Trouble Shooting: Status Register Definitions
Status Code:
_ _ _ _
Last Digit of Status Code
Third Digit of Status Code
Second Digit of Status Code
First Digit of Status Code
Value
First Digit
of Status Code
Second Digit
of Status Code
Third Digit of
Status Code
Last Digit
of Status Code
0 or
BLANK
No Value
No Value
No Value
Zone is Disabled
1
Blink Id
Status Network Comm Bad
Status Rtd
Open
Status Ok
2
Adaptive Tuning
Enabled
Status Heater Config Comm Bad
N/A
Status High
3
Adaptive Tuning
Enabled, Blink Id
Status Heater Config Comm Bad,
Status Network Comm Bad
N/A
Status High,
Status Ok
4
Start Jacket Test
Status Line Ctrl Comm Bad
N/A
Status Low
5
Start Jacket Test,
Blink Id
Status Line Ctrl Comm Bad,
Status Network Comm Bad
N/A
Status Low,
Status Ok
6
Start Jacket Test,
Adaptive Tuning
Enabled,
Status Line Ctrl Comm Bad,
Status Heater Config Comm Bad,
N/A
Status Low,
Status High,
7
Start Jacket Test,
Adaptive Tuning
Enabled, Blink Id
Status Line Ctrl Comm Bad,
Status Heater Config Comm Bad,
Status Network Comm Bad
N/A
Status Low,
Status High,
Status Ok
8
Enable Heater Control
Calibrate Rtd Circuit
Status Triac
Driver Bad
Status Rtd Short
9
Enable Heater Control,
Blink Id
Calibrate Rtd Circuit, Status
Network Comm Bad
Status Triac
Driver Bad,
Status Rtd
Open
Status Rtd Short,
Status Ok
A
Enable Heater Control,
Adaptive Tuning
Enabled,
Calibrate Rtd Circuit, Status
Heater Config Comm Bad,
N/A
Status Rtd Short,
Status High,
B
Enable Heater Control,
Adaptive Tuning
Enabled, Blink Id
Calibrate Rtd Circuit,
Status Heater Config Comm Bad,
Status Network Comm Bad
N/A
Status Rtd Short,
Status High,
Status Ok
C
Enable Heater Control,
Start Jacket Test,
Calibrate Rtd Circuit,
Status Line Ctrl Comm Bad,
N/A
Status Rtd Short,
Status Low,
D
Enable Heater Control,
Start Jacket Test,
Blink Id
Calibrate Rtd Circuit,
Status Line Ctrl Comm Bad,
Status Network Comm Bad
N/A
Status Rtd Short,
Status Low,
Status Ok
E
Enable Heater Control,
Start Jacket Test,
Adaptive Tuning
Enabled,
Calibrate Rtd Circuit,
Status Line Ctrl Comm Bad,
Status Heater Config Comm Bad,
N/A
Status Rtd Short,
Status Low,
Status High,
F
Enable Heater Control,
Start Jacket Test,
Adaptive Tuning
Enabled, Blink Id
Calibrate Rtd Circuit,
Status Line Ctrl Comm Bad,
Status Heater Config Comm Bad,
Status Network Comm Bad
N/A
Status Rtd Short,
Status Low,
Status High,
Status Ok