INSTALLATION / OPERATING INSTRUCTIONS 

Requirements: 



Electrical terminations must be completed by qualified persons. 



No special tools or protective equipment is needed to handle this product (specific applications or 
surfaces may require protective equipment). 



The power supply frequency must be /-10% of the value specified on the product label. 

Set Up 

1. 

Inspect the temperature controller and heater for damage prior to each use (see the Inspection 
section on Page 9).  

2. 

Position the temperature controller on a clean, dry, and flat surface. Avoid potential damage from 
the heater or other heat sources. Ensure the temperature sensor can safely reach the object being 
monitored.  

3. 

Connect the input power supply cord to the controller’s input power receptacle (see Figure 1).  

4. 

Connect the temperature controller to an appropriately rated electrical source. For 240V models 
without a pre-terminated input power cord, installation of an appropriately rated plug is required.  

5. 

Adjust temperature controller’s set-point and parameters as necessary (see PARAMETERS 
section on Page 7). 

6. 

Position the tip of the temperature sensor so that the critical temperature region of the component 
being heated can be monitored. Secure the temperature sensor using appropriately rated adhesive 
tape or tie down (not provided).   

7. 

Mount the heater to the component being heated.  

8. 

Connect the heater’s power cord to the temperature controller’s heater power receptacle (see 
Figure 1). For 240V models with heater power connector, see heater power connector installation 
procedure on Page 8.  

NOTE: When power is supplied to the temperature controller, the components become energized and 

the heater may begin heating if plugged in. Do not connect the heater to the controller until 
the heater has been properly installed and the controller parameters have been set.       

Figure 1 

© BriskHeat

®

 Corporation.  All rights reserved.  

 

SDCE Digital Benchtop Temperature Controller 

 

 

 

 

Button Functions: 

Up arrow - Scroll Up  

Allows the operator to adjust temperature setting and parameter options (See PARAMETERS 
section for more information). 

Down arrow - Scroll Down and Quick Temperature Set Point Access  

Allows quick access to modify controller set point value when pushed once. Allows the operator to 
adjust temperature setting and parameter options (See PARAMETERS section on Page 7 for more 
information). 

U button - Standby Mode  

Press to toggle the temperature controller in/out of standby mode. While in standby mode, the 
heater will de-energized and all heating and temperature monitoring operations cease until taken 
out of standby mode.  

P button - Programming Mode  

Grants access to program the temperature controllers parameters (See PARAMETERS section on 
Page 7 for more information). 

Quick Start Operation: 

1. 

Default temperature set-point is 0, default unit is °C.  

2. 

Press Down Arrow to access / change the temperature set-point parameter.  

3. 

Press Up/Down arrows to adjust the temperature to desired set-point.  

4. 

Press and Hold the P button exit the temperature set-point parameter.  

To Change Temperature Units (

°

C or 

°

F) or Element Type: 

1. 

Press and hold the P button for approximately 5 seconds.  

2. 

Press the Up or Down arrow until SEN displays on the controller. 

3. 

Press the P button to select. The instrument will alternatively visualize the parameter’s code and 
its current value. 

4. 

Press the UP and DOWN buttons until the desired parameter is displayed. See PARAMETERS 
section on Page 7 for more information. 

5. 

Press the P button to save the desired value. The display will return to visualize only the code of 
the selected parameter.  

6. 

Exit the programming mode by pressing and holding the UP arrow for approximately five seconds 
or wait 30 seconds for the controller to automatically exit the programming mode. When the 
temperature displays, the controller is no longer in the programming mode. 

Figure 2 

Summary of Contents for SDCE

Page 1: ...perating Instructions 5 Parameters 7 240V Heater Power Connector Installation 8 Alarm Settings 9 Maintenance Instructions 10 Emergency Procedures 10 Troubleshooting Guide 11 Warranty Information 12 IN...

Page 2: ...nces should condensations rain snow or water be allowed to come in contact with the box or the controller while in storage Failure to observe these warnings may result in personal injury or damage to...

Page 3: ...rly installed and the controller parameters have been set Figure 1 BriskHeat Corporation All rights reserved 6 SDCE Digital Benchtop Temperature Controller Button Functions Up arrow Scroll Up Allows t...

Page 4: ...to modify using the steps above 7 To exit the programming mode press and hold the UP button for approximately five seconds or wait 30 seconds for the controller to automatically exit the programming m...

Page 5: ...is manually reset To manually reset the alarm press and hold both the U and P buttons for 5 seconds AL A Acknowledgeable alarm While the temperature is extends past the High Limit Alarm the alarm can...

Page 6: ...current temperature Controller Heats Too Much Before Turning Off Adjust the hysteresis Enter the Programming Mode and Select d1 Change the value The lower the value the smaller mount of temperature o...

Page 7: ...0 Configuraci n de la alarma 21 Instrucciones de mantenimiento 22 Procedimientos de emergencia 22 Gu a para la resoluci n de problemas 23 Informaci n de la garant a 24 INTRODUCCI N El controlador disc...

Page 8: ...la caja ni el controlador deben estar en contacto con condensaci n lluvia nieve o agua bajo ninguna circunstancia mientras se encuentren guardados No respetar estas advertencias puede originar lesion...

