57-DVRS50
14
Installation Instructions Cont.
VENTING
Clearance to combustibles
The following clearances must be maintained around the vent pipe:
Vertical runs:
1”
Horizontal runs:
2” on top, 1” sides and bottom
IMPORTANT:
This appliance venting system is a sealed system (DV), which means that all combustion
air is supplied from outdoors and the combustion products are exhausted to the outdoors.
Note
:
Only venting systems listed in this manual may be used with the model 57-DVRS50
Planning your vent installation
This type of direct vent system may terminate in one of two ways: vertical termination using a vent cap, or
horizontally using a wall termination. There are limitations to the vertical and/or horizontal lengths (see
page 18 for venting chart).
When calculating the length of the vent pipe from the outlet of the appliance to termination, allowing for
ceiling thickness, the vertical rise in the attic or second story and sufficient vertical height above the roof.
Fire stops are required at each floor level the vent passes through.
The following vent systems are certified for use with the model 57-DVRS50
If for any reason the vent pipe is disconnected it must be correctly resealed
Fig 14-A
Manufacturer Vertical Termination
Adapter
Archgard
999-DV-8HTCL (Direct connect to unit)
999-DV-8HTCLT ( Flex connect to unit)
N/A
Dura Vent
??? - Co-Axial Cap (requires adapter)
??? - Co-Axial High Wind (requires adapter)
58DVA-MG
ICC/Excel
?? - Co-Axial (requires adapter)
???- Co-Axial (requires adapter)
Ameri-vent
DVC - Co-Axial Cap (requires adapter)
Selkirk
Direct Temp DV Venting
5DT-AA Series
2-ply Aluminum
5” x 8” 2-ply Listed Aluminum Flexible pipe
A T T E N T I O N
NO OTHER VENTING SYSTEM OR COMPONENTS MAY BE USED.
Follow manufacturer instructions
for installation of termination.
The listed chimney vent systems use a twist lock connection. Assemble the vent system using the de-
sired combination of sections and elbows for your installation. Make sure you fully insert and twist the
mating sections all the way to make a solid connection.
Install as per manufactures instructions
Summary of Contents for 57-DVRS50
Page 8: ...57 DVRS50 8 APPLIANCE DIMENSIONS Surround Removed Surround Attached...
Page 27: ...57 DVRS50 27 REMOTE CONTROL SETUP AND OPERATION future option...
Page 28: ...57 DVRS50 28 REMOTE CONTROL SETUP AND OPERATION cont Future Option N A on this unit...
Page 29: ...57 DVRS50 29 REMOTE CONTROL SETUP AND OPERATION cont...
Page 30: ...57 DVRS50 30 REMOTE CONTROL SETUP AND OPERATION cont...
Page 31: ...57 DVRS50 31 REMOTE CONTROL SETUP AND OPERATION cont...
Page 33: ...57 DVRS50 33 REMOTE CONTROL SETUP AND OPERATION cont...
Page 35: ...57 DVRS50 35 CONVERSION KIT INSTRUCTIONS con t Step 7 Valve Conversion...
Page 39: ...57 DVRS50 39 WIRING SCHEMATICS Figure 25...
Page 42: ...57 DVRS50 42 NOTES...
Page 45: ...ARCHGARD INDUSTRIES 7116 Beatty Drive Mission B C V2V 6B4 Canada Website www archgard com...