BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC EQUIPMENT OWNER WARRANTY POLICY

LIMITED WARRANTY

Briggs & Stratton Power Products Group, LLC will repair or replace, free of charge, any part(s) of the equipment that is defective in material
or workmanship or both. Transportation charges on product submitted for repair or replacement under this warranty must be borne by
purchaser. This warranty is effective for the time periods and subject to the conditions stated below. For warranty service, find the nearest
Authorized Service Dealer in our dealer locator map at www.briggspowerproducts.com.

THERE IS NO OTHER EXPRESS WARRANTY. IMPLIED WARRANTIES, INCLUDING THOSE OF MERCHANTABILITY AND FITNESS
FOR A PARTICULAR PURPOSE, ARE LIMITED TO ONE YEAR FROM PURCHASE, OR TO THE EXTENT PERMITTED BY LAW ANY
AND ALL IMPLIED WARRANTIES ARE EXCLUDED. LIABILITY FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES ARE EXCLUDED
TO THE EXTENT EXCLUSION IS PERMITTED BY LAW. Some states or countries do not allow limitations on how long an implied warranty
lasts, and some states or countries do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation
and exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other rights which vary from state
to state or country to country.

OUR EQUIPMENT*

OUTBOARD

MOTOR

PRESSURE

WASHER

WATER PUMP

(Not available in the

USA)

PORTABLE

GENERATOR

WELDER

L

Le

es

ss

s  tth

ha

an

n  1

10

0  K

KW

W

1

10

0  K

KW

W  o

orr  g

grre

ea

atte

err

T

Trra

an

ns

sffe

err  s

sw

wiittc

ch

h

2 years

none

1 year

90 days

1 year

90 days

2 years

1 year

2 years

none

3 years or

1500 hours

none

3 years

none

WARRANTY PERIOD**

HOME STANDBY GENERATOR SYSTEM

Consumer Use

Commercial Use

*

The engine and starting batteries are warranted solely by the manufacturers of those products.

**

2 years for all consumer products in the European Union. Parts only on 2nd year for consumer use of Portable Generator and
Home Standby Generator System - Less than 10 KW, outside of European Union.

The warranty period begins on the date of purchase by the first retail consumer or commercial end user, and continues for the period of time
stated in the table above. “Consumer use" means personal residential household use by a retail consumer. “Commercial use" means all other
uses, including use for commercial, income producing or rental purposes. Once equipment has experienced commercial use, it shall thereafter
be considered as commercial use for purposes of this warranty.

Equipment used for prime power in place of utility are not applicable to

this warranty. Electric powered pressure washers used for commercial purposes are not warranted.

NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS & STRATTON PRODUCTS. SAVE YOUR
PROOF OF PURCHASE RECEIPT. IF YOU DO NOT PROVIDE PROOF OF THE INITIAL PURCHASE DATE AT THE TIME WARRANTY
SERVICE IS REQUESTED, THE MANUFACTURING DATE OF THE PRODUCT WILL BE USED TO DETERMINE THE WARRANTY
PERIOD.

ABOUT YOUR WARRANTY

We welcome warranty repair and apologize to you for being inconvenienced. Any Authorized Service Dealer may perform warranty repairs. Most
warranty repairs are handled routinely, but sometimes requests for warranty service may not be appropriate. For example, warranty service would not
apply if equipment damage occurred because of misuse, lack of routine maintenance, shipping, handling, warehousing or improper installation.
Similarly, the warranty is void if the manufacturing date or the serial number on the equipment has been removed or the equipment has been altered
or modified. During the warranty period, the Authorized Service Dealer, at its option, will repair or replace any part that, upon examination, is found to
be defective under normal use and service. This warranty will not cover the following repairs and equipment:

Normal Wear:

Outdoor Power Equipment, like all mechanical devices, needs periodic parts and service to perform well. This warranty does not

cover repair when normal use has exhausted the life of a part or the equipment.

