to a setting lower than the sensed temperature Validate the alarm light illuminates Return d...

Page 7: ...r source and assure correct voltage is present Check to see if there is a resistance reading not an open circuit in heater using an ohm meter Heater does not turn off Check set point Ensure correct bulb placement Check bulb and capillary for any holes or kinks Heater will not reach desired temperature Check set point Ensure correct bulb placement Power source circuit breaker trips Validate that th...

Page 8: ...ration All rights reserved 8 TB4000 Bulb and Capillary Temperature Controller 1055 Gibbard Ave Columbus OH 43201 Toll Free 800 848 7673 Phone 614 294 3376 Fax 614 294 3807 Email bhtsales1 briskheat com PN 40479 Rev D ...

Reviews: