why the use of salt is insignificant). If the disinfection takes place over night, the chlorine concentration
increases rapidly and the disinfectant effect is more effective.
It is also advisable to maintain the concentration of isocyanuric acid (chlorine stabilizer) around 35ppm,
ie 35 g/cbm of water. This concentration, although minimal, allows minimizing the diurnal losses of
chlorine through the effect of ultraviolet radiation.
5.6
Low Temperature Operation
Failure to comply with this procedure will invalidate any warranty of the equipment and the cell.
5.7
Operation with Pool Coverage
The production of chlorine when the pool is covered should be lower than when it is uncovered. If the
cover has an electrical control unit, it is possible to automate the process (see section 4.2.4). If the cover
is manual, the side switch should be in position “II” whenever the covered.
The cover detector reduces the electrolysis period for 10% of the filtering time.
6
Alarms
6.1
Alarm 1 – Low Flow
This alarm (ALARM 1) is triggered when the water flow entering the electrolysis cell is too low. The
system will automatically switch to standby mode to safeguard its integrity.
Check if:
•
all valves are in the correct position
•
there is water leakage in hydraulics
•
the filter is in the filtering position
•
the electrical switches are all connected
The alarm deactivates automatically once the problem is solved.
6.2
Alarme 2A – Hight Salt
This alarm (ALARM 2A) is released when the electrolysis reaches the maximum threshold of 130%. This
indicates that the salt concentration in the pool is above the maximum desirable to preserve the cell.
The amount of salt should be inferred by the water volume of the pool and reduced accordingly. In
alternative, the current can be adjusted to the new salt concentration (see 5.5.1).
Check if:
•
salt concentration is between 0,5 and 1,5 g/l
•
the salt is completely diluted in water
•
all valves are in the correct position
•
the power supply is well regulated
•
the equipment is correctly calibrated
Once the problem is corrected, reboot the equipment to deactivate the alarm.
When the water temperature is less than 12ºC, electrolysis production must be turned off to avoid
cell damage. The models with temperature probe included (ELECTRAL) this process is automatic.