35-DVRS31N
42
LP has hole
and red dot
CONVERSION KIT INSTRUCTIONS
The installation is not proper and complete until operation of the converted appliance is checked as specified in the instructions sup-
plied with the kit. Refer to appliance owner’s manual or product data plate for proper inlet and manifold pressure adjustments and ori-
fice sizing.
PREPARE THE FIREPLACE
Remove the surround, glass door assembly, and media
Remove the burner shield and burner
KIT NUMBERS:
35-CKE50LP
for LP gas and
35-CKE50NG
for Natural Gas
KIT INCLUDES:
1- Gas conversion label (303-0128)
1- Burner orifice (301-0068) (#51 DMS for LPG) (#35 DMS for NG)
1- Instruction Sheet
1- SIT 885 Valve conversion regulator c/w instructions & gas type label (0.907.015) LPG
(0.907.023) NG
PILOT CONVERSION
Using a 7/16” wrench, loosen the pilot hood a 1/4”
turn. Slide the tab at the bottom of the orifice hood all
the way so the red side (propane) with the hole in it is
showing. Tighten the pilot hood back up so that it is
lined up with the two probes on both sides of the pilot
assembly.
F O R Y O U R S A F E T Y
SHUT OFF GAS SUPPLY AND ELECTRICAL POWER TO FIREPLACE BEFORE BEGINNING THE GAS
CONVERSION
Remove the burner orifice using a 1/2” wrench. Replace with the orifice supplied with the conversion
kit. Use a small amount of pipe sealant on the threads of the orifice holder.
Fig. 41-A
Natural Gas
Fig. 41-B
Wrench here
Fig. 41-C
W A R N I N G
The conversion kit shall be installed by a qualified service agency in accordance with the manufacturers instructions and all applicable
codes and requirements of the authority having jurisdiction. If the information in these instructions is
not
followed exactly, a fire, explo-
sion or productions of carbon monoxide may result, causing property damage, personal injury or loss of life. The qualified service
agency is responsible for proper installation of this kit.
I M P O R T A N T
This fireplace is Natural gas ready. If converting to LP gas, follow instructions below