Bright Technology cb958b User Manual Download Page 18

15 

 

You can execute the following step by step: 

[TES]    [ DYN]

( dynamic sensor test) 

[TES]    [ Dis]

 (test for the distance to the machine 

 

[TES]    [Dia] 

(test for the rim diameter

 

[TES]    [ Wid]

 (test for the rim breadth

 

By testing the above sensors, you can quickly find the 

trouble shooting point.   

After entering into

 [SET] [UP],

 do not enter the 

[TES]- 

[INT]

  program.  Press 

 

key,  you  can  enter  the 

customer weight marking

(CAL WEI)

 You can select this 

function when you consider the test result inaccurate or 

the machine not used for a long time. When you enter 

into this function, display will displa

y[ ADD] 

–[    ]-[ 0 ]-

   

and press 

  to start the machine for a time.   

 

 

This operation must be  executed after mounting the 

tire  or  rim  with  the  relative  small  unbalance  value  and 

input the correct value of the Dis, Bre and Dia

  Or you 

will cause the inaccurate measurement result.

 

When  rotate  the  wheel  to  test,  it  will  display 

[ADD] 

[    ]

–[100].

  Rotate  the  wheel  and  clip  a  piece  of 

standard  weight  of  100Gr  at  the  top  center  position 

when  the  entire  tire  unbalance  indicating  lamp  light. 

And start the machine once again, you can realize the 

self-calibration. This   

operation can make the machine fast restore its use of 

precision. 

****The shortcuts is located in the operation window not 

the  program  setup  window.  Press  and  hold  on 

 

key. Five seconds  later, the program will automatically 

enter  the  self-calibration  program  and  the  display  will 

display

  [ADD]-[  ] 

–[  0  ]-   

  The  other  operation  steps 

are similar to the above.   

If  need  to  enter  the  scale  self-calibration,  follow  the 

following steps

 

The  display  will  display  [CAL]-[WEI]-[CAL]  Press

 

to enter [CAL]- [RL1]-[    ] 

Enter  the  scale  calibration  program

[CAL]-  [RL1]- 

[    ]

(distance to the machine) Press 

  key to   

confirm  the  entrance  and  the  display  will  display 

[Dis]     

-[    ]-[ 0 ] 

Position  the  scale  to the  zero  position,  press 

  to 

confirm  and  the  display  will  display

  [Dia]-[    ]--[14]

Mount a medium size tire or rim on the main shaft and 

then,  according  to  the  diameter  of  the  rim  and  tire 

mounted on the shaft, press

 

 

  to adjust the 

14to  the  dimension  of  the  rim  mounted

change  the 

value on the right window from 14 to 16 if the diameter 
of the tire mounted is 16‖

  and then pull out the scale 

end  to  lean  it  against  the  edge  of  the  rim  and  at  the 

same  time  press 

  key  to  confirm.  Thus  we  have 

completed the automatic dis&dia scale calibration. 

****The shortcuts is located in the operation  window 

not  the  program  setup  window.  Press  and  hold  on 

  key.  Five  seconds  later,  the  program  will 

automatically enter the self-calibration program and the 

display  will  display 

[ADD]-[    ] 

–[  0  ]-

.  Then  press 

  and  the  display  will  display 

[CAL]

—[RL1]-[    ],

 

The other operation steps are similar to the above.   

If need to enter the    width scale self-calibrition  ,follow 

the following    steps 

The  display  will  display.

[CAL]-[RL1]-[    ]

    Press 

to  enter 

[CAL]-[RL2]-[    ]

  (Cale  width    ruller) 

Press

 

to confirm the entrance and the display will 

display

  [CAL]-[RL2]-[P0]

,Position  the  width  scale  to 

the  zero  position  press 

to confirm and display 

will  display

  [CAL]-[RL2]-[P1]

  ,and  Pull  out  the 

width scale end to lean it against the plan of the 

mainshaft and at the same time press 

key to 

confirm. 

Thus  we  have  completed  the  automatic  widthscale 

calibration. 

Summary of Contents for cb958b

Page 1: ...I...

Page 2: ...ERFORMANCE 4 3 1PERORMANCE CHARACTERISTIC 4 3 2MAIN TECHNICAL SPECIFICATION 4 3 3WORKING PRINCIPLE 5 4 TRANSPORTATION INSTALLATION 5 4 1TRANSPORTATION 5 4 2INSTALLATION 5 5 SAFETY PRECAUTIONS 6 6 CONF...