Installation and Maintenance:

This warranty does not apply to equipment or parts that have been subjected to improper or unauthorized

installation or alteration and modification, misuse, negligence, accident, overloading, overspeeding, improper maintenance, repair or storage so as,
in our judgment, to adversely affect its performance and reliability. This warranty also does not cover normal maintenance such as adjustments,
fuel system cleaning and obstruction (due to chemical, dirt, carbon, lime, etc.).

Other Exclusions:

This warranty excludes wear items such as quick couplers, oil gauges, belts, o-rings, filters, pump packing, etc., pumps that

have been run without water supplied or damage or malfunctions resulting from accidents, abuse, modifications, alterations, or improper servicing
or freezing or chemical deterioration. Accessory parts such as guns, hoses, wands and nozzles are excluded from the product warranty. This
warranty excludes failures due to acts of God and other force majeure events beyond the manufacturers control. Also excluded is used,
reconditioned, and demonstration equipment; equipment used for prime power in place of utility power and equipment used in life support
applications. 

BRIGGS & STRATTON POWER PRODUCTS GROUP, LLC

JEFFERSON, WI, USA

Effective September 1, 2004 replaces all undated Warranties and all Warranties dated before September 1, 2004

Summary of Contents for 30253

Page 1: ...el Generador 1 800 743 4115 M F 8 5 CT web www briggsandstratton com BRIGGS STRATTON POWER PRODUCTS GROUP LLC JEFFERSON WISCONSIN U S A Manual No 198171GS Revision 1 11 14 2005 Before using this produ...

Page 2: ...on refer to the engine operator s manual SAFETY RULES This is the safety alert symbol It is used to alert you to potential personal injury hazards Obey all safety messages that follow this symbol to a...

Page 3: ...less colorless poison gas Breathing carbon monoxide can cause nausea fainting or death WARNING WHEN ADDING OR DRAINING FUEL Turn generator OFF and let it cool at least 2 minutes before removing fuel c...

Page 4: ...ent sparks smokes or emits flames unit vibrates excessively Improper treatment of generator can damage it and shorten its life CAUTION WHEN ADJUSTING OR MAKING REPAIRS TOYOUR GENERATOR Disconnect the...

Page 5: ...peration of 120 and or 240 Volt AC 30 Amp single phase 60 Hz electrical lighting appliance tool and motor loads Air Cleaner Protects engine by filtering dust and debris out of intake air Choke Lever U...

Page 6: ...lign the handle so it will slide over the handle supports 2 Insert carriage bolts through holes from outside of the unit and attach a plastic knob from inside of unit Figure 2 Tighten by hand BEFORE S...

Page 7: ...fuel gauge to close it Figure 4 IMPORTANT The vent knob should be closed whenever you move the generator or transport the fuel tank WHEN ADDING FUEL Turn generator OFF and let it cool at least 2 minut...

Page 8: ...l tank MUST be filled with it lying flat not slanted or standing upright Figure 9 DO NOT let the fuel valve and quick connect come in contact with any dirt To place the fuel tank back on the unit foll...

Page 9: ...a confined area Figure 10 Prevailing winds and air currents should be taken into consideration when positioning generator When using generator for backup power notify utility company Use approved tra...

Page 10: ...oad Generator Start generator and let engine stabilize before connecting electrical loads Connect electrical loads in OFF position then turn ON for operation Turn electrical loads OFF and disconnect f...

Page 11: ...up to 2 775 watts of power at 23 1 Amps for 120 Volts 5 550 watts of power 5 55 kW at 23 1 Amps for 240 Volts The outlet is protected by a push to reset circuit breaker 120 Volt AC 20 Amp Duplex Recep...

Page 12: ...to stabilize engine runs smoothly and attached device operates properly 4 Plug in and turn on the next load 5 Again permit the generator to stabilize 6 Repeat steps 4 and 5 for each additional load N...

Page 13: ...lean generator Water can enter engine fuel system and cause problems In addition if water enters generator through cooling air slots some of the water will be retained in voids and cracks of the rotor...

