35-DVRS31N
43
I M P O R T A N T
For high altitude installations above 4500 ft (1372 meters), consult local gas distributor or the authority having jurisdiction for proper de-
rating methods.
CONVERT THE GAS VALVE
CONVERSION KIT INSTRUCTIONS, cont.
COMPLETE THE CONVERSION
Turn on the gas and electrical supplies and check for leaks at
all
connections.
Turn on the fireplace so the burner is on.
Test inlet and outlet pressure. Visually check pilot flame. Flame should envelope top
of the flame sensor and extend forward onto the burner. Adjust pilot if required.
Turn fireplace off.
Affix Gas Type label to the rating plate label and Conversion Label
Complete the conversion label and affix to valve assembly plate.
Re-install the burner, media and shield.