28
Fig 9 – Menus Indicating Chlorine Production
It is possible to connect an external device to control the production of chlorine. To activate the external
controller, shift production to "EXT" mode.
Fig 10 – System Menu Controlled by External Equipment
5.2
Automatic Mode
In this operating mode the system calculates the chlorine production percentage needed according to
the water temperature, as listed below:
Temperature
Chlorine Production (%)
T >15ºC
100%
12ºC <T< 15ºC
50%
T< 12ºC
0%
Table 3 – Chlorine vs Temperature
5.3
Manual Mode
In the manual mode the user can specify the chlorine production as a percentage of the filtering time,
from 0% to 100%.
5.4
External Mode
The external mode applies if you want to connect ELECTRAL to an external controller. In this way, the
production of electrolysis is subject to the external equipment setup.
5.5
Recommendations for Disinfection
It is recommended that the disinfection is carried out overnight. Indeed, the ultraviolet radiation acting
on the free chlorine produced by the electrolysis cell, catalyses the regeneration of mineral salts (this is
Bright Blue is not responsible for errors or failures of the external equipment that have direct effect
on the quality and disinfection of pool water.
Automatic Production
Salt 100%
Manual Production 90%
Salt 100%
Cover Closed
Salt 100%
Production stopped by
external device
Production activated by
external device