INTRODUCTION 

This fire is CE approved to the European 
Standard EN 509 and is intended for decorative 
purposes.  

The fire must be installed and serviced by a 
qualified CORGI registered installation engineer 
in accordance with National and Local 
Regulations. 

Servicing should be carried out at least 
annually, but depending upon site conditions 
more frequently. 

RELEVANT STANDARDS 

Building Regulations Part J 
BS 1289 : Part 1 : Pre-cast concrete flue blocks 
BS 5440 : Part 1 : Flues 
BS 5440 : Part 2 : Air Supply 
BS 5871 : Part 1 : Installation of gas appliances 
BS 6891 : Gas Installation 

Before installation ensure that the local 
distribution conditions (identification of the type 
of gas and pressure) and the adjustment of the 
appliance are compatible. 

The Gas Category of this fire is 

II

2H3P

 and is 

available set for either Natural Gas (G20) or LPG 
Propane (G31) check the Gas Type on the burner 
data badge is correctly marked for your gas 
supply. A conversion kit is available separately 
direct from Brilliant or your nearest dealer. 

The fire is fitted with an Oxygen Depletion 
Sensor (ODS) which continuously monitors the 
atmosphere in the room turning off the gas 
supply to the fire if combustion products are 
detected. The ODS must not be adjusted or put 
out of operation and only original 
manufacturer’s replacement parts can be used. 

 

 

 

 

 

 

TECHNICAL INFORMATION 

NATURAL GAS (G20) 

 

 

16/18 Standard  16/18 High 

Heat Input Max (gross): 

7.0 kW 

  9.0kW 

Heat Input Min (gross):  

4.1 kW 

  4.4kW 

Inlet Pressure: 

 

20 mbar 

  20mbar 

Injector size (Manual):   

504   

  704 

Injector size (Remote):  

494   

  NA* 

Number of Injectors:    

 

  1 

Gas Connection Size:   

8mm   

  8mm 

Weight: 

 

       See Packaging 

LPG PROPANE (G31) 

 

16/18 Standard 

Heat Input Max (gross): 

6.3 kW 

Heat Input Min (gross):  

5.3 kW 

Inlet Pressure:  

 

37 mbar    

Injector size:  

 

194 

Number of Injectors:    

Gas Connection Size:    

8mm 

Weight: 

 

See Packaging

 

NOTE: Both the 16” and 18” versions use the 
same burner. On the 18 “ version the ceramic 
fuel effect pieces are wider and will fill the extra 
space. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INSTALLATION INSTRUCTIONS - ALL VERSIONS 

* Not Available on this model 

Summary of Contents for ROMANCE

Page 1: ...liant FIRE range USER INSTALLATION AND SERVICING INSTRUCTIONS Please read these instructions before installation and use Keep this booklet handy for future reference RO RO RO RO ROMANCE the brilliant...

Page 2: ...2 CONTENTS 3 8 10 11 12 13 USER S INSTRUCTIONS INSTALLER S INSTRUCTIONS ROMANCE PLACEMENT OF CERAMICS PEBBLE AND COAL DRIFTWOOD AND CHARCOAL COMMISIONING AND SERVICING...

Page 3: ...Depress the gas control knob slightly and turn clockwise to the pilot position spark symbol The main burner will go out and the pilot will remain lit and may be left on permanently To turn the pilot...

Page 4: ...eries When replacing the batteries all 6 batteries must be replaced at the same time using new alkaline AA or equivalent batteries DO NOT mix old and new batteries To replace the batteries the holder...

Page 5: ...continuously monitors the atmosphere in the room turning off the gas supply to the fire if combustion products are detected If the fire turns itself off re light the fire following the lighting proced...

Page 6: ...ed installation engineer in accordance with National and Local Regulations Servicing should be carried out at least annually but depending upon site conditions more frequently On all fires the data ba...

Page 7: ...7 Blank...

Page 8: ...or your gas supply A conversion kit is available separately direct from Brilliant or your nearest dealer The fire is fitted with an Oxygen Depletion Sensor ODS which continuously monitors the atmosphe...

Page 9: ...the chimney flue All other openings must be sealed using non combustible materials FLUE The chimney flue must be class 1 and must have a height of at least 3m with an internal diameter of not less th...

Page 10: ...line with the slot in the hearth plate Shape and cut the gas supply pipe and ensuring the gas supply pipe is clean internally connect to the isolating tap Refit the burner and connect the gas supply...

Page 11: ...eeping the Heat Shield Assembly in its correct orientation the following instructions and refer to Figures C 3 and C 4 The Control Knob Heat Shield is only used on Manual burner trays Remove the Knob...

Page 12: ...w of loose pebbles as shown They should not overlap each other and should be as spaced out as possible Alter the angle of the loose pebbles to produce a good flame picture 4 Second Row 5 Pieces 1 Loca...

Page 13: ...refully place the numbered loose driftwood pieces 2 Underbed 1 Locate the base of the front ceramic piece up against the brackets at the front edge either end of the burner It must sit flat on the bur...

Page 14: ...If there is an extractor fan fitted in a nearby room repeat the test with the fan turned on and any interconnecting doors left open Hand over the instructions and explain to the user the operation an...

Page 15: ...15 Blank...

Page 16: ...16 15 11 2010 Brilliant Fires Limited Thwaites Close Blackburn BB1 2QQ England tel 44 0 1254 682384 fax 44 0 1254 672647 www brilliantfires co uk info brilliantfires co uk...

Reviews: