Lubricate all connections shown below, following these
instructions:
1. Inspect and clean connecting surfaces prior to
lubrication and assembly.
2. Use lubricants sparingly during assembly; a light film
is all that is required.
3. Use a small brush or cotton swab to apply grease
directly to o-rings where they are not accessible (QC
fitting, M22 fitting).
Connect Hoses and Water Supply
NOTICE
Use ONLY cold water (less than 100°F).
1. Uncoil high pressure hose and attach black end of
hose to base of spray gun. Tighten by hand.
2. Attach blue end of high pressure hose to high
pressure outlet on pump. Tighten by hand.
3. Attach garden hose (50 ft. / 15.24 m maximum) to
water supply and run water through garden hose for
30 seconds to flush the hose of debris. Turn off water.
4. Confirm that water inlet screen (A) and black rubber
washer (B) is installed in water inlet coupling (C).
5. Attach water inlet coupling (C) to right side (viewing
from rear) of main unit as shown. Tighten by hand.
NOTICE
DO NOT run pump without water supply
connected and turned on.
• Damage to equipment resulting from failure to follow
this instruction will void warranty.
6. Attach garden hose (D) to water inlet coupling (C).
Tighten by hand.
Connect Nozzle Extension and 7-in-1
Nozzle
1. Turn ON water, point gun in a safe direction, press
trigger lock button (D), then squeeze trigger to purge
pump system and spray gun of air and impurities.
2. Attach nozzle extension to spray gun. Tighten by
hand.
3. Pull back on collar of nozzle extension, insert 7-in-1
nozzle and release collar. Tug on 7-in-1 nozzle to
make sure it is securely in place. See
How to Use
Nozzles
.
Servicing Of A Double-Insulated
Appliance
In a double-insulated product, two systems of insulation
are provided instead of grounding. No grounding means
is provided on a double-insulated product, nor should a
means for grounding be added to the product. Servicing
a double-insulated product requires extreme care and
knowledge of the system, and should be done only by
qualified service personnel. Replacement parts for a
double-insulated product must be identical to the parts
they replace. A double-insulated product is marked
with the words “DOUBLE INSULATION” or “DOUBLE
INSULATED.”
The symbol
means DOUBLE-INSULATED
APPLIANCE.
D
A
B
D
C