Depending on the initial temperature of the water in the swimming pool and the air temperature, 
it may take several days to heat the water to the desired temperature. A good swimming pool 
cover can dramatically reduce the required length of time.

Water Flow Switch:  

It is equipped with a flow switch for protecting the HP unit running with adequate   water flow 
rate .It will turn on when the  pool pump runs and shut it off when the 
pump shuts off. If the pool water level higher than 1 m above or below the heat  
pump’s automatic adjustment knob, your dealer may need to adjust its initial 
startup. 

Time delay 

The heat pump has a built-in 3-minute start-up delay to protect the circuitry and avoid excessive 
contact wear. The unit will restart automatically after this time delay expires. Even a brief 
power interruption will trigger this time delay and prevent the unit from restarting immediately. 
Additional power interruptions during this delay period do not affect the 3-minute duration of 
the delay.

Condensation

The air drawn into the heat pump is strongly cooled by the operation of the heat pump for 
heating the pool water, which may cause condensation on the fins of the evaporator. The 
amount of condensation may be as much as several liters per hour at high relative humidity. 
This is sometimes mistakenly regarded as a water leak.

Pressure gauge display (R410A

Examine the pressure gauge which indicates the refrigerant gas pressure of the unit, the below 
table shows the normal value of the gas pressure (R410A) when the machine is in power off or 
running conditions.

Unit Condition

Power Off

Ambient (°C)

-5 ~ 5

5 ~ 15

15 ~ 25

25 ~ 35

Water temp (°C)

/

/

/

/

Pressure gauge (Mpa)

0,68 ~ 0,93

0,93 ~ 1,25

1,25 ~ 1,64

1,64 ~ 2,1

Unit Condition

Running

Ambient (°C)

/

/

/

/

/

Water temp (°C)

10 ~ 15

15 ~ 20

20 ~ 25

25 ~ 30

30 ~ 35

Pressure gauge (Mpa)

1,3 ~ 1,8

1,5 ~ 1,9

1,6 ~ 2,3

1,9 ~ 2,8

2,1 ~ 3,5

Summary of Contents for XHPFD 100 E

Page 1: ...INVERTER SWIMMING POOL HEAT PUMP USER MANUAL Illustrative photo i Read the instructions EN VERZE 8 6 2017 REVIZE 3 11 2017...

Page 2: ...ol heat pump for your pool heating it will heat your pool water and keep the constant temperature when ambient temperature at 10 C to 35 C Regulation EU n 517 2014 of 16 04 14 on fluorinated greenhous...

Page 3: ...ump during winter time or when the ambient temperature drops below 0 C or else the Titanium exchanger will be damaged because of being frozen in such case your warranty will be lost WARNING Please alw...

Page 4: ...PH Std Current Input A 3 7 4 6 5 4 Maximum Current A 6 65 Minimum fuse A 18 18 18 Water in out connection mm 50 Fan quantity 1 Ventilation type Horizontal Compressor brand GMCC GMCC GMCC Compressor t...

Page 5: ...nt Input A 7 2 9 11 9 Maximum Current A 11 31 25 32 Minimum fuse A 31 Water in out connection mm 50 Fan quantity 1 2 Ventilation type Horizont ln Compressor brand MITSUBISHI MITSUBISHI PANASONIC Compr...

Page 6: ...s m3 h Voltage 380 V 50 Hz 3 PH 220 240 V 50 Hz 1 PH 380 V 50 Hz 3 PH Std Current Input A 5 1 14 9 6 4 Maximum Current A 15 40 18 Minimum fuse A Water in out connection mm 50 Fan quantity 2 Ventilatio...

Page 7: ...7 2 Dimension XHPFD 100 E XHPFD 160 E...

Page 8: ...ation please consult more instruction from technicians 6 When install a bypass it should be not exceed 30 of nominal flow rate 7 Must make Water level higher than the circulation pump location 8 Below...

Page 9: ...lose the valve direct 2 Make sure that the pump and the water in pipe have been filled with water 3 Start the unit 16 The location of chemical s instruction to your system is also critical to the heat...

Page 10: ...must be running to cause the water to circulate through the heat pump The heat pump will not start up if the water is not circulating After all connections have been made and checked carry out the fo...

Page 11: ...will trigger this time delay and prevent the unit from restarting immediately Additional power interruptions during this delay period do not affect the 3 minute duration of the delay Condensation The...

Page 12: ...6 2 button It will be under function only with other button 6 3 and button Clock unclock the display Hold and for 5 seconds to lock Unlock the display Water temperature setting Press or to set the wa...

Page 13: ...time All error code 6 9 Press first then press to check adjust the User parameter from P1 to P7 Parameter code Condition Range Default Remarks P1 Working mode 0 1 1 1 Heating mode 0 cooling mode P2 Ti...

Page 14: ...will flash When in Full output the lamp of Smart is lighting the lamp of Powerful will be flash 6 12 While you choose the Silent the heat pump will just operate in Medium output and Small output When...

Page 15: ...3 Smart 15 Powerful setT 1 Powerful 7 2 The Cooling operation logic Working status Working mode Water in temperature Heat pump working level 1 Start up of heat pump Smart setT 1 Standby 2 setT 1 a se...

Page 16: ...ve a specialised company change add refrigerant 2 Clean air heat exchanger 3 Replace the filter 4 Check and reconnect the electrical cables from the low pressure switch 5 Replace the low pressure swit...

Page 17: ...circuit breaker if it is connected LED wire controller displays the actual time Heat pump under standby status Startup heat pump to run LED wire controller displays the actual water temperature 1 Wate...

Page 18: ...Heating pipe temperature F Temperature of exhaust gases G Water out temperature H Water in temperature I Display Control J Water flow switch K Defrost switch L Low Pressure switch M High Pressure swit...

Page 19: ...ct A disconnect means circuit breaker fused or un fused switch should be located within sight of and readily accessible from the unit This is common practice on commercial and residential heat pumps I...

Page 20: ...20 11 Exploded view...

Page 21: ...pipes 11 Lead 36 High pressure switch 12 Drainage stopper 37 Low pressure switch 1 13 PC inverter board 38 Low pressure switch 2 14 Regulator box cover 39 Filter 16 Regulator box 40 Temperature senso...

Page 22: ......

Reviews: