21

No.

Part name

No.

Part name

 1

 Top cover 

 26

 Wiring terminal

 2

 Rear grille

 27

 Intake valve

 3

 Vaporiser

 28

 Pressure gauge

 4

 Insulation plate

 29

 Blue sealing lip 

 5

 PFC coil

 30

 Cover for wiring power supply 

 6

 Pillar

 31

 Watertight box

 7

 Fan motor handle

 32

 Red sealing lip 

 8

 Side grille

 33

 Regulator 

 9

 Fan motor 

 34

 Flow switch

 10

 Base

 35

Copper pipes 

 11

 Lead

 36

 High pressure switch

 12

 Drainage stopper

 37

 Low pressure switch 1

 13

 PC inverter board

 38

 Low pressure switch 2

 14

 Regulator box cover 

 39

 Filter

 16

 Regulator box

 40

 Temperature sensor handle

 17

 Distribution board

 41

 4-way valve 

 18

 Front panel

 42

 Rear panel

 19

 Fan blade

 43

 Electronic expansion valve

 20

 Fan grille

 44

 Ambient temperature sensor handle 

 21

 Tank for liquid

 45

 Discharge water connection nut 

 22

 Compressor 

 46

 Water supply connection nut 

 23

 Titanium exchanger 

 24

 Terminal block

 25

 5-position electric terminal

Summary of Contents for XHPFD 100 E

Page 1: ...INVERTER SWIMMING POOL HEAT PUMP USER MANUAL Illustrative photo i Read the instructions EN VERZE 8 6 2017 REVIZE 3 11 2017...

Page 2: ...ol heat pump for your pool heating it will heat your pool water and keep the constant temperature when ambient temperature at 10 C to 35 C Regulation EU n 517 2014 of 16 04 14 on fluorinated greenhous...

Page 3: ...ump during winter time or when the ambient temperature drops below 0 C or else the Titanium exchanger will be damaged because of being frozen in such case your warranty will be lost WARNING Please alw...

Page 4: ...PH Std Current Input A 3 7 4 6 5 4 Maximum Current A 6 65 Minimum fuse A 18 18 18 Water in out connection mm 50 Fan quantity 1 Ventilation type Horizontal Compressor brand GMCC GMCC GMCC Compressor t...

Page 5: ...nt Input A 7 2 9 11 9 Maximum Current A 11 31 25 32 Minimum fuse A 31 Water in out connection mm 50 Fan quantity 1 2 Ventilation type Horizont ln Compressor brand MITSUBISHI MITSUBISHI PANASONIC Compr...

Page 6: ...s m3 h Voltage 380 V 50 Hz 3 PH 220 240 V 50 Hz 1 PH 380 V 50 Hz 3 PH Std Current Input A 5 1 14 9 6 4 Maximum Current A 15 40 18 Minimum fuse A Water in out connection mm 50 Fan quantity 2 Ventilatio...

Page 7: ...7 2 Dimension XHPFD 100 E XHPFD 160 E...

Page 8: ...ation please consult more instruction from technicians 6 When install a bypass it should be not exceed 30 of nominal flow rate 7 Must make Water level higher than the circulation pump location 8 Below...

Page 9: ...lose the valve direct 2 Make sure that the pump and the water in pipe have been filled with water 3 Start the unit 16 The location of chemical s instruction to your system is also critical to the heat...

Page 10: ...must be running to cause the water to circulate through the heat pump The heat pump will not start up if the water is not circulating After all connections have been made and checked carry out the fo...

Page 11: ...will trigger this time delay and prevent the unit from restarting immediately Additional power interruptions during this delay period do not affect the 3 minute duration of the delay Condensation The...

Page 12: ...6 2 button It will be under function only with other button 6 3 and button Clock unclock the display Hold and for 5 seconds to lock Unlock the display Water temperature setting Press or to set the wa...

Page 13: ...time All error code 6 9 Press first then press to check adjust the User parameter from P1 to P7 Parameter code Condition Range Default Remarks P1 Working mode 0 1 1 1 Heating mode 0 cooling mode P2 Ti...

Page 14: ...will flash When in Full output the lamp of Smart is lighting the lamp of Powerful will be flash 6 12 While you choose the Silent the heat pump will just operate in Medium output and Small output When...

Page 15: ...3 Smart 15 Powerful setT 1 Powerful 7 2 The Cooling operation logic Working status Working mode Water in temperature Heat pump working level 1 Start up of heat pump Smart setT 1 Standby 2 setT 1 a se...

Page 16: ...ve a specialised company change add refrigerant 2 Clean air heat exchanger 3 Replace the filter 4 Check and reconnect the electrical cables from the low pressure switch 5 Replace the low pressure swit...

Page 17: ...circuit breaker if it is connected LED wire controller displays the actual time Heat pump under standby status Startup heat pump to run LED wire controller displays the actual water temperature 1 Wate...

Page 18: ...Heating pipe temperature F Temperature of exhaust gases G Water out temperature H Water in temperature I Display Control J Water flow switch K Defrost switch L Low Pressure switch M High Pressure swit...

Page 19: ...ct A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps I...

Page 20: ...20 11 Exploded view...

Page 21: ...pipes 11 Lead 36 High pressure switch 12 Drainage stopper 37 Low pressure switch 1 13 PC inverter board 38 Low pressure switch 2 14 Regulator box cover 39 Filter 16 Regulator box 40 Temperature senso...

Page 22: ......