Page 14: ...Figure 5 earlier To prevent gum from forming in fuel system or on essential carburetor parts empty entire contents of both supplied fuel stabilizer containers into fuel tank and fill with fresh fuel...

Page 15: ...it in a connected load 2 Generator is overloaded 3 Shorted generator circuit 1 Disconnect shorted electrical load 2 See Don t Overload Generator 3 Contact local service facility Engine will not start...

Page 16: ...16 NOTES NOTES...

Page 17: ...ectric powered pressure washers used for commercial purposes are not warranted NO WARRANTY REGISTRATION IS NECESSARY TO OBTAIN WARRANTY ON BRIGGS STRATTON PRODUCTS SAVE YOUR PROOF OF PURCHASE RECEIPT...

Page 18: ...t le California Air Resources Board Pour des informations sur la garantie se reporter au manuel d utilisation du moteur R GLES DE S CURIT Ceci est la s ret le symbole vif Il est utilis pour vous alert...

Page 19: ...e g n rateur et laissez le refroidir au moins 2 minutes avant de retirer le capuchon du r servoir de carburant Desserrez lentement le capuchon pour laisser la pression s chapper du r servoir Remplisse...

Page 20: ...ivement Un traitement inappropri du g n rateur risque de l endommager et de raccourcir sa dur e d utilisation ATTENTION LORSQUE VOUS R GLEZ OU R PAREZ VOTRE G N RATEUR D branchez toujours le c ble de...

Page 21: ...service Filtre air Utilise un l ment de filtre du type sec et un pr filtre en mousse pour limiter le montant de salet et de poussi res entrant dans le moteur Fixation de mise la masse Consultez l agen...

Page 22: ...n e d un c t l autre afin d aligner la poign e et de la faire glisser sur les supports 2 Ins rez le boulon dans le trou du c t droit de la poign e en regardant l arri re de l appareil et fixez le bout...

Page 23: ...s des aiguilles d une montre sur la jauge pour le fermer Figure 17 IMPORTANT Le bouton d a ration doit tre ferm chaque fois que vous d placez le g n rateur ou transportez le r servoir LORS DE L AJOUT...

Page 24: ...DOIT tre rempli lorsqu il est plat il ne doit pas tre inclin ou en position verticale Figure 22 NE LAISSEZ PAS la valve et le connecteur rapide en contact avec des salet s Pour replacer le r servoir...

Page 25: ...oment de choisir l endroit o vous installerez la g n ratrice Lorsque vous utilisez le g n rateur comme source d nergie de secours il est n cessaire d aviser les services publics d lectricit Utilisez u...

Page 26: ...s remettez en position MARCHE teignez les charges lectriques et d branchez les du g n rateur avant de l arr ter D passer la capacit de puissance ou d amp rage du g n rateur risque d endommager ce dern...

Page 27: ...cessitant jusqu 2 775 watts de puissance 2 775 kW 23 1 Amp res pour 120 Volts 5 550 watts de puissance 5 55 kW 23 1 Amp res pour 240 Volts La prise est prot g e par un disjoncteur de 30 Amp res du ty...

Page 28: ...tabiliser le moteur tourne r guli rement et les dispositifs branch s fonctionnent correctement 4 Branchez et mettez la charge suivante en marche 5 De nouveau laissez le g n rateur se stabiliser 6 R p...

Page 29: ...des probl mes De plus si l eau entre par les fentes de refroidissement air une partie de l eau restera dans les creux et craquelures de l isolation du bobinage du rotor et du stator L eau et l accumu...

Page 30: ...on de gomme dans le syst me d alimentation en carburant ou sur des pi ces essentielles du carburateur videz les trois r cipients de stabilisateur d essence fournis dans le r servoir et remplissez les...

Page 31: ...e en court circuit 2 Voir Ne Pas Surcharger G n rateur 3 Contacter n gociant de service Autoris Le moteur ne veut pas d marrer ou d marre et marche mal 1 La valve est en position Arr t 2 Le bouton d a...