Page 3: ...AND WIRING 16 7 4 GENERAL TROUBLESHOOTING SOLUTION 18 7 5 STANDARD ACCESSORIES 19 8 MAINTENANCE 20 9 OPERATION DETAILED DESCRIPTION 23 HOW TO BALANCE A WHEEL 23 APPENDIX 1 LAYOUT OFTHE POWER SUPPLY CA...

Page 4: ...ation so as to allow the machine operators to consult the documentation at any time The manual is only to be considered valid for the machine serial number and model stated on the attached nameplate T...

Page 5: ...se the machine under the influence of alcohol or drugs that could affect his her physical and mental capacity The following conditions are essential read and understand the information and instruction...

Page 6: ...dicates the rotation direction Grounding symbol This decal positioned on the back of the machine indicates where to insert the power supply cable and warns the user to pay attention to his safety 2 IN...

Page 7: ...application of the stabilizer if the voltage of installation site is unstable WARNING Any electrical connect in the workshop is only done by the qualified technical staffs and it should meet the enfor...

Page 8: ...y and store the machine according to the indication of the label on the package carton Store environment RH20 95 temperature 10 60 When transport and use the machine do not pull the rotation shaft or...

Page 9: ...o be defect in any way 5 1 6 You should wear properly such as glove goggle and working suit You should not wear necktie long hair and loosen clothing The operator should stand beside the machine and t...

Page 10: ...Wheel B CE mark indicates that this model of machine has CE certification C SERIES NUMBER The first 3 digital is the abbreviation of the model of the machine and the middle 4 is the production date an...

Page 11: ...e window by press the up down key The default unit is inch When use the automatic scale it is no need for you to use this key and the machine will automatically access the diameter of the rim STA DYN...

Page 12: ...d clean the dust and mud and if there are foreign bodies such as metal stone clipped weights on the surface of the tyre or wheel And also check the air pressure of the tyre is according with the speci...

Page 13: ...display And now the display will display Br XXX And we can also adjust this value by rotating the tyre fixed on the main shaft 6 4 3 Input the Tire Diameter Value Dia After confirming the rim diamete...

Page 14: ...uter unbalance position 6 4 8 Add the corresponding weight at the unbalance point and start test again until the balance of the tyre CAUTION 1 When start the machine use hand to pull the wheel to help...

Page 15: ...t select the MOT function if the present scale can measure the value of dis And if the present scale can not measure the value of dis we need the extension scale to execute the dynamic balance First w...

Page 16: ...ide and outside unbalance value Rotate the wheel until the entire inside position indication lamps light up At this moment the D1 lamp will light Step the brake to stop the tire Pull out the scale and...

Page 17: ...er and then press key To confirm the entrance and the setup is similar to the above 7 1 4 SET APP light tire minimum unbalance setup You can setup 1Gr and 5Gr The setup is similar to the above 7 1 5 7...

Page 18: ...enter the scale self calibration follow the following steps The display will display CAL WEI CAL Press to enter CAL RL1 Enter the scale calibration program CAL RL1 distance to the machine Press key t...

Page 19: ...the phase sensor or the press sensor you must execute the self calibration When change the computer board you should setup the parameter according to the parameter marked in the machine or on the orig...

Page 20: ...lass glue coat on the surface of the press sensor and the normal installation result of the piezoelectric ceramics disk of the sensor is the IR should be larger than 50M 8 Discharge the output line of...

Page 21: ...change of value will be 20 90g 1 There are foreign bodies on the wheel or the unbalance of the wheel value too big 2 sensor damage 3 external power source voltage too low 1 Change the wheel 2 Check th...

Page 22: ...rom the use of non original spare parts or accessories Spring 1 Plastic Cap Protective Cover 1 Plastic Cap 1 Gauge Extension 1 OPTIONAL ACCESSORIES ACCESSORIES NAME ACCESSORIES NAME Guard Four Holes A...

Page 23: ...open up the bearing so you need insert a screwdriver to test the noise Due to the function of the bearing is to clamp and support and not suitable to change or remove the grease In addition the speed...

Page 24: ...d distributors set up proper collection and treatment systems for these products for this purpose Contact your local distributor to obtain information on the collection procedures at the end of the li...

Page 25: ...e to measure the Bre you can press to input the Br value which is the implied value with the unit of inch If you want to convert this value into the value with the unit of mm press to realize the conv...

Page 26: ...24 APPENDIX LAYOUT OF THE POWER SUPPLY CARD...

Page 27: ...25 APPENDIX Wiring Diagram...

Page 28: ...manufacturer is only responsible for the normal wear improper transportation or use and the maintenance without care Manufacturer will not notify the customers when improve the products and production...

Reviews: