Renovent HR Medium/Large 2nd edition Augustus 2007
17
Putting into operation
Chapter 6
6.1 Switching the appliance on and off
There are two methods to switch the appliance on or off.
7KURXJKVRIWZDUHWKHDSSOLDQFHUHPDLQVFRQQHFWHGWRWKH
mains, when switching off bu software only the fans are
stopped.
5HPRYLQJWKHPDLQVSOXJRULQVHUWLQJLWLQWRWKHZDOOVRFNHW
the voltage is taken from the appliance.
Switching on
• Mains power: connect the mains
plug to the electric installation
7KURXJK VRIWZDUH VLPXOWDQH
-
ously press keys “
OK
” and “
+
” to
switch on the appliance through
software
(Only possible after the appliance
has been switched off through
software.)
7KH¿UVWGLJLWRQWKHGLVSOD\LQGLFD
-
tes the position of the 3-way switch.
Switching off
7KURXJK VRIWZDUH VLPXOWDQHRXVO\
press keys “
OK
” and “
-
” to switch
on the appliance through software.
The text OFF appears on the dis-
play.
• Mains power: pull the mains plug
from the mains to take the voltage
from the appliance.
127(
When working on the appliance, always take the voltage
IURPWKHDSSOLDQFHE\¿UVWVZLWFKLQJLWRIIWKURXJKVRIWZDUH
and subsequently pulling the mains plug.
6.2 Setting the air quantity
The air quantity of the Renovent HR Medium/Large for settings
1, 2 and 2 have been adjusted in the factory at 100, /150/200
and 225/300 m
3
/h. The performance of the Renovent depends
RQWKHTXDOLW\RIWKHGXFWV\VWHPDVZHOODVRQWKH¿OWHUUHVL
-
stance.
Important:
Setting 1: must always be lower than setting 2.
6HWWLQJPXVWDOZD\VEHORZHUWKDQVHWWLQJ
Setting 3: adjustable between 50 and 300/400 m
3
K
If these conditions are not complied with, the air quantity of the
higher setting will automatically be adjusted.
7KHDLUTXDQWLWLHVFDQEHPRGL¿HGDVIROORZVDVDQH[DPSOH
here the air quantity for setting 3 will be changed from 300 to
280 m
3
/h):
1. Press key “
F
” during 3 seconds to
call up the settings menu.
2. Use key “
+
” to select the desired
parameter (U1 = setting 1: 1, U2 =
VHWWLQJ8 VHWWLQJ88
and U8 only apply when a bypass
unit is used).
3. Press key “
OK
” during 1 second to
read the selected parameter value.
4. The keys “
+
” or “
-
” can be used to
modify the selected parameter va-
lue.
>3s
>3s
>3s
5383-0