Page 32: ...REMARQUES 32 REMARQUES...

Page 33: ...BRIQU PAR BRIGGS STRATTON IL N EST PAS N CESSAIRE DE L ENREGISTRER CONSERVEZ LE RE U COMME PREUVE D ACHAT SI LORS D UNE R CLAMATION DE GARANTIE VOUS NE POUVEZ PROUVER LA DATE INITIALE DE L ACHAT NOUS...

Page 34: ...i n Ambiental y el Consejo de recursos de aire de California Para mayor informaci n acerca de la garant a consulte con el Manual del Operario de Motor REGLAS DE SEGURIDAD ste es el s mbolo de alerta d...

Page 35: ...silenciador el tap n del dep sito de combustible y el filtro de aire est n instalados NO arranque el motor sin la buj a instalada Si se ha derramado combustible espere a que se evapore antes de arran...

Page 36: ...produce chispas humo o emite llamas La unidad vibra de una manera excesiva El tratamiento inadecuado del generador puede da arlo y acortar su vida productiva PRECAUCI N CUANDO AJUSTE O HAGA REPARACION...

Page 37: ...En para darle arranque al motor Col quelo en la posici n Off Apagado para detener un motor en funcionamiento Palanca del Cebador Usada cuando se est dando arranque a un motor fr o Pomo de Ventilaci n...

Page 38: ...a deslizarse sobre los soportes del mismo manubrio 2 Inserte el perno del soporte a trav s de los orificios desde interior de la unidad y sujete una perilla de pl stico desde el fuera de la misma unid...

Page 39: ...ustible Figura 30 IMPORTANTE Siempre que mueva el generador o traslade el dep sito de combustible el pomo de ventilaci n debe estar cerrado MONTAJE 39 Combustible Tanque Espacio de 1 5 Figura 29 Espac...

Page 40: ...orizontal no inclinado ni en posici n vertical Figura 35 Evite el contacto de la v lvula de combustible y del conector r pido con la suciedad Para volver a montar el dep sito de combustible en la unid...

Page 41: ...erador Cuando use un generador como poder de energ a auxiliar notifique a la compa a de utilidades Use el equipo de transferencia aprobado para aislar el generador de otra utilidad el ctrica Use un in...

Page 42: ...tricas Conecte las cargas el ctricas en la posici n de apagado OFF luego encienda ON para su operaci n Apague OFF las cargas el ctricas y descon ctelas del generador antes de parar el generador El sob...

Page 43: ...para 120Voltios 5 550Voltios de energ a 5 55 kW a 23 1 Amperios para 240Voltios La salida est protegida por un corto circuito de del tipo empuje para reposicionar 120 Volt AC 20 Amp Recept culos Dobl...

Page 44: ...onectado al mismo trabaja adecuadamente 4 Conecte y encienda la pr xima carga 5 De nuevo permita que el generador se estabilice 6 Repita los pasos 4 y 5 para cada carga adicional que usted tenga NUNCA...

Page 45: ...amos el uso de mangueras de jard n para limpiar el generador El agua podr a introducirse en el sistema de combustible del motor y causar problemas Adem s si el agua se introduce al generador a trav s...

Page 46: ...Off Figura 31 Para evitar la formaci n de carbonilla en el circuito de combustible o en piezas esenciales del carburador vac e totalmente los contenedores de estabilizador de combustible en el dep si...

Page 47: ...ecarga 3 Circuito del generador en corto 1 Desconecte la carga el ctrica en corto 2 Vea No Sobrerecarque Generador 3 Contacte el distribuidor de servicio autorizado El motor no se enciende o se encien...

Page 48: ...RVICIO DE BRIGGS STRATTON PRODUCTS GUARDE SU RECIBO DE COMPRA SI NO APORTA LA PRUEBA DE LA FECHA DE COMPRA INICIAL SE UTILIZAR LA FECHA DE FABRICACI N DEL PRODUCTO PARA DETERMINAR EL PER ODO DE GARANT...