Page 9: ...entador al controlador hasta haber instalado correctamente el calentador y haber configurado los par metros del controlador Figure 1 BriskHeat Corporation Todos los derechos reservados 18 Controlador...

Page 10: ...o el bot n ARRIBA durante unos cinco segundos o espere 30 segundos hasta que el controlador salga del modo de programaci n de forma autom tica Cuando se muestra la temperatura el controlador ya no est...

Page 11: ...se vuelva a restablecer manualmente Para restablecer la alarma de forma manual mantenga pulsados los botones U y P durante cinco segundos AL A Alarma de confirmaci n mientras la temperatura llega a e...

Page 12: ...mayor que la temperatura actual El controlador se calienta demasiado antes de apagarse Ajuste la hist resis Acceda al modo de programaci n y seleccione d1 Modifique el valor Cuanto m s bajo sea el va...

Page 13: ...eur 32 Param tres d alarme 33 Consignes d entretien 34 Proc dures d urgence 34 Guide de d pannage 35 Renseignements sur la garantie 36 INTRODUCTION Le r gulateur num rique de temp rature SDCE de table...

Page 14: ...t g e Aucune condensation pluie neige ou eau ne doit entrer en contact avec la bo te ou le r gulateur pendant l entreposage Le non respect de ces avertissements pourrait entra ner des blessures ou end...

Page 15: ...uffeur n a pas t correctement install et que les param tres du r gulateur n ont pas t r gl s Figure 1 BriskHeat Corporation Tous droits r serv s 30 Contr leur de Temp rature SDCE Digital Benchtop Fonc...

Page 16: ...rogrammation maintenez le bouton HAUT enfonc pendant environ cinq secondes ou attendez 30 secondes pour que le r gulateur quitte automatiquement le mode de programmation Lorsque la temp rature s affic...

Page 17: ...initialiser l alarme manuellement maintenez les boutons U et P enfonc s pendant 5 secondes AL A Alarme pouvant faire l objet d un accus de r ception Lorsque la temp rature d passe la valeur du param...

Page 18: ...r gl une temp rature sup rieure la temp rature actuelle Le r gulateur chauffe trop avant de s arr ter Ajustez l hyst r sis Acc dez au mode de programmation et s lectionnez d1 Modifiez la valeur Moins...

Page 19: ...stallation des 240V Stromanschlusses des Heizger ts 44 Alarmeinstellungen 45 Wartungsanweisungen 46 Notfallma nahmen 46 Fehlersuchanleitung 47 Garantieinformationen 48 EINF HRUNG Der BriskHeat digital...

Page 20: ...trockenen gesch tzten Ort in einem geschlossenen Raum gelagert werden Der Karton bzw Regler darf w hrend der Lagerung unter keinen Umst nden mit Kondensation Regen Schnee oder Wasser in Ber hrung kom...

Page 21: ...meter eingestellt wurden Figure 1 BriskHeat Corporation Alle Rechte vorbehalten 42 SDCE Digitaler Benchtop Temperaturregler Tastenfunktionen Pfeil nach oben nach oben scrollen Erlaubt dem Bediener die...

Page 22: ...Zum Verlassen des Programmiermodus die Taste nach OBEN dr cken und etwa f nf Sekunden gedr ckt halten oder 30 Sekunden warten bis der Regler den Programmiermodus automatisch verl sst Wenn die Tempera...

Page 23: ...llen R ckstellung aktiv Zur manuellen R cksetzung des Alarms die Tasten U und P 5 dr cken und 5 Sekunden gedr ckt halten AL A quittierbarer Alarm Wenn die Temperatur ber die Obere Alarmgrenze ansteigt...

Page 24: ...icht besch digt ist berpr fen ob der Regler Sollwert h her ist als die aktuelle Temperatur Der Regler wird zu hei vor dem Abschalten Hysterese anpassen Programmiermodus eingeben und d1 w hlen Den Wert...

Page 25: ...tore a 240V 56 Impostazioni allarme 57 Istruzioni per la manutenzione 58 Procedure di emergenza 58 Guida alla risoluzione dei problemi 59 Informazioni sulla garanzia 60 INTRODUZIONE Il regolatore di t...

Page 26: ...rvata al coperto in un area asciutta e protetta In nessun caso condensa pioggia neve o acqua devono poter venire a contatto con la cassetta o con il regolatore di temperatura durante la conservazione...

Page 27: ...i parametri del regolatore sono stati impostati Figure 1 BriskHeat Corporation Tutti i diritti riservati 54 Benchmark Digitale SDCE Regolatore di Temperatura Funzioni dei pulsanti Freccia su Scorri v...

Page 28: ...nere premuto il pulsante SU per circa cinque secondi oppure attendere 30 secondi affinch il regolatore non uscir automaticamente dalla modalit di programmazione Quando la temperatura viene visualizzat...

Page 29: ...llarme resta bloccata fino a quando l allarme non viene ripristinato manualmente Per ripristinare manualmente l allarme tenere premuti i pulsanti U e P per 5 secondi Al A Allarme riscontrabile Quando...

Page 30: ...Il regolatore riscalda troppo prima di spegnersi Regolare l isteresi Accedere alla Modalit Programmazione e selezionare d1 Modificare il valore Pi il valore basso minore il Messaggi di errore Nel caso...

Reviews: